Sher- I -kashmir Institute Of Medical Science
- AOC value
- ₹15.87L
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Sher- I -kashmir Institute Of Medical Science has published Bids Are Invited For Rt Pcr ( Q3 ) • The System Should Be Controlled By Touch Screen And External Computer Also. The Software Should Come With A Broad Spectrum Of Optimized Analysis Algorithms Including Absolute And Relative Quantification, Ducts Method, Pcr Efficiency, Allelic Discrimination, Endpoint Detection As Well As Melt Point And Protein Analysis. • System Should Have Thermal Silver Block With Gold Plating 96 X 0.2 Ml Well Format With Gradient Function, Performs Both Real Time And End Point Analysis With Sample Size Volume Capacity 5 –100 Μl. • The System Should Have An Array Of 8 High Performance Optical Fibres In A Shuttle System To Direct Led Light Bundled By Lenses To Samples For Lossfree Excitation Scanning For Best Uniformity And Reproducibility. • Depending On The Application System Filter Module System Should Be Freely Configured And Upgradable To Both Intercalating And Proteinbinding Dyes, With 12 Different Available Colors As Well As To Hybridization ( Fret ) Probes. The System Should Be Future-Proof, Being Easily Retrofitted On-Site With Additional Color, Fret Or Protein Modules, And Can Thus Be Adapted To Other Fields Of Application At Any Time • The System Should Have An Automatic Software-Controlled Temperature Ramp Rate 8.0°C / Second For Heating And 6°C / Second For Cooling With A Temperature Range: 3-99°C & Hot Top Heated Lid. • The Excitation Source Should Be Long Live 4Robust Leds No Preheating Time With Longer Life& Detection Should Be From High Sensitive Pmt ( Photo Multiplier Tube ) • The Temperature Control Accuracy Should Be ± 0.1 °C Or Better For Best Performance & Temperature Uniformity Of ± 0.15 °C @ 55 °C After 15 Sec • The System Should Be An Open Platform Supporting All Fluorescent Chemistries And Numerous Applications & Should Be Open For Reagents Of Any Make. • The System Should Come With At Least 6 Color-Filters & Must Be Flexible For Multiplexing Capability And Support Up To True 6 Colors Multiplexing Without Any Rox Dye Needed. • To Avoid Condensation And The Resulting Loss Of Samples, The System Should Be Equipped With A Motorized Heated Lid With A Temperature Range Up To 110 °C And Guarantees, Regardless Of The Consumables Used An Optimal Contact Pressure On The Sample Vessels During The Entire Realtime Pcr Run. • The System Should Have Allelic Discrimination By Threshold Cycle Or By Endpoint Fluorescence Values With Auto-Call Feature. • The System Should Come With 2 Warranty On Device System&10 Years Long-Term Warranty Of High-Performance Optics. • System Should Be Supplied With Computer System To Analyze Data By Software. Total Quantity : 1. Last date of submission for this tender is 2023-08-21. This is a Pcr And Rt Pcr Products tender in Srinagar, Jammu And Kashmir
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
1 issued- Tender Document 1htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free