🎉 Your free trial plan has started. Plan will expire in 0 days

State Bank Of India

gurugram, haryana

AOC value
₹8.72L
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

State Bank Of India has published Bids Are invited for Loss Prevention Active And Passive Fire Protection Systems Fire Door - Providing, Fixing, Testing And Commissioning Of Two Hour Fire-Rated Single/Double Panel Door & Door Frame According To Approved Design & Shop Drawing Door Frame Made Using 1.2 Mm Thick Galvanized Steel Sheet Conforming Is 277 For Formed To Single Rebate Profile Of Size 100Mmx50mm & With Maximum Bending Radius Of 1.4 Mm. Door Frame With Mitred Joints To Have 40Mm Width All Around The Lobby Side. Frame To Be Provided With Back Plate Bracket For Installation Using Anchors. The Frame To Be Fixed Using 8Mm Expansion Anchors (Hilti/Equivalent) As Per Approved Design. Rate To Also Include Providing, Erecting & Fixing Single/Double Leaf Minimum 44Mm Thick Metal Finish Door Shutter Constructed From 0.8Mm Thick Galvanized Steel (Gpsp) Sheet Conforming Is 277, Fully Flush, Double Skin Door Shell With Lock Seam Joints And Stile Edges, Internal Reinforcements Provided At Top, Bottom & Stile Edges For Fire Rating. The Internal Construction Of The Door Should Be A Resin-Bonded Specially Designed Honeycomb Structure With Reinforcements At Top, Bottom & Stile Surrounds. Doors Shall Be Factory Prepped For Receiving Specified Hardware. Vision Panel, Where Specified, Shall Be 6Mm Thick Clear 2 Hour Fire Rated Glass. The Door Assembly Shall Be Fire Rated For 120 Minutes , A - Double Door , B - Single Door , Fire Rated Paint - Fire Rated Paints For All Partition Wall Are Specialized Intumescent Coating That Swell When Exposed To High Heat, Forming A Thick, Char-Like Barrier For 30 To Over 120 Minutes. Ensure The Paint Complies With Local Fire Safety Codes, Such As Bs 476, Din En 13501,Or Astm. Varies By Product With Some Providing 10-12 Sq.M/Ltr. , Fire Suppression System - Supplying, Installation, Testing And Commissioning Of 58.5Kg Cylinder/Valve Assembly. , B - Supplying, Installation, Testing And Commissioning Of Novec 1230 - Agent Filled In The Above Cylinder. , C - Supplying, Installation, Testing And Commissioning Of Master Valve With Automatic Cum Manual Actuator, Including Trim Complete With All Accessories. , D - Supplying, Installation, Testing And Commissioning Of Slave Valve With Actuator, Including Trim Complete With All Accessories. , E - Supplying, Installation, Testing And Commissioning Of Actuation Hose , F - Supplying, Installation, Testing And Commissioning Of Discharge Hose , G - Supplying, Installation, Testing And Commissioning Of Nrv , H - Supplying, Installation, Testing And Commissioning Of 58.5 Kg Cylinder Strap. , I - Supplying, Installation, Testing And Commissioning Of Nozzles , J - Supplying, Installation, Testing And Commissioning Of Warning Sign Stickers. , K - Supplying, Installation, Testing And Commissioning Of Astm Schedule 40(Seamless Pipe) (A106 Grade B) , K I - I) 25Mm (6.2 Mm) , K Ii - Ii) 32Mm (Header) (8 Mm Minimum) , Fire Alarm And Detectors - Supply, Installation, Testing & Commissioning Of 1 Zone Gas Release Panel (Control Panel) , B - Supply, Installation, Testing & Commissioning Of Smoke Detector , C - Supply, Installation, Testing & Commissioning Of Abort Switch. , D - Supply, Installation, Testing & Commissioning Of Manula Call Points. , E - Supply, Installation, Testing & Commissioning Of Electronic Strobe With Hooter. , F - Supply And Laying Of Frls Armoured Cable 2Cx1.5 Sqmm , Portable Fire Extinguishers - Supply And Installing Isi Marked As Per 15683 Fire Extinguisher, Carbon-Di-Oxide Type Capacity 4.5 Kgs Complete In All Respect. , B - Supply And Installing Abc (Powder Type) Fire Extinguisher Mild Steel Cylinders Isi Complete Confirming To Is 15683. , C - 6 Kgs. , D - 2 Kgs. , E - Supply, Installation, Testing And Commissioning Of Exit Sinage Of Photo Luminescent On Aluminium Sheet Of 1.0 Mm Containing Lumigen-Iii As Base Chemical, Covered With Uv Stabilized Coating Size 450 X 200. Total Quantity : 1003. Last date of submission for this tender is 2026-06-05. This is a Fire Protection System tender in Gurugram, Haryana

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in