Mahatma Gandhi University
- AOC value
- ₹31.86L
- AOC date
- 2 Dec
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- 2 Dec 22AOC date
- -Published
- -Closes
- -Bid opens
- 2 Dec 2022AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- 02/12/2022
- Authority
- Mahatma Gandhi University
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Mahatma Gandhi University has published Flow Cytometer Analyzer Supply And Installation Of The Scientific Equipment Flow Cytometer Analyzer , Flow Cytometer Analyzer , ( A ) Specification For Flow Cytometer Analyzer ( I ) The Flow Cytometer Analyzer Should Be Compact, Transportable, Automated & Bench Top With A Blue Laser ( 488 Nm ) & Red Laser ( 640 Nm ) . All Lasers & Their Excitation & Collection Optics Should Be Fixed & Pre-Aligned. ( Ii ) The System Should Have The Capability Of Four Fluorescence Detectors And Two Light Scatter Detectors ( Forward & Side Scatter ) With Six Parameters Measurement. ( Iii ) The Flow Cytometer System Should Be Based On Hydrodynamic Focusing On The Laminar Flow Within The Flow Cell ( Quartz ) . ( Iv ) The System Should Have Pre-Optimized Detector Settings. Pmt Detectors Should Be Provided Standard Along With The System. ( V ) The Flow Cytometer Should Have The Capability Of User-Changeable Optical Filters. ( Vi ) The System Should Be Able To Detect A Minimum Particle Size Of 0.5 Micron And Capable Of Aspirating Samples With Volumes Of A Minimum Of 50Ul. ( Vii ) The System Should Have A Data Acquisition Speed 10, 000 Events Per Sec. ( Viii ) The System Should Accommodate A Wide Range Of Sample Input Tubes In Manual Loading With Various Sizes Of Microcentrifuge Tubes, 12X75 Mm Or Smaller Sample Tubes Made Of Polypropylene Or Polystyrene, 48 / 96Well Plates ( Flat, Round And V-Bottom ) And 96 Well Deep-Well Plates. ( Ix ) System Should Be Able To Perform Absolute Counting Without Adding Beads To The Samples. ( X ) The System Should Have Fluorescence Sensitivity Of At Least Mesf Fitc <75; Pe <50 ( Xi ) The System Should Have 18-Bit Or Higher Signal Processing, And Digital Data Should Be Collected With A 5-7-Decade Dynamic Range ( B ) Software & Data Management The System Should Come With Suitable Software For Acquisition And Data Analysis For All Applications. Should Quote For Both Online & Offline Compensation Software For Data Analysis. Design Should Be Compatible With Bead Array Applications. The Company Should Provide All The Software Updates For The Next Three Years For The System. Data Management System: All In One Pc Workstation With The Latest Workstation & Suitable Monitor. ( C ) A Startup Kit Should Be Provided Along With The Equipment For Safe Installations & Demonstrations Of The Instrument ( D ) 5Kv Ups With A Minimum Of Two Hours Backup For Working The Instrument In Emergencies.. Last date of submission for this tender is 2022-07-15. This is a Safes tender in Kottayam, Kerala
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
7 issued- Tender Document 1htmlHTML document
- Tender Document 2pdfPDF document
- Tender Document 3xlsxXLSX document
- Tender Document 4pdfPDF document
- Tender Document 5pdfPDF document
- Tender Document 6pdfPDF document
- Tender Document 7pdfPDF document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free