🎉 Your free trial plan has started. Plan will expire in 0 days

Kerala State Council For Science Technology And Environment

Scientific Instrument
peechi, kerala
AOC Value₹37.78 Lac
AOC Date05 Jan 2026
Completion DaysRefer Docs
Bid AmountRefer Docs

Important Info

Result ID
Refer Docs
Award of Contract
05/01/2026
Authority
Kerala State Council For Science Technology And Environment
Published Date
Refer Docs
Tender Closing Date
Refer Docs
Tender No
Bidding URL
Tender
Bidder Details

AOC Description

Kerala State Council For Science Technology And Environment has published Tender for Elemental Analyser For Automatic Determination Of C-H-N-S , Elemental Analyser For Automatic Determination Of C-H-N-S (Chns Analyser) , Fully Automated Pc Controlled Elemental Analyser With Following Specifications For Analysing Solid And Liquid Samples 1 Instrument Sample Weight Range 0.1 To 1000 Mg Or Better. Measuring Range 0.01% To 100% For All Elements. Also Mention The Absolute Measuring Range Of All Elements With Proof Standard Deviation =0.1% Of Absolute Measurement Time =10 Minutes In Chns Mode Controller Must Be Equipped With Electronic Mass Flow Controller And Digital Flow Sensors For Accurate Readout Of Flow Pressure And Flow Sensors All Pressure And Flow Sensors Must Be Electronic For Better Accuracy. There Should Be No Analogue Pressure Gauges. Flow Meters On The Analyser Must Be Computer Controlled. Kit For The Measurement Of Fluorinated Samples. 2. Furnace System Furnace Should Have Two Zone Furnace System, Separate For Combustion And Reduction With Independent Temperature Control For Each Furnace. Temperature Controlled Furnace Temperature Should Be 11000C Or More. Documentary Proof Needs To Be Attached Additional Features Should Have Possibility To Use Ceramic/Quartz Ash Finger To Handle High Inorganic/Halogen Or Fluorine Contents Sample. Warranty 10-Years Free Replacement Warranty On The Furnace 3. Separation System Separation Advanced Chromatographic Separation Of Gases. Full Separation Of All Analytes And There Should Be No Peak Tailing Or Peak Overlap. Sulphur Being A Crucial Element, Should Be Analysed With Higher Column Temperature (Separation Column) Than Nitrogen, Carbon, And Hydrogen. All Necessary Accessories/ Options In This Regard Should Be Quoted As Mandatory Items. 4. Autosampler System Sampler System Electrical Auto Sampler System With 60 Positions Or More. Pneumatic Auto-Sampler Is Not Acceptable. Requirement Zero Blank Sample Injection System 5. Detector System Detector Oxygen Intrusion Free Thermistor Technology-Based T. Last date of submission for this tender is 2025-11-17. This is a Scientific Equipment tender in Peechi, Kerala

Insurance Surety Bond

Fast, Reliable & Accepted for EMD/PBG

  • Zero BG Limit Impact
  • Accepted in All Tenders
  • Quick Online Quote

Tender Documents

  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
lock-red

Unlock the Tender details for free

description-svgrepo

Bidder Details

Bidder NameTechnical BidFinancial BidAOCBid ValueRank
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in