🎉 Your free trial plan has started. Plan will expire in 0 days

Central Reserve Police Force

kannur, kerala

AOC value
₹27.3L
AOC date
11 Dec
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 11 Dec 25AOC date

Important info

Result ID
Refer Docs
Award of contract
11/12/2025
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Central Reserve Police Force has published Tender For Repair/ Replacement Of Vertical Sewer Pipe Lines Of 2 Nos. 405 Men Barracks (Namely Bhagat Singh And Chandra Sekhar Azad); 1 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 100 mm dia pipe 2 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 75 to 80 mm dia pipe 3 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm 4 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 5 Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer- in-charge. 6 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. 7 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 8 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 9 Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm 10 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 12 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White 13 Surface Preparation: At the mother slab, the surface must be grinded to remove any unwanted materials like waste, sludge or algae. Pressure washing to be done to ensure clear surface for application is attained. Coving at the corners and junctions to be done by means of Asian Paints SmartCare Repair mortar or polymer modified mortar. Water ponding to be done to ensure no leakages are found, if found must be cleared by means of SmartCare PU Injection, plumbing junctions must be packed to avoid any gaps between the pipe and concrete junctions by means of SmartCare GP Grout which must be done by professional labours.Waterproofing: Providing and application of Asian Paints SmartCare ULTRABLOCK 2K, which is a twocomponent acrylic polymer modified high performance coating system having good excellent waterproofing and excellent resistance to hydrostatic pressure by forming a seamless elastic coating which can resist up to 5 bar positive hydrostatic pressure. It has an elongation >220%, tensile strength of 1.72MPa, Adhesion strength of 1.64 MPa and Vapour permanence 0.32 Perms. The coating must be done with a coverage of 0.6 Sq.m/kg. Application: SmartCare Ultrablock 2K must be done over a SSD masonary brick wall with brush or roller. Allow the first coat to dry for 4-6 hrs, the second coat must be done in perpendicular to the direction of first coat and allowed to cure, application must be done to achieve a minimum coverage of 1.2 Sqm/kg/coat, curing of the waterproofing compound to be done for minimum of 3-5 days depending on the surface condition. 14 Providing and fixing UPVC trap of self cleansing designwith or without vent arm complete, including cost of cutting and making good the walls and floors complete as per the direction of Engineer in charge. 100 mm inlet and 100 mm outlet 15 Providing and fixing UPVC trap of self cleansing designwith or without vent arm complete, including cost of cutting and making good the walls and floors complete as per the direction of Engineer in charge. 100 mm inlet and 75 mm outlet 16 Providing and laying UPVC SWR type B pipes conforming to IS 13592 for soil waste and vent pipes including necessary connections etc complete as per the direction of Engineer in charge. 110 mm diameter 17 Providing and laying UPVC SWR type B pipes conforming to IS 13592 for soil waste and vent pipes including necessary connections etc complete as per the direction of Engineer in charge. 75 mm diameter 18 Providing and fixing UPVC single equal plain junction of required degreewith access door to UPVC SWR pipes, including necessary connections etc complete as per the direction of Engineer in charge. 110x110x110 mm 19 Providing and fixing UPVC bend of required degreeto UPVC SWR pipes, etc complete.as per the direction of Engineer in charge. 110 mm 20 Providing and fixing UPVC terminal guard to UPVC type Bsoil waste and vent pipes including necessary connections etc complete as per the direction of Engineer in charge. 110 mm 21 Providing and fixing UPVC terminal guard to UPVC type Bsoil waste and vent pipes including necessary connections etc complete as per the direction of Engineer in charge. 75 mm 22 Providing and fixing UPVC single equal plain junction with access door to UPVC type Bsoil waste and vent pipes including necessary connections etc complete as per the direction of Engineer in charge. 75 mm 23 Providing and fixing UPVC bend to UPVC type Bsoil waste and vent pipes including necessary connections etc complete as per the direction of Engineer in charge. 75mm 24 Providing and fixing CP brass health faucet with 8mm dia 1.2mtr long flexible connecting tube and wall hook 25 Providing and fixing C.P. brass 2 in 1 tap ofapproved quality conforming to IS standards as directed by engineer-in-charge . Last date of submission for this tender is 2025-11-14. This is a Pipe Laying tender in Kannur, Kerala

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

6 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in