🎉 Your free trial plan has started. Plan will expire in 0 days

Public Health Engineering Department

poonch, jammu and kashmir

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Public Health Engineering Department has published Item Rate Contract For Improvement / Replacement / Maintenance Of Parts Of Lt Control Panels For The Year 2021-22 In Respect Of Jal Shakti ( Phe ) Division Poonch.- 1 Disconnection Of Incoming Power Connection From Main Switch / Mccb / Voltage Stabilizer And Checking Of Fault 2 Making Of Temporary Arrangement For Running Of Pumping Machinery 3 Replacement Of Damaged Mnx 25 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 25 4 Replacement Of Damaged Mnx 40 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 40 5 Replacement Of Damaged Mnx 50 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 50 6 Replacement Of Damaged Mnx 70 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 70 7 Replacement Of Damaged Mnx 80 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 80 8 Replacement Of Damaged Mnx 95 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 95 9 Replacement Of Damaged Mnx 110 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 110 10 Replacement Of Damaged Mnx 185 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 185 11 Replacement Of Damaged Mnx 225 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 225 12 Replacement Of Damaged Mnx 250 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 250 13 Replacement Of Damaged Kit Of Mnx 25 By Way Of Providing / Fitting Of New Kit 14 Replacement Of Damaged Kit Of Mnx 40 By Way Of Providing / Fitting Of New Kit 15 Replacement Of Damaged Kit Of Mnx 50 By Way Of Providing / Fitting Of New Kit 16 Replacement Of Damaged Kit Of Mnx 70 By Way Of Providing / Fitting Of New Kit 17 Replacement Of Damaged Kit Of Mnx 80 By Way Of Providing / Fitting Of New Kit 18 Replacement Of Damaged Kit Of Mnx 95 By Way Of Providing / Fitting Of New Kit 19 Replacement Of Damaged Kit Of Mnx 110 By Way Of Providing / Fitting Of New Kit 20 Replacement Of Damaged Kit Of Mnx 185 By Way Of Providing / Fitting Of New Kit 21 Replacement Of Damaged Kit Of Mnx 225 By Way Of Providing / Fitting Of New Kit 22 Replacement Of Damaged Kit Of Mnx 250 By Way Of Providing / Fitting Of New Kit 23 Replacement Of Damaged Mpr 24 Replacement Of Damaged Over Load Relay & P / F New Overload Relay 25 Replacement Of Damaged Under Load Relay & P / F New Underload Relay 26 Replacement Of Single Phase Relay & P / Fsingle Phase Relay 27 Replacement Of Reverse Phase Relay & P / Freverse Phase Relay 28 Replacement Of Damaged Mccb 100 By Way Of Providing / Fitting Ofmccb 100 Amp 29 Replacement Of Damaged Mccb 125 By Way Of Providing / Fitting Ofmccb 125 Amp 30 Replacement Of Damaged Mccb 200 By Way Of Providing / Fitting Ofmccb 200 Amp 31 Replacement Of Damaged Mccb 250 By Way Of Providing / Fitting Ofmccb 250 Amp 32 Replacement Of Damaged Mccb 400 By Way Of Providing / Fitting Ofmccb 400 Amp 33 Replacement Of Damaged Mccb 600 By Way Of Providing / Fitting Ofmccb 600 Amp 34 Replacement Of Damaged Mccb 100 By Way Of Providing / Fitting Ofmccb 100 Amp 35 Making Ofincoming Power Connection To Main Switch / Mccb / Voltage Stabilizer And Checking On Full Load. 36 Upto 100 Amp 37 Charges For Minor Repair / Servicing Of Lt Control Panel Including Minor Parts Like Meters, Indicators , Timers Etc 38 Providing / Fitting Ofcircuit Wiring 39 Providing / Fitting Ofvoltmeter 40 Providing / Fitting Of Ampmeter 41 Providing / Fitting Ofamp Selector Switch 42 Providing / Fitting Ofvolt Selector Switch 43 Providing / Fitting Ofpush Button 44 Providing / Fitting Ofindicator Lamps 45 Providing / Fitting Ofstar Delta Timer 46 Providing / Fitting Ofterminal Plate 47 Providing / Fitting Offault Analyzer 48 Providing / Fitting Ofquartz Timer 49 Providing / Fitting Ofdelay Timer 50 Providing / Fitting Ofpower Wiring 51 Providing / Fitting Ofthermal Overload Relay 52 Providing / Fitting Ofbus Bar 53 Providing / Fitting Ofboiled Fuse Link 54 Providing / Fitting Offuse Holder Suitable For Bolted Fuse Link 55 Making Ofincoming Power Connection To Main Switch / Mccb / Voltage Stabilizer And Checking On Full Load. 56 125 Amp. To 200 Amp 57 Charges For Minor Repair / Servicing Of Lt Control Panel Including Minor Parts Like Meters, Indicators , Timers Etc 58 Providing / Fitting Ofcircuit Wiring 59 Providing / Fitting Ofvoltmeter 60 Providing / Fitting Of Ampmeter 61 Providing / Fitting Ofamp Selector Switch 62 Providing / Fitting Ofvolt Selector Switch 63 Providing / Fitting Ofindicator Lamps 64 Providing / Fitting Ofpush Button 65 Providing / Fitting Ofstar Delta Timer 66 Providing / Fitting Ofterminal Plate 67 Providing / Fitting Offault Analyzer 68 Providing / Fitting Of Quartz Timer 69 Providing / Fitting Ofdelay Timer 70 Providing / Fitting Ofpower Wiring 71 Providing / Fitting Ofthermal Overload Relay 72 Providing / Fitting Ofbus Bar 73 Providing / Fitting Ofboiled Fuse Link 74 Providing / Fitting Offuse Holder Suitable For Bolted Fuse Link 75 Making Ofincoming Power Connection To Main Switch / Mccb / Voltage Stabilizer And Checking On Full Load. 76 225 Amp. To 300 Amp. 77 Charges For Minor Repair / Servicing Of Lt Control Panel Including Minor Parts Like Meters, Indicators , Timers Etc 78 Providing / Fitting Ofcircuit Wiring 79 Providing / Fitting Ofvoltmeter 80 Providing / Fitting Of Ampmeter 81 Providing / Fitting Ofamp Selector Switch 82 Providing / Fitting Ofvolt Selector Switch 83 Providing / Fitting Ofindicator Lamps 84 Providing / Fitting Ofpush Button 85 Providing / Fitting Ofstar Delta Timer 86 Providing / Fitting Ofterminal Plate 87 Providing / Fitting Offault Analyzer 88 Providing / Fitting Ofquartz Timer 89 Providing / Fitting Ofdelay Timer 90 Providing / Fitting Ofpower Wiring 91 Providing / Fitting Ofthermal Overload Relay 92 Providing / Fitting Ofbus Bar 93 Providing / Fitting Ofboiled Fuse Link 94 Providing / Fitting Offuse Holder Suitable For Bolted Fuse Link 95 Making Ofincoming Power Connection To Main Switch / Mccb / Voltage Stabilizer And Checking On Full Load.. Last date of submission for this tender is 2021-07-30. This is a Bolts tender in Poonch, Jammu And Kashmir

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

3 issued
  • Tender Document 1pdf
  • Tender Document 2pdf
  • Tender Document 3html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in