🎉 Your free trial plan has started. Plan will expire in 0 days

Military Engineer Services

bhuj, gujarat

AOC value
₹4.85L
AOC date
2 Jan
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 2 Jan 26AOC date

Important info

Result ID
Refer Docs
Award of contract
02/01/2026
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Military Engineer Services has published Tender For Provision Of Work Services For I Level Facility Redicom Of Sudarsan System At Af Station Bhuj; 1 Material & labour for shifting of transformer/ voltage stabilizer upto 200 KVA capacity from one location to other location of any capacity including removing the existing HT/LT/removing and refixing of connectors mounted on wall connection of any type transformer and transporting the same to desired location within airforce stn bhuj. The same installing connecting HT/LT cables, earthing testing and commissioningcomplete all as specified and directed by Engineer-in-Charge. 2 Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 240 sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. 3 Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 50 sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. 4 Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 16 sqmm, 4.0 core complete all as specified and directed by Engineer-in-Charge. 5 Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge. 6 Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge. 7 Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and directed by Engineer-in-Charge. 8 Material & labour for sand cushioning for UG cables using dry river sand; gently punning down complete all as specified and directed by Engineer-in-Charge.( Note : For measurement purpose punned thickness shall be considered) 9 Supply & lay ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV, flate size 300mm X 180 mm X 40 mm in trenches as protection to LT UG cable complete all as specified and directed by Engineer-in-Charge. 10 Material & labour for heat shrinkable indoor/ outdoorLT end terminations for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing etc of cable size 35 to 240 Sqmm, 3.5 core complete all as specified and as directed by Eng-in-Charge. 11 Supply & fix fabricating LT panel indoor type, dust and vermin proof totally enclosed with sloping canopy fabricated out of steel section the door opening shall not be less than 150 degree. The construction of panel board shall be dust vermin proof IP 54 standard double shutter gears front and rear frame work and 3.15 mm thick MS sheet duly painted with powder coated over two coats of red oxide primer and madeof 40x40x6 mm thick angle iron frame all as specified suitable for 415 volts 50 Hz 3 phase and neutral system and shall be complete with 400 Amps capacity copper bus bar with bus bar chamber internal wiring with suitable size of PVC insulated copper cable lugs comprising of following accessories-:IncomingMCCB 4 pole 350 Amps 36 KA-01 Nos OUTGOING(i) MCCB 4 pole 200 Amps 36 KA-02 Nos(ii) MCCB 100 Amps 16 KA 4 pole-03 NosDigital type Ammeter with CT 0-400-01 NoDigital type Voltmeter 0-500-01 NoIndicator-RYB 12 Supply & fixindustrial plug and socket 3P+E+N, 415 volt, 16 Amps rating code No DHDPBTN016 complete all as specified and directed by Engineer-in-charge. 13 Supply & fix in replacement FRP juction box of size outside dimensions 400 x 300 x 190 mm with 4 nos copper busbar of capacity 100 Amps , length 250 mm ,01 No MCCB of 100 Amps capacity inside the boxas approved by the Engineer-in-Charge including connectorand fixing on pole/wall with and including MS clamps made out of 25 x 3mm MS flat iron, nut, bolts etc complete all as specified and directed by Engineer-in-ChargeNote:- The cost of sintex box installation includes making hole of suitable size for entry and exist of cable any size, making new lugs of cables of entry and exit including cable glands. 14 Supply & fix copper strip 32 x 6 mm with saddles and fixing screws etc.for jointing with earth pits complete all as specified and directed by Engineer-in-charge . Last date of submission for this tender is 2025-12-20. This is a Transformer Supply tender in Bhuj, Gujarat

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

7 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
  • Tender Document 7pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in