🎉 Your free trial plan has started. Plan will expire in 0 days

Health And Family Welfare Department

vadodara, gujarat

AOC value
₹4.05L
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Health And Family Welfare Department has published Bids Are Invited For Knee Re-Alignment Plate-1 -- 1 Low Profile Anatomic Titanium Ti-6Al-4V-Eli Material4 Hole T Oblique Knee Re-Alignment Plate Which Should Accommodate Titanium Spacer Size 8Mmor10or12mm And 14Mm And Should Have Placement Jig And Chiselfree Spacer Or Sizer In The Instrument Set 2 Low Profiletitanium Ti-6Al-4V-Eli Material 5Mm Locking Head Screw 22Mm To 50Mm In 2Mm Increment Compatible With 4 Hole Anatomic T Oblique Knee Re-Alignment Plate Which Should Accommodate Titanium Spacer Size 8Mmor10or12mm 3 Low Profile Anatomic Titanium Ti-6Al-4V-Eli Material Locking Head Screw 50Mm To 80Mm In 5Mm Increment Compatible With 4 Hole Anatomic T Oblique Knee Re-Alignment Plate Which Should Accommodate Titanium Spacer Size 8Mmor10or12mm And 14Mm 4 Low Profiletitanium Ti-6Al-4V-Eli Material 5Mm Cancellous Locking Head Screw 30Mm To 70Mm In 5Mm Increment Compatible With 4 Hole Anatomic T Oblique Knee Re-Alignment Plate Which Should Accommodate Titanium Spacer Size 8Mmor10or12mm 5 Low Profiletitanium Ti-6Al-4V-Eli Material 4.5Mm Cortical Screw 20Mm To 50Mm In 2Mm Increment Compatible With 4 Hole Anatomic T Oblique Knee Re-Alignment Plate Which Should Accommodate Titanium Spacer Size 8Mmor10or12mm 6 Low Profiletitanium Ti-6Al-4V-Eli Material 5Degree 8Mm Wedge With 4 Hole Anatomic T Oblique Knee Re-Alignment Plate 7 Low Profiletitanium Ti-6Al-4V-Eli Material5degree 10Mm Wedge With 4 Hole Anatomic T Oblique Knee Re-Alignment Plate 8 Low Profiletitanium Ti-6Al-4V-Eli Material 5Degree 12Mm Wedge With 4 Hole Anatomic T Oblique Knee Re-Alignment Plate 9 Low Profiletitanium Ti-6Al-4V-Eli Material5degree 14Mm Wedge With 4 Hole Anatomic T Oblique Knee Re-Alignment Plate 10 Low Profile Anatomic Variable Angel Knee Realignment Plate Guide With 8 To 30Degrees Of Adjustment And With Adjustment Drivermade From Ss420 Materialcompatible With 4 Hole T Oblique Knee Re-Alignment Plate Which Should Accommodate Titanium Spacer Size 8Mmor10or12mm And 14Mm And Should Have Placement Jig And Chiselfree Spacer Or Sizer In The Instrument Set. Last date of submission for this tender is 2022-12-08. This is a Screws tender in Vadodara, Gujarat

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in