🎉 Your free trial plan has started. Plan will expire in 0 days

Health And Family Welfare Department

vadodara, gujarat

AOC value
₹9.2L
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Health And Family Welfare Department has published Bids Are Invited For Implant-1 3.5 Mm Cortex Screws 12 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium..Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-2 3.5 Mm Cortex Screws 16 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-3 3.5 Mm Cortex Screws 18 Mm 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium..Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-4 3.5 Mm Cortex Screws 22 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-5 3.5 Mm Cortex Screws 24 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-6 3.5 Mm Cortex Screws 26 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-7 3.5 Mm Cortex Screws 28 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-8 3.5 Mm Cortex Screws 30 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium..Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-9 3.5 Mm Cortex Screws 32 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium..Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-10 3.5 Mm Cortex Screws 34 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-11 3.5 Mm Cortex Screws 36 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-12 3.5 Mm Cortex Screws 38 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-13 3.5 Mm Cortex Screws 40 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium..Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-14 3.5 Mm Cortex Screws 42 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-15 3.5 Mm Cortex Screws 46 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium..Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-16 3.5 Mm Cortex Screws 48 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-17 4.0 Mm Cancellous Locking Head Screws Size 35 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Havesmaller Core Dia To Increase Bone Purchase Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-18 4.0 Mm Cancellous Locking Head Screws Size 40 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Havesmaller Core Dia To Increase Bone Purchase Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-19 4.0 Mm Cancellous Locking Head Screws Size 45 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Havesmaller Core Dia To Increase Bone Purchase Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-20 4.0 Mm Cancellous Locking Head Screws Size 50 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Havesmaller Core Dia To Increase Bone Purchase Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-21 4.0 Mm Cancellous Locking Head Screws Size 60 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Havesmaller Core Dia To Increase Bone Purchase Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-22 4.0 Mm Cancellous Locking Head Screws Size 65 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Havesmaller Core Dia To Increase Bone Purchase Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-23 2.7 Mm Cortex Screws 14 Mm. Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-24 2.7 Mm Cortex Screws 16 Mm.Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-25 2.7 Mm Cortex Screws 18 Mm.Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium..Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-26 2.7 Mm Cortex Screws 20 Mm.Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium..Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-27 2.7 Mm Cortex Screws 32 Mm.Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium..Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-28 2.7 Mm Cortex Screws 34 Mm.Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium..Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-29 2.7 Mm L.H.S Screws 14 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-30 2.7 Mm L.H.S Screws 16 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-31 2.7 Mm L.H.S Screws 18 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-32 2.7 Mm L.H.S Screws 20 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-33 2.7 Mm L.H.S Screws 30 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-34 2.7 Mm L.H.S Screws 32 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-35 2.7 Mm L.H.S Screws 34 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-36 2.7 Mm L.H.S Screws 36 Mm Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-37 4.5 Mm Cortex Screws 28 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-38 4.5 Mm Cortex Screws 30 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-39 4.5 Mm Cortex Screws 32 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-40 4.5 Mm Cortex Screws 34 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-41 4.5 Mm Cortex Screws 60 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-42 4.5 Mm Cortex Screws 65 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-43 4.5 Mm Cortex Screws 70 Mm. 3.5 Mm Cortex Screw Must Be Self Tapping Screw Design Have Capability To Create Axial Compression It Must Eliminate Shear Forces Which Leads To Loss Of Reduction While Compressing A Plate To The Bone. Product Must Be Usfda Approved Made Up Of Medical Grade Titanium. Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body Implant-44 5 Mm Ao Type Locking Head Screws 26 Mm.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-45 5 Mm Ao Type Locking Head Screws 28 Mm.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-46 5 Mm Ao Type Locking Head Screws 30 Mm.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-47 5 Mm Ao Type Locking Head Screws 32 Mm.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-48 5 Mm Ao Type Locking Head Screws 34 Mm.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-49 5 Mm Ao Type Locking Head Screws 36 Mm.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-50 5 Mm Ao Type Locking Head Screws 38 Mm.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-51 5 Mm Ao Type Locking Head Screws 44 Mm.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-52 5 Mm Ao Type Locking Head Screws 46 Mm.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-53 5 Mm Ao Type Locking Head Screws 65 Mm.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-54 5 Mm Ao Type Locking Head Screws 70 Mm.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-55 5 Mm Ao Type Locking Head Screws 75 Mm.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-56 5 Mm Ao Type Locking Head Screws 85 Mm.5 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Larger Core Dia To Increase Strength Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute. Made Up Of Medical Grade Titanium. Product Must Be Usfda Approved Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-57 5.0 Mm Cancellous Lhs 55 Mm.5.0 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Smaller Core Dia To Increase Bone Purchase Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute With Cancellous Thred.Product Must Be Usfda Approved Made Up Of Medical Grade Titanium.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-58 5.0 Mm Cancellous Lhs 60 Mm.5.0 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Smaller Core Dia To Increase Bone Purchase Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute With Cancellous Thred.Product Must Be Usfda Approved Made Up Of Medical Grade Titanium.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-59 5.0 Mm Cancellous Lhs 65 Mm.5.0 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Smaller Core Dia To Increase Bone Purchase Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute With Cancellous Thred.Product Must Be Usfda Approved Made Up Of Medical Grade Titanium.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-60 5.0 Mm Cancellous Lhs 70 Mm.5.0 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Smaller Core Dia To Increase Bone Purchase Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute With Cancellous Thred.Product Must Be Usfda Approved Made Up Of Medical Grade Titanium.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-61 5.0 Mm Cancellous Lhs 75 Mm.5.0 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Smaller Core Dia To Increase Bone Purchase Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute With Cancellous Thred.Product Must Be Usfda Approved Made Up Of Medical Grade Titanium.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-62 5.0 Mm Cancellous Lhs 80 Mm.5.0 Mm L.H.S Must Have Conical Shaped Head Which Facilitates Alignment Of Screw In To Locking Plate To Provide Secure Screw Plate Construct. Must Have Smaller Core Dia To Increase Bone Purchase Have Hexagonal Recess Of Locking Head Must Have Self Tapping Flute With Cancellous Thred.Product Must Be Usfda Approved Made Up Of Medical Grade Titanium.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-63 4.0 Mm Cannulated Cancellous Screw 30 Mm Cannulated Shaft Accept 1.25 Mm Diameter Guidewire Hemispherical Head Ensures Optimal Annular Contact With Washer. Standard 2.5 Mm Hex Drive Seif Drilling Self Tapping Screw Tip Cancellous Thread Profile Uses Deep Cutting Threads With Large Pitch To Increase Resistance To Pull Out Must Be Made Up Of Medical Grade Titanium Also Have Reverse Cutting Thread.Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-64 4.0 Mm Cannulated Cancellous Screw 35 Mm Cannulated Shaft Accept 1.25 Mm Diameter Guidewire Hemispherical Head Ensures Optimal Annular Contact With Washer. Standard 2.5 Mm Hex Drive Seif Drilling Self Tapping Screw Tip Cancellous Thread Profile Uses Deep Cutting Threads With Large Pitch To Increase Resistance To Pull Out Must Be Made Up Of Medical Grade Titanium Also Have Reverse Cutting Thread.Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-65 4.0 Mm Cannulated Cancellous Screw 40 Mm Cannulated Shaft Accept 1.25 Mm Diameter Guidewire Hemispherical Head Ensures Optimal Annular Contact With Washer. Standard 2.5 Mm Hex Drive Seif Drilling Self Tapping Screw Tip Cancellous Thread Profile Uses Deep Cutting Threads With Large Pitch To Increase Resistance To Pull Out Must Be Made Up Of Medical Grade Titanium Also Have Reverse Cutting Thread.Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-66 4.0 Mm Cannulated Cancellous Screw 45 Mm Cannulated Shaft Accept 1.25 Mm Diameter Guidewire Hemispherical Head Ensures Optimal Annular Contact With Washer.Standard 2.5 Mm Hex Drive Self Drilling Self Tapping Screw Tip Cancellous Thread Profile Uses Deep Cutting Threads With Large Pitch To Increase Resistance To Pull Out Must Be Made Up Of Medical Grade Titanium Also Have Reverse Cutting Thread.Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-67 4.0 Mm Cannulated Cancellous Screw 55 Mm Cannulated Shaft Accept 1.25 Mm Diameter Guidewire Hemispherical Head Ensures Optimal Annular Contact With Washer.Standard 2.5 Mm Hex Drive Self Drilling Self Tapping Screw Tip Cancellous Thread Profile Uses Deep Cutting Threads With Large Pitch To Increase Resistance To Pull Out Must Be Made Up Of Medical Grade Titanium Also Have Reverse Cutting Thread.Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-68 4.0 Mm Cannulated Cancellous Screw 60 Mm Cannulated Shaft Accept 1.25 Mm Diameter Guidewire Hemispherical Head Ensures Optimal Annular Contact With Washer.Standard 2.5 Mm Hex Drive Self Drilling Self Tapping Screw Tip Cancellous Thread Profile Uses Deep Cutting Threads With Large Pitch To Increase Resistance To Pull Out Must Be Made Up Of Medical Grade Titanium Also Have Reverse Cutting Thread.Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-69 4.0 Mm Cannulated Cancellous Screw 65 Mm Cannulated Shaft Accept 1.25 Mm Diameter Guidewire Hemispherical Head Ensures Optimal Annular Contact With Washer.Standard 2.5 Mm Hex Drive Self Drilling Self Tapping Screw Tip Cancellous Thread Profile Uses Deep Cutting Threads With Large Pitch To Increase Resistance To Pull Out Must Be Made Up Of Medical Grade Titanium Also Have Reverse Cutting Thread.Product Must Be Usfda Approved .Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-70 4.0 Mm Cannulated Cancellous Screw 70 Mm Cannulated Shaft Accept 1.25 Mm Diameter Guidewire Hemispherical Head Ensures Optimal Annular Contact With Washer.Standard 2.5 Mm Hex Drive Self Drilling Self Tapping Screw Tip Cancellous Thread Profile Uses Deep Cutting Threads With Large Pitch To Increase Resistance To Pull Out Must Be Made Up Of Medical Grade Titanium Also Have Reverse Cutting Thread.Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-71 4.0 Mm Cannulated Cancellous Screw 75 Mm Cannulated Shaft Accept 1.25 Mm Diameter Guidewire Hemispherical Head Ensures Optimal Annular Contact With Washer.Standard 2.5 Mm Hex Drive Self Drilling Self Tapping Screw Tip Cancellous Thread Profile Uses Deep Cutting Threads With Large Pitch To Increase Resistance To Pull Out Must Be Made Up Of Medical Grade Titanium Also Have Reverse Cutting Thread.Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-72 4.0 Mm Cannulated Cancellous Screw 80 Mm Cannulated Shaft Accept 1.25 Mm Diameter Guidewire Hemispherical Head Ensures Optimal Annular Contact With Washer.Standard 2.5 Mm Hex Drive Self Drilling Self Tapping Screw Tip Cancellous Thread Profile Uses Deep Cutting Threads With Large Pitch To Increase Resistance To Pull Out Must Be Made Up Of Medical Grade Titanium Also Have Reverse Cutting Thread.Product Must Be Usfda Approved.Must Be Compatible With Existing System.Supplier Must Be Iso Certified Manufecturer Must Have Zed Certificate And Ce Certificate By Notified Body. Implant-73 Quick Bone Healing And Quick Setting Calcium Hydroxyapatite Injectable Cement Sets In 1020 Minutes.This Cement Acts As Osteoinductive Material And Promotes Bone Healing It Helps In Conduction Of New Bone Formation.This Cement Include With Dish Syringe Spatula And 14 Gauge Needle Provided With In The Packet Size 5 Gram Implant-74 Quick Bone Healing And Quick Setting Calcium Hydroxyapatite Injectable Cement Sets In 1020 Minutes.This Cement Acts As Osteoinductive Material And Promotes Bone Healing It Helps In Conduction Of New Bone Formation.This Cement Include With Dish Syringe Spatula And 14 Gauge Needle Provided With In The Packet Size 10 Gram Total Quantity : 2523. Last date of submission for this tender is 2022-09-06. This is a Kitchen Equipment tender in Vadodara, Gujarat

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in