Lala Lajpat Rai University Of Veterinary And Animal Sciences
hod, vpa, luvas, hisar, haryana
- AOC value
- ₹7L
- AOC date
- 24 Jan
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- 24 Jan 22AOC date
- -Published
- -Closes
- -Bid opens
- 24 Jan 2022AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- 24/01/2022
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Lala Lajpat Rai University Of Veterinary And Animal Sciences has published Purchase Of Refrigerated Centrifuge For The Department Of Vpa Purchase Of Refrigerated Centrifuge For The Department Of Vpa , Refrigerated Centrifuge Maximum Speed Of 25, 830 X G / 15200 Rpm With 1.5 / 2Ml Rotor, With A Brushless Motor ? Low Speed Down To 100 Rpm For Low Speed Applications ? Microprocessor Controlled Refrigratedcentrifuge ? Temperature Range Should Be From -10°C To 40°C ? It Should Be Able To Maintain 4°C At The Maximum Speed. ? It Should Be Possible To Use Aerosol Tight Rotor; Aerosol Tightness Of Rotor Should Be Certified By A Third Party Agency. ? Smooth Centrifuge Bowl Made Of Rust Free Material ? Window In Lid For Independent Speed Checking ? Instrument Should Be Able To Accommodate 30 X 2 Number Of 1.5 / 2Ml Tubes. ? Instrument Should Have An In-Built Condensate Drain To Prevent Water Accumulation. ? It Should Be Possible To Perform A Fast Pre-Cooling Of The Instrument Using A Dedicated Fast Temp Function. ? Acceleration Curves : 09Deacceleration :10, Free Run Out ? Timer ( S; H:Min ) 10 Secto 99 Hrs 59 Min ? It Should Be Possible To Store Minimum Of 05 Programs Via Push Button And High Contrast Lcd Interface ? Speed Setting Should Be Possible In Both Rpm And Rcf. ? It Should Provide With Aluminium Rotor. ? Should Have The Option To Accommodate Rotors For Different Formats Of Tubes Starting From 1.5 / 2.0Ml Pcr Tubes Up To 15Ml, 50 Ml, 85 Ml Centrifuge Tubesand 96 Welled Elisa Plates. ? Instrument Should Have Automatic Rotor And Imbalance Recognition Facility To Automatically Recognize And Set Maximum Speeds Upon Rotor Change. ? Rotor Lids Should Have A Quick Lock-System For Secure Lid Closing And Opening. ? It Should Be Possible To Perform Gentle Acceleration And Deceleration Using Dedicated Key ? Noise Levels Should Be ?54 Db ( A ) ? It Should Be Possible To Operate The Centrifuge At Set Rpm, For Short Spin Protocols. ? Machine Should Be Provided With Two Rotors: 1. Fixed Angle Rotor For 6 X 50 Ml With 6 X15ml Suitable Adapters And Should Able To Accommodate 5Ml Tubes With Certified Click Seal Biocontainment Lid. 2. Fixed Angle Rotor For 30X2 - 1.5 / 2.0 Ml Tubes With Certified Click Seal Biocontainment Lid Min Of Rcf: 25, 830 X G / 15200 Rpm. ? Instrument Should Be Certified With En / Ul / Iec 61010-1, En / Ul / Iec 61010-2-020 And 61010-2-101, Ul Listed / Ce Certified / Ivd Compliance / Certified Biocontainment ( Attach Certificates ) . ? Warranty: Three Year ? Should Be Quoted With Suitable Servo Voltage Stabilizer ( Either Inbuilt Or Included ) Of 2 Kva ? The Quoted Model Of The Instrument Must Have Been Supplied In A Minimum Of 10 Government Institutes In Last 3 Years. The User Reserves The Right To Verify The Usability, Spare Parts Availability And Maintenance Of The Equipment. ? The Spare Parts Of The Instruments Must Be Made Available For A Period Of 10 Years From The Date Of Submission Of Tender.. Last date of submission for this tender is 2021-10-21. This is a Spare Part tender in Hod, Vpa, Luvas, Hisar, Haryana
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
1 issued- Tender Document 1htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free