Public Health Engineering Department
- AOC value
- Refer Docs
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Authority
- Public Health Engineering Department
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Public Health Engineering Department has published Item Rate Contract For Improvement / Replacement / Maintenance Of Parts Of Lt Control Panels For The Year 2021-22 In Respect Of Jal Shakti ( Phe ) Division Poonch.- 1 Disconnection Of Incoming Power Connection From Main Switch / Mccb / Voltage Stabilizer And Checking Of Fault 2 Making Of Temporary Arrangement For Running Of Pumping Machinery 3 Replacement Of Damaged Mnx 25 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 25 4 Replacement Of Damaged Mnx 40 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 40 5 Replacement Of Damaged Mnx 50 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 50 6 Replacement Of Damaged Mnx 70 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 70 7 Replacement Of Damaged Mnx 80 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 80 8 Replacement Of Damaged Mnx 95 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 95 9 Replacement Of Damaged Mnx 110 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 110 10 Replacement Of Damaged Mnx 185 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 185 11 Replacement Of Damaged Mnx 225 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 225 12 Replacement Of Damaged Mnx 250 By Way Of Providing / Fitting Of 3 Pole Power Contractor- Mnx 250 13 Replacement Of Damaged Kit Of Mnx 25 By Way Of Providing / Fitting Of New Kit 14 Replacement Of Damaged Kit Of Mnx 40 By Way Of Providing / Fitting Of New Kit 15 Replacement Of Damaged Kit Of Mnx 50 By Way Of Providing / Fitting Of New Kit 16 Replacement Of Damaged Kit Of Mnx 70 By Way Of Providing / Fitting Of New Kit 17 Replacement Of Damaged Kit Of Mnx 80 By Way Of Providing / Fitting Of New Kit 18 Replacement Of Damaged Kit Of Mnx 95 By Way Of Providing / Fitting Of New Kit 19 Replacement Of Damaged Kit Of Mnx 110 By Way Of Providing / Fitting Of New Kit 20 Replacement Of Damaged Kit Of Mnx 185 By Way Of Providing / Fitting Of New Kit 21 Replacement Of Damaged Kit Of Mnx 225 By Way Of Providing / Fitting Of New Kit 22 Replacement Of Damaged Kit Of Mnx 250 By Way Of Providing / Fitting Of New Kit 23 Replacement Of Damaged Mpr 24 Replacement Of Damaged Over Load Relay & P / F New Overload Relay 25 Replacement Of Damaged Under Load Relay & P / F New Underload Relay 26 Replacement Of Single Phase Relay & P / Fsingle Phase Relay 27 Replacement Of Reverse Phase Relay & P / Freverse Phase Relay 28 Replacement Of Damaged Mccb 100 By Way Of Providing / Fitting Ofmccb 100 Amp 29 Replacement Of Damaged Mccb 125 By Way Of Providing / Fitting Ofmccb 125 Amp 30 Replacement Of Damaged Mccb 200 By Way Of Providing / Fitting Ofmccb 200 Amp 31 Replacement Of Damaged Mccb 250 By Way Of Providing / Fitting Ofmccb 250 Amp 32 Replacement Of Damaged Mccb 400 By Way Of Providing / Fitting Ofmccb 400 Amp 33 Replacement Of Damaged Mccb 600 By Way Of Providing / Fitting Ofmccb 600 Amp 34 Replacement Of Damaged Mccb 100 By Way Of Providing / Fitting Ofmccb 100 Amp 35 Making Ofincoming Power Connection To Main Switch / Mccb / Voltage Stabilizer And Checking On Full Load. 36 Upto 100 Amp 37 Charges For Minor Repair / Servicing Of Lt Control Panel Including Minor Parts Like Meters, Indicators , Timers Etc 38 Providing / Fitting Ofcircuit Wiring 39 Providing / Fitting Ofvoltmeter 40 Providing / Fitting Of Ampmeter 41 Providing / Fitting Ofamp Selector Switch 42 Providing / Fitting Ofvolt Selector Switch 43 Providing / Fitting Ofpush Button 44 Providing / Fitting Ofindicator Lamps 45 Providing / Fitting Ofstar Delta Timer 46 Providing / Fitting Ofterminal Plate 47 Providing / Fitting Offault Analyzer 48 Providing / Fitting Ofquartz Timer 49 Providing / Fitting Ofdelay Timer 50 Providing / Fitting Ofpower Wiring 51 Providing / Fitting Ofthermal Overload Relay 52 Providing / Fitting Ofbus Bar 53 Providing / Fitting Ofboiled Fuse Link 54 Providing / Fitting Offuse Holder Suitable For Bolted Fuse Link 55 Making Ofincoming Power Connection To Main Switch / Mccb / Voltage Stabilizer And Checking On Full Load. 56 125 Amp. To 200 Amp 57 Charges For Minor Repair / Servicing Of Lt Control Panel Including Minor Parts Like Meters, Indicators , Timers Etc 58 Providing / Fitting Ofcircuit Wiring 59 Providing / Fitting Ofvoltmeter 60 Providing / Fitting Of Ampmeter 61 Providing / Fitting Ofamp Selector Switch 62 Providing / Fitting Ofvolt Selector Switch 63 Providing / Fitting Ofindicator Lamps 64 Providing / Fitting Ofpush Button 65 Providing / Fitting Ofstar Delta Timer 66 Providing / Fitting Ofterminal Plate 67 Providing / Fitting Offault Analyzer 68 Providing / Fitting Of Quartz Timer 69 Providing / Fitting Ofdelay Timer 70 Providing / Fitting Ofpower Wiring 71 Providing / Fitting Ofthermal Overload Relay 72 Providing / Fitting Ofbus Bar 73 Providing / Fitting Ofboiled Fuse Link 74 Providing / Fitting Offuse Holder Suitable For Bolted Fuse Link 75 Making Ofincoming Power Connection To Main Switch / Mccb / Voltage Stabilizer And Checking On Full Load. 76 225 Amp. To 300 Amp. 77 Charges For Minor Repair / Servicing Of Lt Control Panel Including Minor Parts Like Meters, Indicators , Timers Etc 78 Providing / Fitting Ofcircuit Wiring 79 Providing / Fitting Ofvoltmeter 80 Providing / Fitting Of Ampmeter 81 Providing / Fitting Ofamp Selector Switch 82 Providing / Fitting Ofvolt Selector Switch 83 Providing / Fitting Ofindicator Lamps 84 Providing / Fitting Ofpush Button 85 Providing / Fitting Ofstar Delta Timer 86 Providing / Fitting Ofterminal Plate 87 Providing / Fitting Offault Analyzer 88 Providing / Fitting Ofquartz Timer 89 Providing / Fitting Ofdelay Timer 90 Providing / Fitting Ofpower Wiring 91 Providing / Fitting Ofthermal Overload Relay 92 Providing / Fitting Ofbus Bar 93 Providing / Fitting Ofboiled Fuse Link 94 Providing / Fitting Offuse Holder Suitable For Bolted Fuse Link 95 Making Ofincoming Power Connection To Main Switch / Mccb / Voltage Stabilizer And Checking On Full Load.. Last date of submission for this tender is 2021-07-30. This is a Bolts tender in Poonch, Jammu And Kashmir
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
3 issued- Tender Document 1pdfPDF document
- Tender Document 2pdfPDF document
- Tender Document 3htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free