🎉 Your free trial plan has started. Plan will expire in 0 days

Military Engineer Services

ge (af) sirsa, haryana

AOC value
₹6.08L
AOC date
20 Jul
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 20 Jul 20AOC date

Important info

Result ID
Refer Docs
Award of contract
20/07/2020
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Military Engineer Services has published Ge/Sra-35 Of 2019-2020 As Per Boq , Annual Maintenance Contract For Fire Fighting System , Fire Alarm & Fire Detection System At Atc , Complete All As Specified And As Directed Comprising Of The Following :-Fire Fighting System :- ( A ) Fire Fighting Panel - 01 No . ( B ) Jockey Pump 10 Hp - 01 No . ( C ) Electric Driven Pump 75 Hp - 01 No . ( D ) Diesel Engine Driven Pump 75 Hp - 01 No . ( E ) Fire Hydrant Landing Valve - 16 No . ( F ) Hose Box - 10 No . ( G ) Branch Pipe - 10 No . ( H ) Hose Reel Drum - 10 No . ( J ) Hose 15 Metre Long - 10 No . ( K ) Fire Hydrant Stand Post - 06 No . ( L ) Ci Sluice Valve 80Mm - 05 No . ( M ) Fire Brigade - 01 No . ( N ) Ci Non Return Valve 100Mm-05 No . ( O ) Ci Foot Valve 100Mm - 03 No . ( P ) Ms Erw Pipe 150Mm - 185 Rm ( Q ) Ms Erw Pipe 100Mm - 209 Rm ( R ) Ms Erw Pipe 80Mm - 95 Rm ( S ) Gi Heavy Duty Pipe 80Mm - 12 Rm ( T ) Gi Heavy Duty Pipe 40Mm - 190 Rm ( U ) Gi Heavy Duty Pipe 25Mm - 160 Rm ( V ) Sprinkle Glass Tube Type - 92 No . ( W ) Sprinkle Glass Tube Upright Type- 59 No . Fire Detection & Alarm System :- ( A ) Fire Alarm Control Panel Four Loop - 01 No . ( B ) Fire Alarm Control Panel Two Loop - 05 No . ( C ) Smoke Detectors - 58 No . ( D ) Heat Detectors - 58 No . ( E ) Manual Call Point - 14 No . ( F ) Control Module - 59 No . ( G ) Fault/ Short Circuit Isolator - 05 No . ( H ) Remote Response Indicator - 116 No ( J ) Pvc Conduit Pipe 25Mm - 850 Rm ( K ) Copper Flexible Wire - 1660 Rm , Annual Maintenance Contract For Fire Alarm & Fire Detection System At Wsa , Complete All As Specified And As Directed Comprising Of The Following :-Fire Detection & Alarm System :- ( A ) Fire Alarm Control Panel Four Loop - 01 No . ( B ) Fire Alarm Control Panel Two Loop - 05 No . ( C ) Smoke Detectors - 58 No . ( D ) Heat Detectors - 58 No . ( E ) Manual Call Point - 14 No . ( F ) Control Module - 59 No . ( G ) Fault/ Short Circuit Isolator - 05 No . ( H ) Remote Response Indicator - 116 No . ( J ) Pvc Conduit Pipe 25Mm - 850 Rm ( K ) Copper Flexible Wire - 1660 Rm , Annual Maintenance Contract For Lift Of 08 Passenger/ 544 Kg At Atc As Per Terms And Conditions Given As Follows :- ( A ) Servicing Of Lift At Regular Intervals And As Frequently As The Company Deems Necessary Based On The Age , Nature And Condition Of The Elevator And Take All Reasonable Care And Maintaining Of Lift Equipment In Safe And Proper Working Condition . ( B ) Carry Out The Servicing Work As Required Whenever Possible On A Day Including Sundays & Holidays And During Regular Working Hours . ( C ) Replenish The Gear And Motor Bearing With Necessary Manufacturer Recommended Lubricants Whenever Necessary And All Parts Of The Lift Will Be Checked , Cleaned And Lubricated To Keep Them , Both Mechanically And Electrically In Perfect Working Condition . Replacement Of Unserviceable Parts Will Be Included In Quoted Unit Rate . ( D ) Carry Out According To Its Standards Customary Annual Safety Test To Examine All Safety Devices . ( E ) Lift Amc Will Be As Per Terms And Conditions Of Schindler Company . ( F ) Contractor Has To Submit Amc Within 20 Days After Acceptance Of Tender . If The Contractor Fails Then Necessary Recovery Will Be Made As Per Terms And Conditions Of The Contract . Note : Contractor Is Responsible For Working And Inspection Of Registration For The Year 2019-20 Of Lift By Lift Inspector Cum Executive Engineer , Electrical Inspectorate , Haryana - Hisar Is Included In Quoted Unit Rate . , Annual Maintenance Contract For Lift Of 06 Passenger/ 408 Kg At Smc As Per Terms And Conditions Given As Follows :- ( A ) Servicing Of Lift At Regular Intervals And As Frequently As The Company Deems Necessary Based On The Age , Nature And Condition Of The Elevator And Take All Reasonable Care And Maintaining Of Lift Equipment In Safe And Proper Working Condition . ( B ) Carry Out The Servicing Work As Required Whenever Possible On A Day Including Sundays & Holidays And During Regular Working Hours . ( C ) Replenish The Gear And Motor Bearing With Necessary Manufacturer Recommended Lubricants Whenever Necessary And All Parts Of The Lift Will Be Checked , Cleaned And Lubricated To Keep Them , Both Mechanically And Electrically In Perfect Working Condition . Replacement Of Unserviceable Parts Will Be Included In Quoted Unit Rate . ( D ) Carry Out According To Its Standards Customary Annual Safety Test To Examine All Safety Devices . ( E ) Lift Amc Will Be As Per Terms And Conditions Of Johnson Company . ( F ) Contractor Has To Submit Amc Within 20 Days After Acceptance Of Tender . If The Contractor Fails Then Necessary Recovery Will Be Made As Per Terms And Conditions Of The Contract . Note : Contractor Is Responsible For Working And Inspection Of Registration For The Year 2019-20 Of Lift By Lift Inspector Cum Executive Engineer , Electrical Inspectorate , Haryana - Hisar Is Included In Quoted Unit Rate . . Last date of submission for this tender is 2020-06-20. This is a Packaging Tubes And Label tender in Ge (af) Sirsa, Haryana

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

No Documents Found

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in