🎉 Your free trial plan has started. Plan will expire in 0 days

Haryana Power Generation Corporation Limited

khedar, haryana

AOC value
₹37.41L
AOC date
5 Jan
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 5 Jan 24AOC date

Important info

Result ID
Refer Docs
Award of contract
05/01/2024
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Haryana Power Generation Corporation Limited has published Supply Of Cables , Cables , Cable Flexible, Type – Flat, Size - 4 Sq. Mm, Voltage Rating – 1100 V, Ambient Temperature - 10 To 70 Deg. Celsius, No Of Core – 3 Core, Conductor Type - Electrolytic Grade Annealed Flexible Bunched Bare Copper Conductor. Conductor Type – Multistrand, Conductor Material – Copper, Insulation Material - Flexible Pvc, Indian Standard -Is:694, Is 8130, Additional Information – Pvc Insulation Of Core, Pvc Sheath, Suitable For Borewell Submersible Pump, Color Coding Of Core - R, Y, B. , Festoon Cable, Size - 16C X 2.5 Sq.Mm, 1100V Grade, Flexible Type, Annealed Tinned Stranded Copper Conductor, Epr Insulated,Cores Laid Up Together & Overall Sheathed With Pcp, Generally Conforming To Is-9968/Part-I/88 Or Latest Amendment, If Any. , Screened Control Cable, Size 4P X 0.5 Sq. Mm, 1.1 Kv Grade, Stranded Copper Conductor, Annealed, Multi Core, Pvc Insulated, Extruded Pvc Inner Sheathed, Colour Coded, Twisted Pair Individually, Pairs Individually Screened & Overall Screened, Drain Wire To Be Provided Separately For Individual Pair Shield And Overall Shield, Galvanised Steel Strip / Wire Armoured And Pvc Outer Sheath Generally Confirming To Is-1554, Part-1 Or Latest Amendment. , Screened Control Cable, Size 2P X 1.5 Sq. Mm, 1.1 Kv Grade, Stranded Copper Conductor, Annealed, Multi Core, Pvc Insulated, Extruded Pvc Inner Sheathed, Colour Coded, Twisted Pair Individually, Pairs Individually Screened & Overall Screened, Drain Wire To Be Provided Separately For Individual Pair Shield And Overall Shield, Galvanised Steel Strip / Wire Armoured And Pvc Outer Sheath Generally Confirming To Is-1554, Part-1 Or Latest Amendment. , Control Cable, Size 7C X 2.5 Sq. Mm (Ywy), 1.1 Kv Grade, Stranded Copper Conductor, Pvc Insulated, Extruded Pvc Inner Sheathed, Galvanised Steel Wire Armoured And Extruded Pvc Overall Jacketed And Confirming To Is-1554, Part-1 Or Latest Amendment. , Control Cable, Size 19C X 2.5 Sq. Mm (Flexible), 1.1 Kv Grade, Annealed Tinned Stranded Copper Conductor, Epr Insulated, Pcp Inner Sheathed, Colour Coded, Cores Laid Up Together Suitably And Overall Pcp Sheathed Generally Confirming To Is-9968, Part-1 Or Latest Amendment, Class-5 Flexibility. , 3Cx70sq Mm Cable, 1.1Kv Grade Stranded Aluminium Conductor, Xlpe Insulated, Armoured, Confirming To Relevant Is Standard. , 3Cx240sq Mm Cable, 1.1Kv Grade Stranded Aluminium Conductor, Xlpe Insulated, Armoured, Confirming To Relevant Is Standard , 4Cx35sq Mm Cable, 1.1Kv Grade Stranded Aluminium Conductor, Xlpe Insulated, Armoured, Confirming To Relevant Is Standard , 2Cx16sq Mm Cable, 1.1Kv Grade Stranded Aluminium Conductor, Xlpe Insulated, Armoured, Confirming To Relevant Is Standard. , 3Cx10sq Mm Cable, 1.1Kv Grade Stranded Aluminium Conductor, Xlpe Insulated, Armoured, Confirming To Relevant Is Standard. , Power Cable: Specification/Voltage Grade: Pvc Armoured, 650/1100V: Conductor: Aluminium: Cable Section:3.5 Core X 16 Sq. Mm Testing Of Cable As Per Is:810/1554/694/5831/7098/8130 As Applicable , Power Cable: Specification/Voltage Grade:Pvc Armoured, 650/1100V : Conductor: Aluminium: Cable Section: 4 Corex400 Sq.Mm. Testing Of Cable As Per Is:810/1554/694/5831/7098/8130 As Per Applicable , Power Cable: Specification/Voltage Grade:Pvc Armoured Frls Type, Multi Strand, 650/1100V, Conductor: Aluminium:Cable Section: 3Core X 35 Sq. Mm. Testing Of Cable As Per Is:810/1554/694/5831/7098/8130 As Per Applicable , Power Cable: Specification/Voltage Grade Xlpe Insulated, Stranded Conductors, Armoured, Aluminium Cable, 3.5 Core X 150 Sq. Mm, 1.1Kv Frls Is 7098 Part-I/68. Testing Of Cable As Per Is:810/1554/694/5831/7098/8130 As Per Applicable , Power Cable: Specification/Voltage Grade Cable, 1.1Kv Grade Stranded Aluminium Conductor Armoured, Xlpe Insulated 3.5C X70 Sq.Mm. . Testing Of Cable As Per Is:810/1554/694/5831/7098/8130 As Per Applicable , Power Cable: Specificaiton/Voltage Grade Cable, 1.1Kv Grade Stranded Aluminium Conductor Armoured, Xlpe Insulated 3.5C X 240 Sq. Mm. Testing Of Cable As Per Is:810/1554/694/5831/7098/8130 As Per Applicable , Power Cable: Specification /Voltage Grade Cable, 1.1Kv Grade Stranded Copper Conductor Armoured, Pvc Insulated 2C X 2.5 Sq. Mm.Testing Of Cable As Per Is:810/1554/694/5831/7098/8130 As Per Applicable , Pendant Control Cable For Eot Crane,Specification / Voltage Grade: 650/1100 V Insulation-Inner & Outer Sheath Rubber,Unarmoured,Conductor-Multi Stranded Copper Conductor,Cable Section-12C/2.5 Sq.Mm,Testing-Is:1554-1988 (Part-I). Last date of submission for this tender is 2023-09-01. This is a Cranes tender in Khedar, Haryana

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

7 issued
  • Tender Document 1pdf
  • Tender Document 2pdf
  • Tender Document 3pdf
  • Tender Document 4pdf
  • Tender Document 5xlsx
  • Tender Document 6html
  • Tender Document 7pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in