🎉 Your free trial plan has started. Plan will expire in 0 days

Himachal Pradesh State Electricity Board

Apparel And Personal Care
chamba, himachal pradesh
AOC Value₹6.86 Lac
AOC Date25 Jul 2022
Completion DaysRefer Docs
Bid AmountRefer Docs

Important Info

Result ID
Refer Docs
Award of Contract
25/07/2022
Authority
Himachal Pradesh State Electricity Board
Published Date
Refer Docs
Tender Closing Date
Refer Docs
Tender No
55(00)/2025-2026/XXX/5XX
Bidding URL
https://www.exampletenders.gov.in/bid/98765
Tender
View Tender
Bidder Details
Bidder Name: Mr. Jhon Doe, Ranking 2

AOC Description

Himachal Pradesh State Electricity Board has published Tender for Supply of equipment / material , design, erection, testing & commissioning for SOP to Indian Meteorological Departmentby Prov. 11/.4 KV 63 KVA S/Stn. a/w 11 KV HT and LT line for Doppler WeatherRaddar at Vill. Jotin section Chowari-I under ESD Chowari ED Dalhousie ( T.S. No. 232/21-22 )(BID No. OCD/DB/Bid-23/2022-23) Sl. No. Item Description 1 Supply of 11/.4 KV 63 KVA DISTRIBUTION SUB STATION 2 11/.4 KV 63KVA DTR (REC Sep. ord 11/1976 3 Prov. ST PolePole 9 Mtr. Long W/L 200 Kgs 4 Muff for steel tubular pole with concrete filling 5 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 6 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 7 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 8 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 9 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 10 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 11 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 12 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 13 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 14 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 15 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 16 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 17 D.O Fuse unit 18 Surge Arrester, 9 kV Station Class 19 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 20 Stay set complete 21 Staywire (7/3.15mm)( 7 Kg per stay set) 22 Pipe earthing with GI,Charcoal & Salt 23 Prov. LT distribution panel with MCCB (40 A, 36 KA, 4P,1 No.) & SFU (16A 4 No. rewireble) for 63KVA Trf. as per specification 24 Half clamp (M.S. Flat 50x6) 25 Full clamps (M.S. Flat 50x6) 26 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 27 Aluminium Thimbles 28 Copper Thimble 29 Danger Plate 30 Barbed wire (REC Sp F 3/1981) 31 LT Cable 3-1/2 core-120mm sq. 32 Alluminium Paint 33 Prov.ACSR, 6/1/3.35 mm 34 Prov. Transformer structure protection plinth(Civil Work As per HPSR) for 63KVA S/Stn 35 Erection of 63 kVA S/Stn 36 11/.4 KV 63KVA DTR (REC Sep. ord 11/1976 37 Prov. ST PolePole 9 Mtr. Long W/L 200 Kgs 38 Muff for steel tubular pole with concrete filling 39 X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 2 Nos] for incomer line 40 MS A.I.(50X50x6 mm), Length: 2800 mm x(1 Nos for LAs ) 41 X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch 42 X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for transformer bed 43 X-Arm [Channel Iron (100x50x6 mm), Length : 460 mm x 2 Nos for supporting Main Channel of Transformer] 44 MS A.I.(50X50x6 mm), Length: (2800 mm) x 2 No. 45 MS Angle Iron (35X35x5 mm), Length : 460 mm x 2 Nos 46 MS A.I.(50X50x6 mm), Length: (950 mm) x 2 Nos. of bed knee bracing 47 MS Angle Iron (50X50x6 mm), Length : (2800 mm) x2 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 48 MS Angle Iron (50X50x6 mm), Length : (450 mm)x1 Nos for Transformer LT Distribution Box and G.O switch fixing assembly 49 G.O. Switch handle supporting: [C.I. (75x40x6mm), length: 460mm for Transformer LT Distribution Box and G.O switch fixing assembly 50 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 51 D.O Fuse unit 52 Surge Arrester, 9 kV Station Class 53 Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.) 54 Stay set complete 55 Staywire (7/3.15mm)( 7 Kg per stay set) 56 Pipe earthing with GI,Charcoal & Salt 57 Prov. LT distribution panel with MCCB (40 A, 36 KA, 4P,1 No.) & SFU (16A 4 No. rewireble) for 63KVA Trf. as per specification 58 Half clamp (M.S. Flat 50x6) 59 Full clamps (M.S. Flat 50x6) 60 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 61 Aluminium Thimbles 62 Copper Thimble 63 Danger Plate 64 Barbed wire (REC Sp F 3/1981) 65 LT Cable 3-1/2 core-120mm sq. 66 Alluminium Paint 67 Prov.ACSR, 6/1/3.35 mm 68 Prov. Transformer structure protection plinth(Civil Work As per HPSR) for 63KVA S/Stn 69 Supply of 11 kV HT line 70 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 71 Prov. Steel tubular poles. 9mtrs 72 Muff for steel tubular pole (2000mm long) with concrete filling 73 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 74 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 75 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 76 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 77 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 78 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 79 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 80 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 81 Eye Hook for earth wire 82 Earth Wire Clamp 83 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 84 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 85 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 86 Danger Plate (250X200X1.6 mm) 87 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 88 Barbed wire (REC Sp F 3/1981) 89 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 90 Alluminium Paint 91 Erection of 11 kV HT line 92 ACSR 6/1/3.35 (55mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} 93 Prov. Steel tubular poles. 9mtrs 94 Muff for steel tubular pole (2000mm long) with concrete filling 95 Belt Set - MS Angle Iron: 50x50x6, Length [1800 mm x 2 No.]for Dead End Structures 96 X-Bracing Set - MS Angle Iron: 50x50x6, Length [2125 mm x2 No.] for Dead End Structures 97 X-Arm(Horizental) - MS C. Iron: 50x50x6, Length [2340 mm x2 No.]for Dead End Structures 98 Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)for Dead End Structures 99 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure for Dead End Structures 100 Stay set complete in all respect ( Single Pole-1No. , /D. Pole Structures-4Nos.) 101 Stay Wire (7/3.15 mm) (8.0 kg Per Stay Set) 102 Single Continous Earth wire (GI, 8 SWG) {alongwith 1 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m 103 Eye Hook for earth wire 104 Earth Wire Clamp 105 MS Chanel Iron 75x40x6mm, length: 2400mm for road crossing/G.O Switch 106 Half clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 107 Full clamp (on D/P dead end str:4Nos; on Run Through Str. 2Nos.) 108 Danger Plate (250X200X1.6 mm) 109 M. S. Nuts & Bolts off sizes (Galvanised coated) [prefarably 16mm Ø or more (with flat and spring washer) 110 Barbed wire (REC Sp F 3/1981) 111 G.O AB switch unit (11KV,400,663KA) Tripple pole O/D type 112 Alluminium Paint 113 Supply of LT line 114 ACSR 6/1/3.35 mm sq. 115 Steel Pole 8Mtr. Long (1800mm long) 116 Muff for steel tubular pole 117 Shackle insulators (16KN) (RECD-3/761)(ISS No 1445/1977) 118 D-iron (U-Clamp) (RECD-4/79)(ISS No 7935/1975) 119 Earth Knob 120 LT Saty Set Complete With Satywire REC No 31/1983 121 Prov. Full clamp 122 Coil Earthing (spec J-1/72) 123 G.I.Wire No 8 SWG Earth wire1.03km (Sep.G-2/72) for suporting cable 124 Spool Tie 125 M.S.Nuts & Bolt off Sizes 126 Aluminium paint 127 Erection of LT line 128 ACSR 6/1/3.35 mm sq. 129 Steel Pole 8Mtr. Long (1800mm long) 130 Muff for steel tubular pole 131 Shackle insulators (16KN) (RECD-3/761)(ISS No 1445/1977) 132 D-iron (U-Clamp) (RECD-4/79)(ISS No 7935/1975) 133 Earth Knob 134 LT Saty Set Complete With Satywire REC No 31/1983 135 Prov. Full clamp 136 Coil Earthing (spec J-1/72) 137 G.I.Wire No 8 SWG Earth wire1.03km (Sep.G-2/72) for suporting cable 138 Spool Tie 139 M.S.Nuts & Bolt off Sizes 140 Aluminium paint . Last date of submission for this tender is 2022-07-01. This is a Coats And Jackets tender in Chamba, Himachal Pradesh

Insurance Surety Bond

Fast, Reliable & Accepted for EMD/PBG

  • Zero BG Limit Impact
  • Accepted in All Tenders
  • Quick Online Quote

Tender Documents

  • Tender Document 1html
lock-red

Unlock the Tender details for free

description-svgrepo

Bidder Details

Bidder NameTechnical BidFinancial BidAOCBid ValueRank
Sharma infra projects pvt ltd
₹1,24,50,000.00L1
Verma constructions ltd
₹1,31,00,000.00L2
Nair engineering works
₹1,38,75,000.00L3
Iyer industrial solutions
₹1,43,20,000.00L4
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in