Indian Oil Corporation Limited
- AOC value
- Refer Docs
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Authority
- Indian Oil Corporation Limited
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Indian Oil Corporation Limited has published Supply Of Traps And Assemblies Supply Of Traps And Assemblies For P25 Project At Iocl Panipat Refinery , Supply Of Traps And Assemblies As Per Material Requisition , Thermo. Steam Trap,Cs (Ibr), 800,0, Mfg. Std., Sw Ends,B16.11, Thermodynamic Steam Trap, Refer Doc.6745-Pip-000-Ec-253, A105n, Internal Ss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required , Thermo. Steam Trap,Cs (Ibr), 800,0, Mfg. Std., Sw Ends,B16.11, Thermodynamic Steam Trap, Refer Doc.6745-Pip-000-Ec-253., A105n, Internal Ss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required , Liquid Drain Trap,Cs,(Nace), 150,0, Mfg Std, Flgd B16.5,Rf, Ball Float Type, Liquid Drain Trap For, 1St Stage Discharge, Refer Doc.6745-Pip-000-Ec-0365, A216 Gr.Wcb/A105n, (Nace), Internals Ss 316, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Nace Req. Acc. To Nace Mr-0103, And Doc. 6745-Pip-000-Ec-0005 , Liquid Drain Trap,Cs(Nace), 150,0, Mfg Std, Flgd B16.5,Rf, Ball Float Type, Liquid Drain Trap For, 1St Stage Suction., Refer Doc.6745-Pip-000-Ec-0365, A216 Gr.Wcb/A105n, (Nace), Internals Ss 316, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Nace Req. Acc. To Nace Mr-0103, And Doc. 6745-Pip-000-Ec-0005 , Liquid Drain Trap,Cs,(Nace), 150,0, Mfg Std, Flgd B16.5,Rf, Ball Float Type, Liquid Drain Trap For, 2Nd Stage Suction, Refer Doc.6745-Pip-000-Ec-0365, A216 Gr.Wcb/A105n, (Nace), Internals Ss 316, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Nace Req. Acc. To Nace Mr-0103, And Doc. 6745-Pip-000-Ec-0005 , Liquid Drain Trap,Cs,(Nace), 300,0, Mfg Std, Flgd B16.5,Rf, Ball Float Type, Liquid Drain Trap For, 2Nd Stage Discharge, Refer Doc.6745-Pip-000-Ec-0365, A216 Gr.Wcb/A105n, (Nace), Internals Ss 316, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Nace Req. Acc. To Nace Mr-0103, And Doc. 6745-Pip-000-Ec-0005 , Ball Float Trap,Cs (Ibr), 600,0, Mfg. Std., Flgd,B 16.5,Rf, Refer Doc.6745-Pip-000-Ec-0120, With Thermostatic Vent, A105n/A216 Gr.Wcb, Internalsss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required , Ball Float Trap,Cs (Ibr), 150,0, Mfg. Std., Flgd,B16.5,Rf, Refer Doc.6745-Pip-000-Ec-0120, With Thermostatic Vent, A105n/A216 Gr.Wcb, Internalsss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required , Ball Float Trap,Cs (Ibr), 150,0, Mfg. Std., Flgd,B16.5,Rf, Refer Doc.6745-Pip-000-Ec-0120, With Thermostatic Vent, A105n/A216 Gr.Wcb, Internalsss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required , Ball Float Trap,Cs (Ibr), 150,0, Mfg. Std., Flgd,B16.5,Rf, Refer Doc.6745-Pip-000-Ec-0120, With Thermostatic Vent, A105n/A216 Gr.Wcb, Internalsss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required , Ball Float Trap,Cs (Ibr), 150,0, Mfg. Std., Flgd,B16.5,Rf, Refer Doc.6745-Pip-000-Ec-0120, With Thermostatic Vent, A105n/A216 Gr.Wcb, Internalsss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required , Ppppu,Cs (Ibr), 150,0, Mfg. Std., Refer Doc.6745-Pip-000-Ec-0254, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required , Supply Of Traps And Assemblies As Per Material Requisition , Compact Steam Trap,Cs (Ibr), 800,0, Mfg. Std., Sw Ends,B16.11, Compact Trap Assembly With, Inbuilt Strainer,Thermodynamic, Trap,Bypass,Vent,Test Valves., Refer Doc.6745-Pip-000-Ec-0029, A105n, Internal Ss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required , Compact Steam Trap,Cs (Ibr), 800,0, Mfg. Std., Sw Ends,B16.11, Compact Trap Assembly With, Inbuilt Strainer,Thermodynamic, Trap,Bypass,Vent,Test Valves., Refer Doc.6745-Pip-000-Ec-0029, A105n, Internal Ss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required , Compact Steam Trap,Cs, 800,0, Mfg. Std., Sw Ends,B16.11, Compact Trap Assembly With, Inbuilt Strainer,Thermostatic, Trap,Bypass,Vent,Test Valves, Ref Doc. 6745-Pip-000-Ec-0361, A105n, Internal Ss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002 , Compact Steam Trap,Cs (Ibr), 800,0, Mfg. Std., Sw Ends,B16.11, Compact Trap Assembly With, Inbuilt Strainer,Thermodynamic, Trap,Bypass,Vent,Test Valves., Refer Doc.6745-Pip-000-Ec-0029, A105n, Internal Ss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required , Compact Steam Trap,Cs (Ibr), 800,0, Mfg. Std., Sw Ends,B16.11, Compact Trap Assembly With, Inbuilt Strainer,Thermodynamic, Trap,Bypass,Vent,Test Valves., Refer Doc.6745-Pip-000-Ec-0029, A105n, Internal Ss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required , Compact Steam Trap,Cs, 800,0, Mfg. Std., Sw Ends,B16.11, Compact Trap Assembly With, Inbuilt Strainer,Thermostatic, Trap,Bypass,Vent,Test Valves, Ref Doc. 6745-Pip-000-Ec-0361, A105n, Internalss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002 , Compact Steam Trap,Cs (Ibr), 800,0, Mfg. Std., Sw Ends,B16.11, Compact Trap Assembly With, Inbuilt Strainer,Thermodynamic, Trap,Bypass,Vent,Test Valves., Refer Doc.6745-Pip-000-Ec-0029, A105n, Internal Ss304, Add. Information, 1.For General Technical Requirements, Refer Doc. 6745-Pip-000-Ec-0002, 2.Ibr Certificate In Form Iiic Required => Limited. Last date of submission for this tender is 2025-10-06. This is a Steam Traps tender in Panipat, Haryana
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
2 issued- Tender Document 1htmlHTML document
- Tender Document 2pdfPDF document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free