🎉 Your free trial plan has started. Plan will expire in 0 days

Haryana Urban Development Authority

narnaul, haryana

AOC value
₹1.97L
AOC date
27 Jan
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 27 Jan 25AOC date

Important info

Result ID
Refer Docs
Award of contract
27/01/2025
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Haryana Urban Development Authority has published Tender For Annual Maintenance Estimate Of Master Water Supply Scheme In U/E , Narnaul For He Year For The Year 2024-2025- Annual maintenance estimate of Master Water Supply Scheme in U/E , Narnaul ,`` Replacing of old damaged acc water supply pipeline near plot no 735 , construction of haudi around sluice valve in sector-1 Narnaul and other works contingent thereto`` Sl. No. Item Description 1 [11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) 2 [20.11.2]Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriageloading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-incharge 2. 100 mm i/d 3 [20.11.3]Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriageloading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-incharge 3. 150 mm i/d 4 [20.11.4]Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriageloading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-incharge 4. 200 mm i/d 5 [20.11.5]Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriageloading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-incharge 5. 250 mm i/d 6 [6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor four level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size 7 [6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shallbe measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints,spacer bars, chairs, stays, hangers and annealed steel wireor other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. ThermoMechanically Treated bars of grade Fe-500D or more 8 [7.20.1]Brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) 9 [Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (D) ISI marked K-9grade SandS pipes as per 15:8329-2000 (amended up to date), with internal cement mortar lining for potablewater with rubber ring (EPDM/SBR) joints as per IS:1985 (excuding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/W to be measured I and paid separately.100mm i/d . Last date of submission for this tender is 2025-01-23. This is a Water Supply Project tender in narnaul, Haryana

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

7 issued
  • Tender Document 1html
  • Tender Document 2pdf
  • Tender Document 3xlsx
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
  • Tender Document 7pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in