🎉 Your free trial plan has started. Plan will expire in 0 days

Department Of Agriculture

sonipat, haryana

AOC value
₹3.49Cr
AOC date
6 Jan
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 6 Jan 26AOC date

Important info

Result ID
Refer Docs
Award of contract
06/01/2026
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Department Of Agriculture has published Tender For Reclamation Of Water Logged And Saline Soil Throughsub-Surface Drainage Technology In The Villagegangana, Block-Mundlana And District-Sonipat (Ssdblock Jd-18 To Jd-23) (Revise - NS Item -1200 mm dia RCC Pipe with bottom plugged, of length of 2.5 meter, conforming IS: 458-2021, Base Plate monolithic, Steel welded with reinforcement(inside inbuilt steel steps) cement M-35 plus Grade mortar ,Base plate and steps as per specification provided in drawing 3 NS Item -1200 mm dia RCC Pipe without bottom plugged, of length of 2.5 meter, conforming IS: 458-2021, Base Plate monolithic, Steel welded with reinforcement(inside inbuilt steel steps) cement M-35 plus Grade mortar ,Base plate and steps as per specification provided in drawing 4 NS Item -900 mm dia RCC Pipe with bottom plugged, of length of 2.5 meter, conforming IS: 458-2021, Base Plate monolithic, Steel welded with reinforcement(inside inbuilt steel steps) cement M-35 plus Grade mortar ,Base plate and steps as per specification provided in drawing 5 NS Item -900 mm dia RCC Pipe without bottom plugged, of length of 1.25 meter, conforming IS: 458-2021, Base Plate monolithic, Steel welded with reinforcement(inside inbuilt steel steps) cement M-35 plus Grade mortar ,Base plate and steps as per specification provided in drawing 6 NS Item -Corrugated PVC Pipes 80mm. Specifications as per IS-9271:2004 standard duly ISI marked The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS9271:2004.Estimated weight 340 g/m 7 NS Item -End Caps for Corrugated PVC Pipes 72/80mm Specifications as per IS-9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004 8 NS Item -Couplers for Corrugated PVC Pipes 72/80mm Specifications as per IS-9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. 9 NS Item -Plastic Thread for Wrapping of filter around 80mm dia lateral pipes 10 NS Item -Wrapping the filter around the lateral pipe 11 NS Item -Filter Material for 80mm outer dia lateral pipe Specifications – the material should be non woven polypropylene, minimum thickness shall be 2.6mm confirming to thickness test prescribed in IS 13162(part5) at 1992, mass per unit area will be 300g/mm2, the strip width shall be 31cm ,the O90 apparent opening size may vary from 350-500 microns 12 NS Item -Saddle Bend 80mmX 294 mm for Perforated Corrugated PVC Pipes 258 mm id/294 mm outer dia Specifications as per IS9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. ( Without GST) 13 NS Item -Saddle Tee (Combined) 80mmX 80mmX294mm for Perforated Corrugated PVC Pipes 258 mm id/294 mm outer dia Specifications as per IS:9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. ( Without GST) 14 NS Item -Saddle Tee (Combined) 80mmX 80mmX200mm for Perforated Corrugated PVC Pipes 178 mm id/200 mm outer dia Specifications as per IS:9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. ( Without GST) 15 NS Item -Saddle Tee Combined 80mmX 160 mm for Perforated Corrugated PVC Pipes 144 mm id/160 mm outer dia Specifications as per IS:9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. ( Without GST) 16 NS Item -Couplers( Jointer) 294 mm for Perforated Corrugated PVC Pipes 258 mm id/294 mm outer dia Specifications as per IS9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. Estimated weight 2500 gm/m( Without GST) 17 NS Item -Couplers( Jointer) 200 mm for Perforated Corrugated PVC Pipes 178 mm id/200mm outer dia Specifications as per IS9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. Estimated weight 1690 gm/m( Without GST) 18 NS Item -Couplers( Jointer) 160mm for Perforated Corrugated PVC Pipes 144id/160 outer dia mm Specifications as per IS9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. Estimated weight 1140 gm/m( Without GST) 19 NS Item -Perforated Corrugated PVC Pipes 144id/160 od mm Specifications as per IS-9271:2004 standard duly ISI marked The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS:9271:2004.Estimated weight 1140gm/m( Without GST) 20 NS Item -Perforated Corrugated PVC Pipes 178id/200od mm Specifications as per IS-9271:2004 standard duly ISI marked The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004.Estimated weight 1690 gm/m( Without GST) 21 NS Item -Nylon Socks for Perforated Corrugated PVC Pipes 294 mm outer dia. Material is woven synthetic nylon, maximum thickness is 1mm, maximum pore size 60 micron mesh. the strip width should be 550 and should be sufficient to cover outer dia with minimum overlap 25% 22 NS Item - Nylon Socks for Perforated Corrugated PVC Pipes 200 mm outer dia. Material is woven synthetic nylon, maximum thickness is 1mm, maximum pore size 60 micron mesh. the strip width should be 550 and should be sufficient to cover outer dia with minimum overlap 25% 23 NS Item -Nylon Socks for Perforated Corrugated PVC Pipes 160 mm outer dia. Material is woven synthetic nylon, maximum thickness is 1mm, maximum pore size 60 micron mesh. the strip width should be 550 and should be sufficient to cover outer dia with minimum overlap 25% 24 NS Item -Wrapping, pulling the nylon sock over the collector pipe for SSD Work 25 NS Item -Perforated Corrugated PVC Pipes 258/294mm Specifications as per IS:9271-2004 standard duly ISI marked The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004.Estimated weight 2500 gm/m( Without GST) 26 NS Item -Labour for staking, joints,cutting of pipe,changing of boom, following of trencher, connection of pipe to the mainholes, sump, carriage of pipes for manholes, unloading of pvc pipe etc 27 NS Item -Saddle Bend 80mmX 160 mm for Perforated Corrugated PVC Pipes 144 mm id/160 mm outer dia Specifications as per IS9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. ( Without GST) 28 NS Item -Saddle Bend 80mmX 200 mm for Perforated Corrugated PVC Pipes 178 mm id/200 mm outer dia Specifications as per IS9271:2004 standard duly ISI marked. The samples would also be exposed to acetone test as per clause 5:3:4 of ASTM F-800 in addition to physical test mentioned in IS-9271:2004. ( Without GST) 29 NS Item -Control Panel Steel Box with lock Size 0.60 mtr x 0.50m x0.45 mtr of 6 mm G.I metal 30 NS Item -Painting and Writing Name of SSD Blocks on Iron Doors of Fencing 31 NS Item -Flange for pvc pipe 32 NS Item -Nipple for 100mm PVC pipe length 15 cm 33 NS Item -Rubber Jain Thickness not less than 3mm 34 NS Item -3 HP DC Surface Solar Photovoltaic Water Pumping System (SPWPS). As per HAREDA Guidelines 35 NS Item - Installation cost of manhole RCC pipes 900mm dia (2 pieces of length 2.5m and 1.25m ) Vertically as per specification given in design 36 NS Item -Installation cost of sump RCC pipes 1200mm dia (2 pieces of length 2.5 each) Vertically as per specification given in design n 37 NS Item -Installation/ Laying of Perforated Corrugated PVC Pipes 80mm outer dia Lateral pipe in given slope as per specifications given in design at depth varying from 4 feet to 10 feet n 38 NS Item - Installation/ Laying of Perforated Corrugated PVC Pipes 294mm outer dia Collector pipe in given slope as per specifications given in design at depth varying from 6 feet to 10 feet n 39 NS Item -Installation/ Laying of Perforated Corrugated PVC Pipes 200mm outer dia Collector pipe in given slope as per specifications given in design at depth varying from 6 feet to 10 feet n 40 NS Item -Installation/ Laying of Perforated Corrugated PVC Pipes 160mm outer dia Collector pipe in given slope as per specifications given in design at depth varying from 6 feet to 10 feet n 41 NS Item -Nylon Socks for Perforated Corrugated PVC Pipes 160 mm outer dia. Material is woven synthetic nylon, maximum thickness is 1mm, maximum pore size 60 micron mesh. the strip width should be 550 and should be sufficient to cover outer dia with minimum overlap 25% . Last date of submission for this tender is 2025-10-31. This is a Drainage tender in Sonipat, Haryana

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

5 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
  • Tender Document 5pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in