🎉 Your free trial plan has started. Plan will expire in 0 days

Kerala State Electricity Board

ernakulam, kerala

AOC value
₹2.93Cr
AOC date
6 Jul
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 6 Jul 24AOC date

Important info

Result ID
Refer Docs
Award of contract
06/07/2024
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Kerala State Electricity Board has published Supply, Installation, Testing And Commissioning Ofstrong Motion Accelerograph, Broad Band Seismograph & Communication System At Idamalayar, Sholayar And Poringalkuthu - Supply, Installation, Testing And Commissioning Of Strong Motion Accelerograph, Broad Band Seismograph And Communication System At Idamalayar, Sholayar And Poringalkuthu , For Supply Of Goods , Broad Band Seismograph ( Seismometer With Data Acquisition & Communication System, Including Software And All Components & Accessories ) For Field Stations ( Observatories ) Conforming To The Requirements Specified In Technical Specification.The System Shall Include Lightning Protection For The Observatory Building, Indoor Type Surge Protectors On Panel Board, Earthing With All Connectors As Per Relevant Standards, Etc Complete As Per Specifications , Strong Motion Accelerograph ( Accelerometer With Data Acquisition & Communication System Including Software And All Components & Accessories ) For Field Stations ( Observatories ) , Dam Crest / Free Field And Galleries Conforming To The Requirements Specified In Technical Specification.The System Shall Include Indoor Type Surge Protectors And Other Accessories Etc As Per Specifications With Necessary Weather Proof Enclosures Etc For Data Acquisition And For The Protection Of All Components. , Vsat System For Field Stations ( Observatories ) Including; • Odu ( Antenna With Transceiver ) . • Idu. • Ac Adapter. • Dc Adapter. • Ethernet Cable, Connectors Etc. Conforming To The Requirementsspecified In Technical Specification.The System Shall Include Indoor Type Surge Protectors And Other Accessories Etc As Per Specifications. , Solar Power System For Field Stations ( Observatories ) As Primary Power System Including Solar Panels, Charge Controller, Battery And All Cables, Cable Connectors, Mounting Racks, Indoor Type Surge Protection Devices And Any Other Accessories Conforming To The Requirements Specified In Technical Specification. , Secondary Power System For The Broad Band Seismographs At Field Stations ( Observatories ) Including Battery, Stabilizer, Battery Charger, Indoor Type Surge Protection Devices And Any Other Accessories, Conforming To The Requirements Specified In Technical Specification. , Secondary Power System For The Strong Motion Accelerographs At Field Stations ( Observatories ) Including Battery, Stabilizer, Battery Charger, Indoor Type Surge Protection Devices And Any Other Accessories, Conforming To The Requirements Specified In Technical Specification. , Secondary Power System For Vsat At Field Stations ( Observatories ) Including Battery, Stabilizer, Battery Charger, Indoor Type Surge Protection Devices And Any Other Accessories Conforming To The Requirements Specified In Technical Specification. , Power System For The Strong Motion Accelerographs At Various Installation Locations In Dam Crest / Free Field And Galleries By Extending Cables ( From The Main Ksebl Supply Point Including Providing A Common Control Switch At Starting Point ) Using 2.5 Mm2, 3 Core Armoured Cable With All Accessories And Including Battery For Back Up, Stabilizer & Battery Charger ( Ip 67 Rating ) With Spike Protection / Dc-Dc Converters, And Any Other Accessories, Conforming To The Requirements Specified In Technical Specification. , Desktop Computer For Control Room In Dam Safety Organisation Building, Pallom For Data Acquisition And Analysis Including Necessary Softwares And All Accessories Conforming To The Requirements Specified In Technical Specification. , Laptop For The Field ( Idamalayar, Sholayar And Poringalkuthu Field Offices ) Including Software And All Accessories Conforming To The Requirements Specified In Technical Specification. , For Related Services , Installation, Testing, Commissioning Of Broad Band Seismograph ( Seismometer With Data Acquisition& Communication System With Ksebl’S Crs Provided Etc. ) In Field Stations ( Observatories ) Conforming To The Requirements Specified In Technical Specifications, Providing Lightning Protection For The Observatory Building With Horizontal Conductors Above The Roof With Aluminium Strips 25 X 3 Mm Along The Outer Periphery Of The Building, Down Conductors And Plate Earthing At Two Locations, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works And Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing, Commissioning Of Strong Motion Accelerograph ( Accelerometer With Data Acquisition & Communication System With Ksebl’S Crs Provided Etc. ) In Field Stations ( Observatories ) , Dam Crest / Free Field And Galleries Conforming To The Requirements Specified In Technical Specifications, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works, Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge , Installation, Testing And Commissioning Of Vsat Systemfor Field Station ( Observatory ) Conforming To The Requirements Specified In Technical Specifications, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works And Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Solar Power System For Field Stations ( Observatories ) As Primary Power System Including Solar Panels, Charge Controller, Battery And All Cables, Cable Connectors, Mounting Racks And Any Other Accessories Conforming To The Requirements Specified In Technical Specifications, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works And Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Secondary Power System For The Broad Band Seismographs At Field Stations ( Observatories ) Including Battery, Stabilizer, Battery Charger And Any Other Accessories, Conforming To The Requirements Specified In Technical Specifications, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works And Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Secondary Power System For The Strong Motion Accelerographs At Field Stations ( Observatories ) Including Battery, Stabilizer, Battery Charger And Any Other Accessories, Conforming To The Requirements Specified In Technical Specifications, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works And Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Secondary Power System For Vsat At Field Stations Including Battery, Stabilizer, Battery Charger And Any Other Accessories Conforming To The Requirements Specified In Technical Specifications, Providing Indoor Type Surge Protection Devices ( Spd ) On Panel Board, All Related Civil Works And Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Power System For The Strong Motion Accelerographs At Various Locations ( In Dam Crest / Free Field And Galleries ) Including 2.5 Mm2, 3 Core Armoured Cable, Control Switches, Battery, Stabilizer & Battery Charger ( Ip67 Rating ) With Spike Protection / Dc-Dc Converters, Providing Crossings For Cables ( Wherever Necessary ) And With All Other Accessories, All Related Civil And Electrical Works, Providing Necessary Training, Documentation Conforming To The Technical Specifications And Conditions Of Contract Etc Complete As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Desktop Computer At Control Room In Dam Safety Organisation Building, Pallom With Necessary Softwares Etc Complete Conforming To The Requirements Specified In Technical Specifications, And Providing Necessary Training As Directed By The Engineer In Charge. , Installation, Testing And Commissioning Of Laptop With Necessary Softwares Etc Complete Conforming To The Requirements Specified In Technical Specifications, And Providing Necessary Training As Directed By The Engineer In Charge. , Integrating The Data Obtained From The Newly Added Seismic Equipments With The Existing Ksebl Network System Of Seismic Equipments And Connected Crs At Thiruvananthapuram, Making Arrangements To Obtain All Seismic Datas Received At Crs, Thiruvananthapuram In The Desktop Computer Installed At The Control Room In Dam Safety Organisation Building, Pallom Via The Seed Link Or Any Other Alternative Methods. The Work Includes Installation Of All Necessary Softwares Etc As Directed By The Engineer In Charge. , Recurring Expenditure For Vsat ( For Five Years ) , In Route: 36 Kbps Tdma In Route Bandwidth For Total Networking Including Dot & Wpc Share For Total Network. , Out Route: 16 Kbps Tdma Satellite Bandwidth Charges For Total Network Including Dot And Wpc Revenue Share And Vsat Network Monitoring Charges For Total Network. , Backhaul Connectivity: 24 Kbps Scpc Satellite Bandwidth Link Charges For Ksebl Including Dot And Wpc Revenue Share And Vsat Network Monitoring Charges For Total Network. , Camc Charges Of Entire System Including Seismic Equipment, Data Acquisition & Communication System, Maintenance Of Computers, Maintenance Related With Integration Of Data With The Crs System At Thiruvananthapuram And Obtaining All Seismic Data From Crs, Thiruvananthapuram In The Desktop Computer At Control Roomin Dam Safety Organisation Building, Pallom, Vsat System ( Including Spare Parts, Modules, Cards, Subunits, Consumables, Idu, Odu, Modem, Routers, Antennas, Cables, Connectors, Spds, Field Visit Charges, Providing Training, Repairing Charges, Transportation, Maintenance Cost Of Entire System Including That Of Related Civil Works ) Lightning Protection, Earthing And Surge Protection Etc. Completefor Year I After Warranty Period. , Camc Charges Of Entire System Including Seismic Equipment, Data Acquisition & Communication System, Maintenance Of Computers, Maintenance Related Withintegration Of Data With The Crs System At Thiruvananthapuram And Obtaining All Seismic Data From Crs, Thiruvananthapuram In The Desktop Computer At Control Roomin Dam Safety Organisation Building, Pallom, Vsat System ( Including Spare Parts, Modules, Cards, Subunits, Consumables, Idu, Odu, Modem, Routers, Antennas, Cables, Connectors, Spds, Field Visit Charges, Providing Training, Repairing Charges, Transportation, Maintenance Cost Of Entire System Including That Of Related Civil Works ) Lightning Protection, Earthing And Surge Protection Etc. Completefor Year Ii After Warranty Period. , Camc Charges Of Entire System Including Seismic Equipment, Data Acquisition & Communication System, Maintenance Of Computers, Maintenance Related Withintegration Of Data With The Crs System At Thiruvananthapuram And Obtaining All Seismic Data From Crs, Thiruvananthapuram In The Desktop Computer At Control Roomin Dam Safety Organisation Building, Pallom, Vsat System ( Including Spare Parts, Modules, Cards, Subunits, Consumables, Idu, Odu, Modem, Routers, Antennas, Cables, Connectors, Spds, Field Visit Charges, Providing Training, Repairing Charges, Transportation, Maintenance Cost Of Entire System Including That Of Related Civil Works ) Lightning Protection, Earthing And Surge Protection Etc. Completefor Year Iii After Warranty Period.. Last date of submission for this tender is 2023-11-02. This is a Accelerometers tender in Ernakulam, Kerala

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

7 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
  • Tender Document 7pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in