🎉 Your free trial plan has started. Plan will expire in 0 days

Indian Institute Of Technology

dharwad, karnataka

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Indian Institute Of Technology has published Tender For Supply, Installation And Commissioning Of Battery Pack Testing Equipment At Indian Institute Of Technology Dharwad; 1. Battery pack capacity requirement a. Voltage: 0 to 100 V b. Current: 0 to 1200Ah c. Number of Channels: 2 d. Control Mode: Independent control (Pulse and SIM tests disabled when in parallel mode). e. Channel Feature: Dual closed-loop control for constant current and constant voltage operation. 2. Power supply requirements parameters: a. Input Power Supply: AC 380V ±15%, 50/60Hz ±5% b. Power Factor: ≥99% (Full Load) c. THDi: ≤5% (Full Load) d. Input Impedance: ≥1 MΩ e. Input Power: 280-300 kW; Input Current: 429 A/single f. Overall System Efficiency (Max): 90- 95% g. Noise Level: ≤65 dB h. Power Control Module Type: MOSFET i. Input Power Wiring: Three-phase, five-wire system j. Power Input Protection: Anti-surge, anti-islanding, over/under-frequency, over/under-voltage, and open-phase protection. k. Input power supply cable length to battery pack tester unit: Minimum 3 meters. l. Connector cable length from battery pack tester unit to cell clamp holder unit: Minimum 5 meters. 3. Functional and Performance Specifications a. Voltage Output Range: Charge 0–100V; Discharge 3–100V (Min. Discharge Voltage: 3V), Accuracy: ±0.02% of FS; Resolution: 24-bit. b. Current Output Range: 60A / 120A / 240A / 1200A (Selectable Range), Current Accuracy: ±0.05% of FS; CV Cut-off Current: 100 mA; Resolution: 24-bit c. Single Channel Output Power: 120 kW; Total System Output Power: 240 kW d. Current response Time: ≤3 ms; Conversion Time: ≤6 ms; Minimum Step Time: 0.1 s e. Charge/Discharge Modes: CCC, CVC, CC-CVC, CPC, CCD, CVD, CC-CVD, CPD, CRD. Cut-off Conditions: Voltage, Current, ΔTime, Capacity, -ΔV f. Simulation: Charging/Discharge with current and power mode,switching with programmable timestep control g. Pulse Step Mode: Charging/Discharge with current and power, Minimum Pulse Duration 50 ms, up to 32 Pulse Counts, Voltage/ΔTime cut-off control. h. DCIR Measurement: Supported via calculation. i. Safety and Protection Features: 1.Software Protection: Includes voltage, current and time limits, with data protection and offline mode. 2.Hardware Protection: Anti-reverse connection, over-voltage, over-current, and over-temperature. 4. Data Management and Communication a. Step Setting: Configurable via Form Editing b. Recording Interval: Minimum 10 ms (100 ms with AUX) c. Voltage Interval: 200 mV; Current Interval: 100–200 mA depending on range d. Recording Frequency: 100 Hz (10 Hz with AUX Channel) e. Database: MySQL Database; Output Formats: Excel, TXT or CSV. f. Curve Templates: Standard and customizable format. g. Barcode Scanning: Supported for data traceability and management. h. Communication Protocol: TCP/IP over Ethernet (1M bandwidth for lower computer; 10M–100M adaptive for host computer) i. Networking: Local area network via switch/router setup. j. Optional Communication: CAN, RS485 and BMS Communication (DBC Configuration Supported). 5. Environmental and Physical Conditions a. Operating Temperature: -10°C to 40°C (Accuracy drift <0.005% FS/°C within 25±5°C) b. Storage Temperature: -20°C to 50°C c. Operating Humidity: ≤70% RH (No condensation) d. Storage Humidity: ≤80% RH (No condensation) 6. Additional requirement along with the Battery pack tester 1. 100 Quantity of 46800 NMC cells, Nominal voltage: 3.7 V, Capacity: 22 Ah 2. 100 Quantity of 18650 NMC cells, Nominal voltage: 3.6 V, Capacity: 3 Ah 3. 100 Quantity of 21700 NMC cells, Nominal voltage: 3.6 V, Capacity: 4.9 Ah 4. Lithium Battery pack spot welding machine of capacity of 4KVA. . Last date of submission for this tender is 2026-01-27. This is a Testing Machine tender in Dharwad, Karnataka

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

2 issued
  • Tender Document 1pdf
  • Tender Document 2html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in