🎉 Your free trial plan has started. Plan will expire in 0 days

Shri Mata Vaishno Devi University

Laboratory Equipment And Supplies
reasi, jammu and kashmir
AOC Value₹13.99 Lac
AOC Date19 Feb 2026
Completion DaysRefer Docs
Bid AmountRefer Docs

Important Info

Result ID
Refer Docs
Award of Contract
19/02/2026
Authority
Shri Mata Vaishno Devi University
Published Date
Refer Docs
Tender Closing Date
Refer Docs
Tender No
55(00)/2025-2026/XXX/5XX
Bidding URL
https://www.exampletenders.gov.in/bid/98765
Tender
View Tender
Bidder Details
Bidder Name: Mr. Jhon Doe, Ranking 2

AOC Description

Shri Mata Vaishno Devi University has published Tender For Supply, Installation, Demonstration And Commissioning Of Purchase Of Various Lab Equipment For Transportation Engineering Lab At School Of Civil Engineering, Smvdu Kakryal, Katra , Cannon Manning Cum Cannon Fenske Viscometer (For Determination Of The Absolute Viscosity & Kinematic Viscosity Of Bitumen & Cut - Backs) As Per Is: 1206 (Part Ii) - 1978, Reaffirmed 2003, For Determination Of Absolute And Kinematic Viscosity Of Bitumen And Cut-Backs As Per Is Standards Cannon-Manning Vacuum Viscometer (02) Has The Following Specifications: Absolute Viscosity Of Bitumen At 60 °C, Operates Under Vacuum Of 30 ± 0.05 Cm Hg, Viscosity Measuring Range: 30 To 20,000 Poise. Made Of High-Precision Borosilicate Glass (Astm E438 Type I, Class A); Supplied With Individual Calibration Constant. Cannon-Fenske Opaque Viscometer (02) For Kinematic Viscosity Of Bitumen/Cut-Backs At 135 °C;Operates Under Gravity Flow; Viscosity Range: 0.5 To 10,000 Cst; Borosilicate Glass, Annealed For Stress Relief; Supplied With Individual Calibration Constant; Temperature Control Bath: Advanced Digital Constant Temperature Bath With Microprocessor-Based Pid Controller; Temperature Range:Ambient +5 °C To 150 °C, Accuracy: ±0.05 °C, Uniformity: ±0.1 °C Across Bath, Bath Capacity: Minimum 15 Litres, Stainless Steel Inner Chamber;Stirring: Magnetic / Circulating Pump For Uniform Temperature Distribution, Digital Display: Dual Led/Lcd Display For Set And Actual Temperature. Vacuum System (For Cannon-Manning): Precision Vacuum Pump With Fine Control Valve, Vacuum Regulation: 30 Cm Hg ±0.05 Cm Hg, Digital Vacuum Gauge For Real-Time Monitoring, Silent, Oil-Free Operation With Moisture Trap, Digital Stopwatch/Timer (Least Count: 0.1 Sec), Is/Astm Standard Thermometers / Digital Pt-100 Probe (Range 0-150 °C, Accuracy ±0.1 °C); Standard Reference Oils (For Calibration Check, Nabl Traceable); Protective Viscometer Holder Assembly With Levelling System; Safety Cover Over Bath With Insulated Lid. Suitable For 220-240 V Ac, 50 Hz, Single Phase. , Flash Point (Open) And Fire Point Cleveland (For Determining The Flash And Fire Points Of Petroleum Products, Except For Fuel Oil And Those Products Which Have Open Cup Flash Point Below 79° C (175° F). Standards - Is:1209-1978, Is:1448 (69)-2019, Cleveland (Open Cup)) Electrical Heating With Electric Heater. This Apparatus Consists Of The Test Cup, Heating Plate, Test Flame Applicator, Heater, Supports As Described In Is 1209-1978 Specifications And Accessories For Converting Open Cup Model To Close Cup Model, Preferred. The Complete Apparatus Is Manufactured From Brass Or Stainless Steel Material, Heater Is Controlled By Energy Regulator And A Gas Test Jet Assembly And Temperature Displayed On Digital Temperature Indicator Fitted To The Apparatus. Suitable For Operation On 220 Volts, 50 Hz, Ac Supply. , Flash Point Pensky-Martens Apparatus (For Determining The Flash Point Of Fuel Oils And Lubricating Oil, Bitumen Other Than Cutback Bitumen And Suspension Of Solids In Liquids, Having A Flash Point Above 49°C.) Standards - Is:1209-1978, Is:1448 (69)-2019, Pensky-Martens (Closed Cup)) Electrical Heating With Electric Heater. Assembly Consists Of Brass Test Cup With Handles, Constant Speed Motorized Stirrer, Accessories For Converting Close Cup Model To Open Cup Model Preferred.. The Temperature Range From 40 To 360° C By A Manual Pensky Martens Closed Cup Apparatus. Fitted With Electronic Digital Temperature Indicator And Energy Regulator Control And A Gas Test Jet Assembly. Suitable For Operation On 220V, 50Hz, Single Phase, Ac Supply. , Bulk Density Measurement Set (3/15/30 Lt) As Per Is : 2386 (Part - Iii) -1963, Is : 10079-1982, Cylindrical Measure With Tamping Rod Required For Determining The Bulk Density Or Unit Weight Of Aggregates. Three Calibrated Cylindrical Measures One Each Of 3 Litre, 15 Litre And 30 Litre Capacity Made Out Of Thick Gauge Steel Sheet With Handles Stout And Rigid To Retain Form, Complete With One Tamping Rod 16 Mm Dia X 60 Cm Long Rounded At One End. , Ring And Ball Apparatus As Per Is 1205:2022 Applies To Bitumen, Tar, Coal Tar Pitch, And Related Materials Softening Point. Ring Dimensions: Two Tapered Rings In Brass, Balls: Steel Balls 9.5 Mm In Diameter, Weighing 3.50 ± 0.05 G Each, Two Ball Centring Guides, A Ring Holder And A Bath 8.5 Cm Dia X 12 Cm Deep Approx. Features A Magnetic Stirrer, Heating Facility, And A Digital Temperature Display. Glass Beaker With Cover, Ring & Ball Stand, Cork For Thermometer, Brass Base Plate For Preparing The Specimen. Temperature Control Is Via An Integrated Pid Controller And Operate On 220 V, 50 Hz, Single-Phase Ac Supply. , Benkelman Beam With Digital Dial Gauge As Per Irc:81-1997, Guidelines For Pavement Strengthening Using Benkelman Beam, Length 3.66 M; Pivot 2.44 M From Tip, Rebound Deflection (Used For Overlay Design), Use Known-Thickness Blocks; ½ Thickness Equals Gauge Reading, =10 Points Per Section; =50 M Spacing, 0.01 Mm/°C; Standard = 35 °C, Apply Correction Based On Climate/Moisture Seasonal Effects, Available Automated Variants And Specs In Morth Documents, Supplied With A Digital Dial Gauge Of 0.001 X 12.5Mm Or 12.7Mm Or 25Mm. , Refrigerated Ductility Tester Temperature Controlled As Per Is 1208 (Part 1): 2023 - Methods For Testing Tar And Bituminous Materials - Part 1: Determination Of Ductility, Apparatus Specifications -The Test Apparatus Comprises A Brass Briquette Mould (With Precise Dimensions), A Water Bath Maintained Within ± 0.1 °C Of The Test Temperature, A Testing Machine For Horizontal Pull, And A Thermometer With Defined Accuracy And Range. Test Conditions - Standard Temperature: 25.0 ± 0.5 °C, Pull Rate: 50.0 ± 2.5 Mm/Min, For Low-Temperature Testing: 4.0 ± 0.5 °C.The Rotating Shaft Has 2 Speeds Of Travel For The Bracket, 5 Cm/Min And 1Cm/Min, Selected By A Clutch. Features Digital Touch-Screen Control, Preferred, Variable Pull Rates, And Refrigeration, The Temp. Is Controlled By Dual Display Microprocessor Based Auto Tuning Pid Digital Temp. Indicator Cum Controller, Complete With Three Briquette Moulds, Working On 220/230 Volts Ac, Single Phase. , Automatic Marshall Stability Test Machine (Digital) As Per Indian Standard: Is 17127:2019 , Defines The Method For Stability (Maximum Load), Flow (Deformation Under Load), And Bulk Density When Loaded On The Lateral Surface Using A Marshall Apparatus. Specification: Capacity Of The Load Frame - 100Kn, Platen Diameter - 150Mm, Platen Speed - 0.001- 51 Mm/Min, Breaking Head Assembly With Flow Meter For 150 Mm, Rammer For Marshal 10.2 Kg (2 Nos.), Modified Marshal Mould 150Mm Dia Complete (3Nos.), Pedestal For Holding The Mould 150 Mm(1Nos), Rammer 5.2 Kg - 2 Nos, Load Cell - 100Kn, Displacement Sensor Along With Flow Meter - +20Mm, Accessories For 100 Mm Dia. Specimen, 100 Mm Dia. Mould - 3 Nos., Pedestal For Holding The Mould 100 Mm (1 Nos), Rammer 5.2 Kg - 2 Nos., Breaking Head Assembly - 1 No. Touchscreen Interfaces With High-Resolution Tft-Lcd, Real-Time Load Vs. Time/Displacement Graphs. Internal Storage, Usb, Ethernet, Pc Software Support For Data Export, Suitable For Operation On 220V, 50 Hz, Single Phase, Ac Supply. , Thermo Statically Controlled Oven (300 -350 Lt.) As Per Is/Astm Standards And Aicte Norms, Thermostatically Controlled Oven Used For Heating, Drying, And Conditioning Of Aggregates, Bitumen, And Bituminous Mixes At Controlled Temperatures During Various Tests In Transportation/Bitumen Labs The Standard Specifications Are Doublewalled Construction With Outer Body Made Of Mild Steel (Powder Coated), Inner Chamber Made Of Stainless Steel / Mild Steel With Heat-Resistant Enamel, High-Grade Mineral/Glass Wool To Minimize Heat Loss, Ambient +10°C To 250°C, Thermostatic Or Digital Pid Controller With Accuracy Of ±1°C, Temperature Uniformity Maintained By Forced Air Circulation, High-Quality Heating Element Chrome Wire / Tubular Heaters, Ensures Uniform Heating Across Chamber, Adjustable Shelves(Min. 03) Made Of Stainless Steel Perforated Sheet With Removable For Flexibility, Capacity Volume: 300 To 350 Litres, 220/230 V, Single-Phase, 50 Hz Ac.Compliance With Is: 6365-1971: The Equipment Should Confirm To This Indian Standard, Which Covers Safety Requirements, Tests, And Marking For Laboratory Ovens. Door: A Sealed Main Door With A Silicone Gasket & Lock. Safety Features Such As Overtemperature Protection, An Automatic Over-Temperature Alarm, And Thermal Cut-Off. Casters For Easy Movement.. Last date of submission for this tender is 2026-01-21. This is a Laboratory Equipment tender in Reasi, Jammu And Kashmir

Insurance Surety Bond

Fast, Reliable & Accepted for EMD/PBG

  • Zero BG Limit Impact
  • Accepted in All Tenders
  • Quick Online Quote

Tender Documents

  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
  • Tender Document 7pdf
lock-red

Unlock the Tender details for free

description-svgrepo

Bidder Details

Bidder NameTechnical BidFinancial BidAOCBid ValueRank
Sharma infra projects pvt ltd
₹1,24,50,000.00L1
Verma constructions ltd
₹1,31,00,000.00L2
Nair engineering works
₹1,38,75,000.00L3
Iyer industrial solutions
₹1,43,20,000.00L4
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in