🎉 Your free trial plan has started. Plan will expire in 0 days

Haryana Dairy Development Cooperative Federation Limited

panchkula, haryana

AOC value
₹13.57L
AOC date
22 May
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 22 May 25AOC date

Important info

Result ID
Refer Docs
Award of contract
22/05/2025
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Haryana Dairy Development Cooperative Federation Limited has published Supplying, Installing And Commissioning Of Inverter Air Conditioners For Variable Speed Compressor In The Office Of Hddcf, Hqrs., Panchkula Supplying, Installing And Commissioning Of Inverter Air Conditioners For Variable Speed Compressor In The Office Of Hddcf, Hqrs., Panchkula , Providing, Fixing, Installing And Commissioning Of 2 Ton With Minimum 3 Star Rating Of Bee Air Conditioners (Split Type) Inverter Air Conditioners For Variable Speed Compressor, Complete With Indoor Unit (Idu), Outdoor Unit (Odu), Surface/Concealed Copper Refrigerant Piping With Insulation (Ep Foam Pipe Section) Upto 3 Mtrs Idu To Odu), Copper Cable Upto 3 Mtr. (Idu To Odu), R-32/R-410 Refrigerant, Pvc Drain Pipe (Dia 15 Mm) Upto 3 Mtr., Remote, Odu Stand, With All Accessories Provided By Brand Manufacturer Complete In All Aspects. The Condensor Coil Shall Be Of Copper With Blue/Golden Fins. Warranty Given As Per Brand Manufacturer. **Mention The Make Of A.C. For Which The Rates Are Quoted In Annexure Ii Of Tender Document*8 , Providing, Fixing, Installing And Commissioning Of 1.5 Ton With Minimum 3 Star Rating Of Bee Air Conditioners (Split Type) Inverter Air Conditioners For Variable Speed Compressor, Complete With Indoor Unit (Idu), Outdoor Unit (Odu), Surface/Concealed Copper Refrigerant Piping With Insulation (Ep Foam Pipe Section) Upto 3 Mtrs Idu To Odu), Copper Cable Upto 3 Mtr. (Idu To Odu), R-32/R-410 Refrigerant, Pvc Drain Pipe (Dia 15 Mm) Upto 3 Mtr., Remote, Odu Stand, With All Accessories Provided By Brand Manufacturer Complete In All Aspects. The Condensor Coil Shall Be Of Copper With Blue/Golden Fins. Warranty Given As Per Brand Manufacturer. **Mention The Make Of A.C. For Which The Rates Are Quoted In Annexure Ii Of Tender Document** , Providing, Fixing, Installing And Commissioning Of 1.5 Ton With Minimum 3 Star Rating Of Bee Air Conditioners (Window Type) Of Inverter Air Conditioners For Variable Speed Compressor, Complete With Indoor Unit (Idu), Outdoor Unit (Odu), Copper Cable Upto 3 Mtr., R-32/R-410 Referigerant, Pvc Drain Pipe (Dia 15 Mm) Upto 3 Mtr., Remote, Complete In All Aspects. The Condensor Coil Shall Be Of Copper With Blue/Golden Fins. Warranty Given As Per Brand Manufacturer. **Mention The Make Of A.C. For Which The Rates Are Quoted In Annexure Ii Of Tender Document** , Providing, Fixing And Laying Extra Copper Referigerant Pipe With Insulation After 3 Mtr. (Idu To Odu) I) Discharge Pipe , Providing, Fixing And Laying Extra Copper Referigerant Pipe With Insulation After 3 Mtr. (Idu To Odu) Ii) Suction Pipe , Providing And Fixing Pvc Insulated 3 Core Single Phase Copper Cable Wire (3 X 2.5 Sq Mm) For After 3 Mtr. (Idu To Odu / Idu To Stabilizer). , Providing And Fixing 5 Kva Copper Winded Stabilizer With Working Range Of 90 V-300V Having Display Showing Input/Output Voltage With All Accessories. , Providing And Fixing 4 Kva Copper Winded Stabilizer With Working Range Of 90 V-300V Having Display Showing Input/Output Voltage With All Accessories. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. Hsr 23.7.6.2 I.) 25 Mm Dia , Hsr 23.7.6.3 Ii.) 32 Mm , Hsr 23.7.6.4 Iii.) 40 Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel / Pvc Conduit As Required.23.5.6.2 I.) 3 X 2.5 Sq. Mm , 23.5.6.3 Ii.) 3 X 4 Sq. Mm , 23.5.6.4 Iii.) 3 X 6 Sq. Mm , Supplying And Fixing Dp Sheet Steel Enclosure On Surface/ Recess Along With 32/40 Amps 240 Volts 10Ka C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required.. Last date of submission for this tender is 2025-05-15. This is a Air Conditioner tender in Panchkula, Haryana

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

2 issued
  • Tender Document 1html
  • Tender Document 2pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in