Power Development Department
- AOC value
- Refer Docs
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Authority
- Power Development Department
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Power Development Department has published Survey, Design, Supply, Transportation, Carriage, Erection, Testing And Commissioning Of 25Kva Sub Stations Along With Ht Taplineand Lt Line At Ballan Malikote, Brangla Malikote, Chungra Malikote, Lalori Gali Malikote, Kolan Malikote And Extension Of Lt Lines At Sisal Malikote, Chachi Malikote, Bani Malikote, Bagan Malikote In Sub Divisiondharmari Under Ut Capex Budget 2022-23 On Turnkey Basis In District Reasi”-2 9 mtr long Pole ST-410, SP33 3 GI V cross-arm with top Bracket including clamp 4 GI Channel X-arm including clamps and braces 5 11kV GO AB Swich set 3-Phase, 3-Pole, 200 Amp 6 ACSR Weasel Conductor 7 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 8 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 9 Galvinized Nuts and Bolts 10 Danger Plates with Clamps 11 Anti-Climbing Device with Clamps 12 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip (25x3)mm. 13 Aluminium Paint (Asian/Nerolac or reputed make) 14 Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole 15 Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete. 16 Supply, Fabrication,Erection, Testing and commissioning of 25KVA Distribution substation as per scope of work mentioned in SBD 17 11/0.433KV, 3-phase 25 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) and with LV cable box having detachable Aluminium Gland plate 18 9 mtr long Pole ST-410, SP33 19 Gapless Surge Arrestor, 9kV, 10kA, LA with polymer housing, Station type 20 11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, vertical type 21 11kV Horn Gap Fuse set 3-phase, 200 Amp 22 95sqmm Single Core PVC Cable 23 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 24 GI Channel/Angle/Flat ofdifferent sizes including clamps 25 Galvanised Nuts & Bolts 26 Earthing of s/stn - Excavation of earthing pit of dia 650mm & depth 3000mm, installation ofEarthing pipe of 40mm nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI strip for neutral earthing of size 25mm x 3mm for connection of transformer body, GO set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover 27 Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete 28 Danger Plates with clamps 29 G.I Barbed Wire for anti climbing 30 Bus bar insulator 31 Aluminium strip 50x10 mm 32 Cement bottoming 1:2:4 mix as per REC standards 0.5cum/Pole 33 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 34 Aluminium (Asian/Nerolac or reputed make) Paint 35 Laying of LT Line and extension of LT line as per scope of work mentioned in SBD 36 8 mtr long Pole ST-410, SP15 37 GI M Clamp for shackle Insulator 38 ACSR weasel Conductor 39 16 KN Polymer Shackle Insulators 40 Galvanised Nuts & Bolts 41 Danger Plates with clamps 42 Earthing Complete by GI Pipe 40mm or GI Rod 20 mm 2.5 Meter long through GI Strip(25x3)mm 43 Aluminium Paint (Asian/Nerolac or reputed make) 44 Anti-Climbing Device with Clamps 45 Cement Bottoming 1:2:4 mix as per REC Standards 0.45CUM/Pole 46 Galvanised Stay setwith 50x8mm stay clamp, Guy Insulator (2 Nos), Anchor Plate (200x200x6mm) nuts and Bolts, 2Nos Turn Buckles, 1.8 long, 16mm diameter solid GS Stay rod & 7/3.15mm dia GI Standard wire complete . Last date of submission for this tender is 2022-10-05. This is a Bolts tender in Reasi, Jammu And Kashmir
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
3 issued- Tender Document 1pdfPDF document
- Tender Document 2pdfPDF document
- Tender Document 3htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free