🎉 Your free trial plan has started. Plan will expire in 0 days

Haryana Urban Development Authority

hisar, haryana

AOC value
₹11.51L
AOC date
2 Dec
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 2 Dec 25AOC date

Important info

Result ID
Refer Docs
Award of contract
02/12/2025
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Haryana Urban Development Authority has published tender for Providing and Fixing of 200 KVA Pole MountedTransformers in replanned site reserved for EWS Near Boosting Station in Sector-14 P-II at Hisar.(Including 6 years defect liability period for transformers and 3 years mtc. and defect liability period for all other items free of cost ). -- 1 24.1.1EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] 2 24.1.2EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] 3 24.1.6EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. [Through Rate] 4 Job WorkSupply, installation, testing, commissioning of 3 Phase 11KV/0.433 KV-250V, 200 KVA Oil immersed, naturally cooled, Aluminum Wound Outdoor type Distribution Transformers with CSP (Completely self protected ) features with external microprocessor based four pole MCCB 300Amp. To 400Amp., 50kA strictly conforming to Nigam’s technical specification No. CSC-V/R-I/DH/UH/P and D/2010-2011 read with amendment thereof and as per relevant ISS as amended from time to time and losses conforming to 4 star rating of BEE as per Appd. Make and Specification of DHBVN/UHBVN including installation of transformer on existing platform upto the entire satisfaction of Engineer-in-Charge.Valtage Rated Frequency Permitted at 75ºCi) Maximum load looses at 50% load at 75ºC = 780 Watt ii) Maximum losses at 100% load at 75ºC = 2300 Wattiii) Warranty = 78/72 Months shall be one time The above losses are maximum allowable and there would not be any positive tolerance. 5 Job WorkSupply and Erection of 11 kV G.O. Switch with 9 Nos. post insulator suitable heavy duty with suitable copper male and female contents for 11kV, G.I. pipe, nut and bolts complete as per ISS: 1816/1972 and ISS: 2544/1963 as per DHBVN specification with latest amendment thereof compete in all respect 6 Job WorkSupply and Erection of 11kV Lightning Arrester as per approved makes and relevant IS specifications of DHBVN. 7 Job WorkSupply and Erection of 11kV polymeric Pin insulator 10 kN with GI Pin of approved make / specification of DHBVN. 8 Job WorkSupply and Erection of ACSR conductor of size 50mm2 conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments as per DHBVN specification including stringing and sagging jointing and binding with insulator at supports in all respect upto the entire satisfaction of Engineer-in-charge. 9 Job WorkSupply and Erection of LT PVC unarmoured cable of size 300 Sqmm single core with aluminium conductor 650/1100 V conforming to ISS 1554 (Part-I) of 1988 IS: 7098/Part-1/ 1988 with latest amendments upto entire satisfaction of Engineer-in-charge(Make: Grandlay, Polycab, Havells, CIRTINA) 10 Job WorkSupplyand Erection of fuse unit of L.T. side suitable for 200 kVA transformer as per DHBVN specification complete with wooden board, aluminium bus bar MS clamps and MS nut and bolts including all petty material required up to the entire satisfaction of Engineer-in-charge 11 Job WorkSupply and erection of L.T. Aerial Bunched cable of size 120 Sqmm, 4 coreplus95 Sqmm messenger including making of necessary connection of make Polycab, Havell’s, Grandlay complete in all respect upto the entire satisfaction of Engineer-in-charge. 12 Job WorkSupply and Erection of wooden cleats of size 4” wide 1’-6” long complete with 4 Nos. holes suitable to pass through 300/400 Sqmm single core cable complete in all respect upto the entire satisfaction of Engineer-in-charge 13 Job WorkSupply and erection of Galvanized steel item (Flat, Angle, Channel) including cutting bending to the required shape drilling hole carriage loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. 14 Job WorkSupply and erection of Galvanized Nut and Bolts of various sizes carriage loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge . Last date of submission for this tender is 2025-10-01. This is a Transformer Supply tender in Hisar, Haryana

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

5 issued
  • Tender Document 1html
  • Tender Document 2pdf
  • Tender Document 3xlsx
  • Tender Document 4pdf
  • Tender Document 5pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in