🎉 Your free trial plan has started. Plan will expire in 0 days

South Eastern Railways

ranchi, jharkhand

AOC value
₹12.68L
AOC date
20 Apr
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 20 Apr 26AOC date

Important info

Result ID
Refer Docs
Award of contract
20/04/2026
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

South Eastern Railways has published Supply Of Supply Of Outdoor Type , Plinth Mounted, Distribution Transformer, Minimum Energy Efficiency Level 3 Of Rating 250 Kva, 3-Phase, 11Kv/415-240V,50Hz, Oil Immersed, Non Sealed Type (Transformer Tank Body And Cover Are Bolted), Copper Wound, Primary Winding In Delta And Secondary Winding In Star (Vector Symbol- Dyn11), Onan Cooled Transformer, Conforming To Is 1180 (Part1):2014 With Amendment Nos. 1,2,3,4 Or Latest, And Supplied With All Standard Fittings Mentioned In Clause 20.1 Of Is 1180 (Part 1) Latest With Condition That Drain-Cum-Sampling Valve. Oil Temperature Indicator & Winding Temperature Indicators Will Be Provided As Per Clause 20.2 F) Of Is 1180 (Part 1). Terminal Arrangement: The Transformers Shall Be Fitted On High Voltage And Low Voltage Sides Bushing Appropriate Voltage And Current Ratings., Low Voltage Side Cable End Box Required . The High Voltage Bushings (3 Nos.) Shall Conform To Is/ Iec 60137. The Low Voltage Bushings (4 Nos.) Shall Conform To Is 7421. Off-Circuit Tap Changer (Applicable For All Ratings Above 200 Kva) For Variation Of Hv Voltage From +5% To -10% In Steps Of 2.5%. Following Has To Be Submitted By Supplier Along With Supply Of Material: (I) Type Test Report Of Transformer Having Same Rating, Make (& Model If Any) And Design From Nabl Accredited Lab As Per Is: 1180 (Part 1) Latest. (Ii) Routine Test Certificates As Per Is: 1180 (Part 1) Latest. (Iii) Special Test Certificates As Per Clause 21.4 Sl. No. (A), (C), (D) & (E) Of Is:1180 (Part 1) Latest.Supply Of Outdoor Type , Plinth Mounted, Distribution Transformer, Minimum Energy Efficiency Level 3 Of Rating 250 Kva, 3-Phase, 11Kv/415-240V,50Hz, Oil Immersed, Non Sealed Type (Transformer Tank Body And Cover Are Bolted), Copper Wound, Primary Winding In Delta And Secondary Winding In Star (Vector Symbol- Dyn11), Onan Cooled Transformer, Conforming To Is 1180 (Part1):2014 With Amendment Nos. 1,2,3,4 Or Latest, And Supplied With All Standard Fittings Mentioned In Clause 20.1 Of Is 1180 (Part 1) Latest With Condition That Drain-Cum-Sampling Valve. Oil Temperature Indicator & Winding Temperature Indicators Will Be Provided As Per Clause 20.2 F) Of Is 1180 (Part 1). Terminal Arrangement: The Transformers Shall Be Fitted On High Voltage And Low Voltage Sides Bushing Appropriate Voltage And Current Ratings., Low Voltage Side Cable End Box Required . The High Voltage Bushings (3 Nos.) Shall Conform To Is/ Iec 60137. The Low Voltage Bushings (4 Nos.) Shall Conform To Is 7421. Off-Circuit Tap Changer (Applicable For All Ratings Above 200 Kva) For Variation Of Hv Voltage From +5% To -10% In Steps Of 2.5%. Following Has To Be Submitted By Supplier Along With Supply Of Material: (I) Type Test Report Of Transformer Having Same Rating, Make (& Model If Any) And Design From Nabl Accredited Lab As Per Is: 1180 (Part 1) Latest. (Ii) Routine Test Certificates As Per Is: 1180 (Part 1) Latest. (Iii) Special Test Certificates As Per Clause 21.4 Sl. No. (A), (C), (D) & (E) Of Is:1180 (Part 1) Latest.,Supply Of Outdoor Type , Plinth Mounted, Distribution Transformer, Minimum Energy Efficienc Y Level 3 Of Rating 250 Kva, 3-Phase,11Kv/415-240V,50Hz, Oil Immersed, Non Sealed Type (Transformer Ta Nk Body And Cover Are Bolted), Copper Wound, Primary Winding In Delta And Secondary Winding In Star (Ve Ctor Symbol- Dyn11), Onan Cooled Transformer, Conforming To Is 1180 (Part1):2014 With Amendment Nos. 1,2,3,4 Or Latest, And Supplied With All Standard Fittings Mentioned In Clause 20.1 Of Is 1180 (Part 1) Latest With Condition That Drain-Cum-Sampling Valve. Oil Temperature Indicator & Winding Temperature Indicators Will Be Provided As Per Clause 20.2 F) Of Is 1180 (Part 1).Terminal Arrangement: The Transformers Shall Be F Itted On High Voltage And Low Voltage Sides Bushing Appropriate Voltage And Current Ratings., Low Voltage Si De Cable End Box Required. The High Voltage Bushings (3 Nos.) Shall Conform To Is/ Iec 60137. The Low Volta Ge Bushings (4 Nos.) Shall Conform To Is 7421. Off-Circuit Tap Changer (Applicable For All Ratings Above 200 Kva) For Variation Of Hv Voltage From +5% To -10% In Steps Of 2.5%. Following Has To Be Submitted By Suppl Ier Along With Supply Of Material: (I) Type Test Report Of Transformer Having Same Rating, Make (& Model If Any) And Design From Nabl Accredited Lab As Per Is: 1180 (Part 1) Latest. (Ii) Routine Test Certificates As Pe R Is: 1180 (Part 1) Latest. (Iii) Special Test Certificates As Per Clause 21.4 Sl. No. (A), (C), (D) & (E) Of Is:1180 (Part 1) Latest. [ Warranty Period: 30 Months After The Date Of Delivery ] ]. Last date of submission for this tender is 2025-11-13. This is a Distribution Transformer tender in Ranchi, Jharkhand

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in