Bangalore Bioinnovation Centre has published Tender For Fire Safety System Work - Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes Confirming To Is-1239 Part - I With Butt Welded Specials Confirming To Is-1239 Part - Ii, Such As Tees, Elbows, Check Nuts, Unions, Flanges, Nipplesetc. Including Cutting, Welding, Fixing In / On Walls - 80Mm Dia,Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes Confirming To Is-1239 Part - I With Butt Welded Specials Confirming To Is-1239 Part - Ii, Such As Tees, Elbows, Check Nuts, Unions, Flanges, Nipplesetc. Including Cutting, Welding, Fixing In / On Walls - 65Mm Dia,Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes Confirming To Is-1239 Part - I With Butt Welded Specials Confirming To Is-1239 Part - Ii, Such As Tees, Elbows, Check Nuts, Unions, Flanges, Nipplesetc. Including Cutting, Welding, Fixing In / On Walls - 50Mm Dia,Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes Confirming To Is-1239 Part - I With Butt Welded Specials Confirming To Is-1239 Part - Ii, Such As Tees, Elbows, Check Nuts, Unions, Flanges, Nipplesetc. Including Cutting, Welding, Fixing In / On Walls - 40Mm Dia,Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes Confirming To Is-1239 Part - I With Butt Welded Specials Confirming To Is-1239 Part - Ii, Such As Tees, Elbows, Check Nuts, Unions, Flanges, Nipplesetc. Including Cutting, Welding, Fixing In / On Walls - 32Mm Dia,Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes Confirming To Is-1239 Part - I With Butt Welded Specials Confirming To Is-1239 Part - Ii, Such As Tees, Elbows, Check Nuts, Unions, Flanges, Nipplesetc. Including Cutting, Welding, Fixing In / On Walls - 25Mm Dia,Supplying, Installing, Testing And Commissioning Ci Motorised Butterfly Valves ( Pn 16) Slim Seal Standared Lever Operated Type Confirming To Bs - 5155 With Required Flanges,Nuts, Bolts Etc. Complete. 80Mm Dia,Supplying, Installing, Testing And Commissioning Ci Motorised Butterfly Valves ( Pn 16) Slim Seal Standared Lever Operated Type Confirming To Bs - 5155 With Required Flanges,Nuts, Bolts Etc. Complete. 50Mm Dia,Supplying, Installing, Testing And Commissioning Ci Motorised Butterfly Valves ( Pn 16) Slim Seal Standared Lever Operated Type Confirming To Bs - 5155 With Required Flanges,Nuts, Bolts Etc. Complete. 40Mm Dia,Foam Water Sprinkler,Mechanical Foam Tank 2000 Ltr (Civil Work Clint Scope),Supply Of Mechanical Foam,Supply And Installation Of Optical (Photo Electric) Smoke Detector With Base, Junction Box And Other Accessories As Required,Supply And Installation Of Addressable Type Hooter With Base,Supply And Installation Of Manual Call Point (Break Glass Type) With Back Box,Supply And Installation Of Relay Module,Supply And Installation Of 2 Core X 1.5 Mm2, Unarmoured, Frls Outer Sheathed Pvc Insulated Copper Conductor Cable To Connect All Fire Alarm Devices Into Facp,System Programming Testing And Commissioning Charge (1St Floor),Supply And Installation Of 2 Core X 1.5 Mm2, Unarmoured, Frls Outer Sheathed Pvc Insulated Copper Conductor Cable To Connect All Fire Alarm Devices Into Facp (Pa Systems),Supply And Installation Of 6W Celing Mounding Speaker (Pa Systems),Supply And Installation Of Booster Amplifier Including Necessory Control Wires, Jacks Etc. Complete.,Installation Of Smoke Detector (External),Supply And Installation Of Addressable Type Hooter With Base (External),Installation Of Old Hooter (External),Supply And Installation Of Manual Call Point (Break Glass Type) With Back Box (External),Installation Of Old Mcp (External),Supply And Installation Of 2 Core X 1.5 Mm2, Unarmoured, Frls Outer Sheathed Pvc Insulated Copper Conductor Cable To Connect All Fire Alarm Devices Into Facp (External),System Programming Testing And Commissioning Charge (External),Supplying And Laying Of Pvc Conduit Long With Accessories In Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. Size - 20 Mm (External),Ms Cylinder 4 Kg Dlp Assembly With Automatic Valve 4 Kg Ms Cylinder, Dlp Assembly With Automatic Valve,Fk-5-1- 12 Ul Listed Clean Agent, Mounting Bracket, Spring Top Connector , Pressure Switch , End Of Line Adaptor.,Heat Sensing Tube Red Hr Grade Heat Sensing Tube Red Hr Grade, Single Layer Special Modified Polyamide Material, Tube Id 4Mm Od 6Mm, Operating Pressure 15-18 Bar, Maximum Pressure 30 Bar At Maximum Temperature Of +65 Degree C, Burst Temperature 125 Degree C, Service Life 3-4 Years, Long Term Application, Max Bend In Installation 140Mm, Max Space Between Tubes 250Mm,Master Control Unit For Monitoring The Health Of The System,Fire Status Dual Red Led,Having Dual Tone Buzzer To Indicate Fire Status, Construction Of Panel-(20 Swg) C.R Sheet,Finishing Red,Cable Entry Bottom Top Entry 19 Mm Knock Out, Dimension (105X190x80)Mm,Current Consumption 25 Watts,Type Of Tone Dual Tone,90-100 Db At 1 Meter Distance,Output 1 Set Of Potential Free No Nc Com Only, Contact Rating 1A/120V Ac & 2A/24V Dc,Indication Green Led (On) Red Dual Tone Flashing Type,Supplying, Installing, Testing And Commissioning Of Heavy Grade Gi. Pipes 100Mm Dia (Ground Floor),Supplying, Installing, Testing And Commissioning Ci Motorized Butterfly Valves 100Mm Dia (Ground Floor),Supplying, Installing, Testing And Commissioning Ci Motorized Butterfly Valves 40Mm Dia (Ground Floor),Supplying, Installing, Testing And Commissioning Ci Motorized Butterfly Valves 50Mm Dia (Ground Floor),Existing Pipe And Valves Dismandling And Refabrication Work (Ground Floor),Supply And Installation Of Optical (Photo Electric) Smoke Detector With Base, Junction Box And Other Accessories As Required (Ground Floor),Supply And Installation Of Addressable Type Hooter With Base (Ground Floor),Supply And Installation Of Manual Call Point (Break Glass Type) With Back Box (Ground Floor),Supply And Installation Of 2 Core X 1.5 Mm2, Unarmoured, Frls Outer Sheathed Pvc Insulated Copper Conductor Cable To Connect All Fire Alarm Devices Into Facp (Ground Floor),System Programming Testing And Commissioning Charge (Ground Floor),Supply And Installation Of Relay Module (Ground Floor),Supply Of Addressable 4 Loop Panel (Ground Floor),Supplying And Laying Of Pvc Conduit Long With Accessories In Recess Includin Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. Size - 20 Mm (Ground Floor),Supply And Installation Testing And Commissioning Of Pressure Gauge. Last date of submission for this tender is 2025-06-29. This is a Fire Fighting Service tender in Bangalore, Karnataka

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in