Power Grid Corporation Of India Limited
- AOC value
- ₹3.66L
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Power Grid Corporation Of India Limited has published Bids Are invited for BACPAC ETHERNET MOD 1.5K PT (Part Code: 4100-6069) - a. Communication Protocol Reference: 1. BACnet Internet Protocol (IP) or BACnet MS/TP (serial) Reference ANSI/ASHRAE Standard 1352. Modbus TCP or Modbus RTU (serial)b. Compatibility: 1. The Module Should be Compatible with Simplex 4100 ES Fire Alarm Control Units (FACU)2. The Module should be compatible with Metasys®, Johnson Controls building automation system for 4100ES and 4010ES panels , 4100ES MSTR CTLR UPGD NO DSPLY (Part Code: 4100-7158) - a. Compatibility: 1. The Card Should be Compatible with Simplex 4100 ES Fire Alarm Control Units (FACU) , SPS POWER, 3 NACS, 220/240V (part Code: 4100-5113) - a. Compatibility: 1. The card should be compatible with power supply input of 220-240V AC, 50Hz2. The module should have three class A/B NACs, IDNet Channel & Charger – 220/230/240 VAC 50/60Hz (mounts to PDI) , DUAL RS-232 IF CARD (Part Code: 4100-6038) - a. Compatibility: 1. The Card Should be Compatible with Simplex 4100 ES series Fire Alarm Control Units (FACU)2. The card should be able to connect devices with a standard RS-232 interface(such as an AC or DC Printer, CRT, third-party computer, or GCC) to the 4100.3. The card should be able to connect a Simplex 2120 FACP to a 4100 system, using either an 18 AWG (0.8231 sq mm) hardwired connection (maximum distance 10,000 feet [3,048m]) or FSK-type modems , INFOALARM DISPLAY ASSY FOR 4100ES MOUNT (Part Code: 4100-7153) - a. Features: Includes complete bay front assembly with InfoAlarm Command Center providing raised keys with fixed labels; uses existing power supply and Master Controller Board (CPU card)b. Compatibility: 1. The Module Should be Compatible with Simplex 4100 ES series Fire Alarm Control Units (FACU) , RUI+ CPU/MTHR BD FOR SPS (Part Code: 743-2265) - a. Compatibility: 1. The Module Should be Compatible with Simplex 4100 ES series Fire Alarm Control Units (FACU) , VESDA INTERFACE KIT (Part Code: 4100-6048) - a. Features: Intelligent. Last date of submission for this tender is 2021-12-23. This is a Building Management System tender in null, Haryana
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
1 issued- Tender Document 1htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free