District Panchayat
- AOC value
- Refer Docs
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Authority
- District Panchayat
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
District Panchayat has published Procurement Of Fully Automatic Biochemistry Analyser , Govt District Homeo Hospital Ultra Sound Scanning Machine With Doppler Facility , Specifications For Fully Automatic Biochemistry Analyser 1) Automated, Discrete, Bench Top Random Access Clinical Chemistry Analyzer Capable Of Performing Biochemistry And Immunoturbidimetry Assays And It Should Be Upgradable To Ise. 2) The Throughput Should Be At Least 200 Tests/Hr Photometric Tests And 400 Tests/Hr With Ise (Optional) With Na+, K+, Cl-. 3) Sample Disk Should Accept Minimum 35 Samples At A Time. All The Positions On The Sample Disk Should Accept Stat Samples, Blanks, Controls, Standards And Ise Solutions. Auto Dilution Of Samples And Calibrators. It Should Accept 5 Ml, 7 Ml, 10 Ml And Sample Cups For Keeping Samples.The Sample Pipetting Should Be Between 2 – 65 ?L . 4) The Reagent Tray Should Be Cooled And Should Accept More Than 45 Reagent Bottles. It Should Accept Both 20 Ml, 50 Ml Bottles And 5 Ml Adopters. Option To Use One Reagent For Several Tests Simultaneously. Reagent Pipetting Should Be Between 50 – 300 ?L In Steps Of 1?L. 50 Positions For Reagents With On Board Cooling. It Should Have More Than 45 On Line Chemistries. It Should Have Barcode Reader For Both Reagents And Samples (Optional). 5) The Reaction Cuvettes Should Be More Than 40 And Made Up Of Permanent Hard Glass Cuvettes. Possibility Of Replacement Of Individual Cuvettes. Automatic Cuvette Blank Measurement Before Analysis. Assay Methods End Point, Kinetic, Ise. The Minimum Reading Volume Should Be 180 ?L Or Less. Photometer Should Consist Of 8 Stationary Filters. 340, 405, 505, 546, 578, 600, 660 And 700 Nm. It Should Be Capable Of Doing Monochromatic And Biochromatic Measurements. Absorbance Range Should Be 0.0 – 2.5 Abs. Reagent Compartment With Peltier Or Air Cooler 8- 12 Degree Celsius. Reusable Reaction Cuvettes Should Be Available. The Mixing Stirrer Should Have User Defined Variable Speed (Minimum 3 Speeds).Dispensing Probe Equipped With Liquid Level Sensor And Crash Detector. Water Consumption Should Be < 7 Litres. Colour Indication Of Sample Analysis, Possibility Of Monitoring The Reaction In Real Time, Reagent Volume Monitoring. System Should Be Capable Of Performing 2 Reagent Chemistries. 6) Display Of Reaction Cuvette Temperature And Reagent Tray Temperature Should Be Available On Screen.Display Of Tank Pressure Should Be Available. Light Source Should Be Halogen Lamp. On Line Reaction Graph Should Be Displayed On The Screen And All The Reaction Graphs Should Be Stored In The Memory. 7) Biohazard Waste Should Be Collected In A Separate Container. It Should Have On Board Laundry For Washing Of The Cuvettes. 8) It Should Have Extensive Q. C. Program. 4 Levels Of Control Material Can Be Used. Should Show Daily And Monthly Levy Jennings Chart And Twin Plot. It Should Accept Linear, Non-Linear, Multi Point Calibration. 9) Convenient User Interface, Connection To Lis, Statistical Methods Of Processing Results, Data Export In Selected Format. It Should Not Have Any Limit On Number Of Programmable Chemistries, Profiles And Calculation Item. 10) Pc Requirements- Operating System: Ms Windows Xp Or Ms Windows 7, Pentium 4, Ram 2 Gb, Hdd 200 Gb 11) Power Backup- 5 Hours. Last date of submission for this tender is 2024-12-19. This is a Chemistry Analyzers tender in Kollam, Kerala
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
3 issued- Tender Document 1htmlHTML document
- Tender Document 2xlsxXLSX document
- Tender Document 3pdfPDF document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free