Ministry Of Petroleum And Natural Gas
- AOC value
- ₹40.31L
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Ministry Of Petroleum And Natural Gas has published Bids Are invited for Supply, Installation testing & commissioning of analysers for CAAQMS-4 for OPaL Dahej. 0C4100970063 ANLYSR,SOX, CAAQMS,0- 500PPB ANALYSERS; TYPE, ANALYSER:SOX,CAAQMS; RANGE:0 TO 500 PPB; POWER SUPPLY:230V AC;APPROVALS:USEPA; PRINCIPLE OF MEASUREMENT:UV FLUORESCENCE; LOWER DETECTABLELIMIT:1 PPB; NOISE LEVEL:0.5 PPB; ZERO DRIFT<1 PPB/24 HRS; SPAN DRIFT<2% IN 15DAYS OF FULL SCALE; LINEARITY:+/- 1% OF FULL SCALE; RESPONSE TIME:120 SEC ORLESS; CALIBRATION MUST BE DONE THROUGH MUTI POINT MULTI GAS CALIBRATION SYSTEM;ANALOG OUTPUT:4 TO 20 MA; DIGITAL OUTPUT:ETHERNET; SOX MEASUREMENT IN AMBIENTAIR; RACK:19 IN 1 EA 2 0C4100970064 ANLYSR,NOX, CAAQMS,0- 1000PPB ANALYSERS; TYPE, ANALYSER:NOX,CAAQMS; RANGE:0 TO 1000 PPB; POWER SUPPLY:230 VAC; APPROVAL:USEPA; PRINCIPLE OF MEASUREMENT:CHEMILUMINESCENCE;MEASUREMENT:NO-NO2- NOX IN AMBIENT AIR; LOWER DETECTABLE LIMIT:1 PPB; NOISELEVEL:0.5 PPB; ZERO DRIFT:< 1 PPB/24 HRS; SPAN DRIFT:< 2% IN 15 DAYS OF FULLSCALE; LINEARITY:± 1% OF FULL SCALE; RESPONSE TIME:120 SEC OR LESS; CALIBRATIONMUST BE DONE THROUGH MUTI POINT MULTI GAS CALIBRATION SYSTEM; ANALOG OUTPUT:4 TO20 MA; DIGITAL OUTPUT:ETHERNET; RACK:19 IN 1 EA 3 0C4100970065 ANLYSR,THC, CAAQMS,0- 200PPM ANALYSERS; TYPE, ANALYSER:TOTAL HYDROCARDON,CAAQMS; RANGE:0 TO 200 PPM; POWERSUPPLY:230 VAC; PRINCIPLE OF MEASUREMENT:FLAME IONIZATIONDETECTION; RACK:19 IN; MEASUREMENT:METHANE AND NON-METHANE HYDROCARBONS INAMBIENT AIR; REPEATABILITY:+/- 1 % FULL SCALE; DRIFT:+/- 1 % OF FULL SCALE (24HOURS); RESPONSE TIME:T90<30 SECONDS; CALIBRATION MUST BE DONE THROUGH MUTIPOINT MULTI GAS CALIBRATION SYSTEM; ANALOG OUTPUT:4 TO 20 MA; DIGITALOUTPUT:ETHERNET 1 EA 4 0C4100970066 ANLYSR,PM2.5 ,CAAQMS,0– 1000 MICRO-G/M3 ANALYSERS; TYPE, ANALYSER:PM2.5,CAAQMS; RANGE:0 TO 1000 MICRO-G/M3; POWERSUPPLY:230 VAC; APPROVAL:USEPA; PRINCIPLE OF MEASUREMENT:BETA-RAY ATTENUATION;PARTICLE SIZE CUT OFF:0 TO 2.5 MICRONS; RESOLUTION:1% OF THE MEASUREMENT RANGE;LOWER DETECTION LIMIT:< 4.8 MICRO G/M3 (1 HOUR); ROLL LENGTH:MINIMUM 20 METERS;DIGITAL OUTPUT:ETHERNET; ANALOG OUTPUT:4 TO 20 MA; RACK:19 IN 1 EA 5 0C4100970067 ANLYSR,PM10, CAAQMS,0- 1000 MICRO G/M3 ANALYSERS; TYPE, ANALYSER:PM10,CAAQMS; RANGE:0 TO 1000 MICRO G/M3; POWERSUPPLY:230 VAC; APPROVAL:USEPA; PRINCIPLE OF MEASUREMENT:BETA-RAY ATTENUATION;RACK:19 INCH; PARTICLE SIZE CUT OFF:0-10 MICRONS; RESOLUTION:1% OF THEMEASUREMENT RANGE; LOWER DETECTION LIMIT:< 4.8 MICRO G/M3 (1 HOUR); ROLLLENGTH:MINIMUM 20 METERS; DIGITAL OUTPUT: ETHERNET; ANALOG OUTPUT:4 TO 20 MA 1 EA 6 0C4100970068 ANLYSR,MULTI CALIBRATOR, 19IN,0.45MPA ANALYSERS; TYPE, ANALYSER:MULTI POINT CALIBRATOR; MULTIPOINT CALIBRATOR WITHZERO GAS GENERATOR; POWER SUPPLY:230 VAC; RACK:19 IN; ZERO AIRGAS AIR GENERATOR:0-10 L/MIN; ZERO AIR PRESSURE:MAXIMUM OUTPUT PRESSURE 0.45MPA; (I); MULTIPOINT CALIBRATION USING AUTOMATIC DILUTION SYSTEM FOR THECALIBRATION OF SOX, NOX, THC ANALYZER; AUTO CALIBRATION FACILITY REQUIRED;CALIBRATOR TO DAS COMPATIBLE Total Quantity : 7. Last date of submission for this tender is 2025-08-28. This is a Industrial Gases tender in Bharuch, Gujarat
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
1 issued- Tender Document 1htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free