🎉 Your free trial plan has started. Plan will expire in 0 days

National Centre For Antarctic And Ocean Research

Safety And Security Equipment
goa, goa
AOC Value₹1.48 Cr
AOC Date25 Mar 2026
Completion DaysRefer Docs
Bid AmountRefer Docs

Important Info

Result ID
Refer Docs
Award of Contract
25/03/2026
Authority
National Centre For Antarctic And Ocean Research
Published Date
Refer Docs
Tender Closing Date
Refer Docs
Tender No
55(00)/2025-2026/XXX/5XX
Bidding URL
https://www.exampletenders.gov.in/bid/98765
Tender
View Tender
Bidder Details
Bidder Name: Mr. Jhon Doe, Ranking 2

AOC Description

National Centre For Antarctic And Ocean Research has published Tender For Fire Alarm And Suppression System At Ncpor.; 1 SITC of Fire Alarm and Suppression system. 2 Main Panel : Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 + 5% V, 50 hz), 48 hrs. back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications and as instructed by engineer-in-charge: Two Loop Panel. 3 Loop cards : Supplying, installation, testing and commissioning of Loop cards of 04 loops for above two panels to be installed for Cryosphere Bhavan and Admin building. 4 Repeater Panel : Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required and as instructed by engineer-in-charge. 5 Multi-Detector: Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required and as instructed by engineer-in-charge 6 Heat-Detector: Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required and as instructed by engineer-in-charge. 7 MCP : Supplying, installation, testing & commissioning of addressable manual call point and along with fault isolator complete with base as required and as instructed by engineer-in-charge. 8 Sounder: Supplying, installation, testing & commissioning of addressable horn cum strobe and along with fault isolator complete with base as required and as instructed by engineer-in-charge. 9 Control Module:Supplying, installation, testing & commissioning of addressable fire control module, for integration of gas based suppression panel with main FAS panel in case of fire incident and gas cylinder discharge, etc. complete as required and as instructed by engineer-in-charge. 10 Remote monitoring system : Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.It shall have facility to change the sensitivity of any detectors. The software shall have more than 2000 data points + min 20% extra data points for future expansion. 11 Cable : Supplying & laying of 2x1.5 sqmm fire alarm armored cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armoring & FRLS outer sheath complete as required and as instructed by engineer-in-charge. 12 Gas suppression system: Supply, Installation, Testing and Commissioning of panel tube based gas suppression system of 02 KG direct variant cleaning agent CA HFC 236 and heat-sensitive polymer tube is connected to an extinguishing agent container via a pressure release valve,including mounting stand& its mounting accessories, complete integration with main fire alarm system. The cylinder shall be made up with sheet metal thickness 1.6mm, external epoxy powder coating, including testing and commissioning , complete as required and as instructed by engineer-in-charge.(For LT/HT panels, Server racks) 13 DWC pipe:Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. Direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required and as instructed by engineer-in-charge: 63 mm dia (OD-63 mm & ID-51 mm nominal) 14 GI Pipe: Providing and fixing following size G.I pipes complete with G.I fittings including trenching and refiling, etc, external work: 80mm dia nominal bore. 15 DC SPD:SITC of Type 3 Surge Protection Device (SPD), two-pole with three terminals (Positive, Negative, and Earth), suitable for 30VAC/DC systems, conforming to IEC 61643. The SPD shall be DIN rail mountable, encapsulated MOV-based design with fire-resistant sheath material and LED status indication. It shall provide protection against switching surges, with a nominal discharge current (In) of 10 kA and a maximum discharge current (Imax) of 20 kA per pole (8/20 µs waveform). The device shall support a continuous operating voltage (Uc) of 30 V or higher and have a voltage protection level (Up) less than 51 V, including 6/8 way PVC/metal DB box near each Main & Repeater panels (Apprx qty 08 Nos), 10 sq mm, four core cable+ plus 10 sq.mm green colour cable for interconnection & earthing, including its connection, testing and any other item, accessories required to complete the work in totality and as per the instructions of the Engineer-Incharge. 16 AC SPD: SITC of Type 1+2 Surge Protection Device (SPD), two-pole (suitable for phase and neutral), rated for 230 VAC, conforming to IEC 61643. The SPD shall be DIN rail mountable, encapsulated MOV-based design with fire-resistant sheath material. It shall provide protection against both lightning and switching surges, with a nominal discharge current (In) of 30 kA, maximum discharge current (Imax) of 60 kA, and impulse current rating (Iimp) of 12.5 kA per pole (10/350 µs waveform). The device shall support a continuous operating voltage (Uc) of 255 V or higher and have a voltage protection level (Up) less than 1.5 kV, including 10 sq mm two core cable + plus 10 sq.mm green colour cable for interconnection & earthing, including its connection and testing and any other item, accessories required to complete the work in totality and as per the instructions of the Engineer-Incharge. 17 Electrical cable: Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 18 GI Box:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required: 3 Module (100mmX75mm) 19 Switch socket: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 20 Switch socket: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet 21 CAMC after expiry of warranty period of One (01) Year for Sl No: 1.01 - 1.10: Total yearly charges for Comprehensive AMC of Fire alarm system for all the component’s mentioned at sl no 1.01 to sl no: 1.10, after expiry of DLP/warranty period of 01 year.The CAMC includes all parts and its accessories, cable, etc. as a complete system.Note: A stable power supply will be provided through UPS to the panels, however, any damage to the installed components should also be covered in case of power surge due to lightning, voltage fluctuation or short circuit due to high voltage. 22 1st year charges. 23 2nd year charges. 24 3rd year charges. 25 4th year charges. 26 5th year charges. 27 CAMC for the existing newly commissioned Fire alarm & PA system installed at the Sagar Bhavan building at NCPOR: Total yearly charges for Comprehensive AMC of Fire alarm and PA system for all the component’s installed (Main Panel: 01 (Model: AVENAR 2000 PWM), Detectors: 65(BFC), 25(AFC), Response indicator:25 , MCP: 07, Sounder: 07, Hooter: 06, PA rack: 01, PA Amplifier: 02, PA Mixer: 01, Mic: 02, ceiling speaker: 42,wire, etc) at Sagar Bhavan building after the expiry of its warranty period since January 2027.The CAMC includes all parts and its accessories, including cable, etc. as a complete system.Note: A stable power supply will be provided through UPS to the panels, however, any damage to the installed components should also be covered in case of power surge due to lightning, voltage fluctuation or short circuit due to high voltage. Note: PA system Make: HONEYWELL and FAS Make: BOSCH are installed. 28 1st year charges. 29 2nd year charges. 30 3rd year charges. 31 4th year charges. 32 5th year charges. 33 CAMC for the existing newly commissioned Fire alarm & PA system installed at the Polar Bhavan building at NCPOR:Total yearly charges for Comprehensive AMC of Fire alarm and PA system for all the component’s installed (Main Panel: 01(Model: AVENAR 2000 PWM), Detectors: 544, Response indicator: 227, MCP: 20, Sounder: 20, Repeater Panel: 01, PA rack: 01, PA Amplifier: 04, PA Mixer: 01, Mic: 01, ceiling speaker: 214, surface speaker: 33, wire, etc) at Polar Bhavan building after the expiry of its warranty period since June 2026.The CAMC includes all parts and its accessories, including cable, etc. as a complete system.Note: A stable power supply will be provided through UPS to the panels, however, any damage to the installed components should also be covered in case of power surge due to lightning, voltage fluctuation or short circuit due to high voltage. Note: PA system Make: HONEYWELL and FAS Make: BOSCH are installed. 34 1st year charges. 35 2nd year charges. 36 3rd year charges. 37 4th year charges. 38 5th year charges. 39 CAMC for the existing fire alarm system installed at the Expedition Hub at NCPOR: Total yearly charges for Comprehensive AMC of Fire alarm system for all the component’s installed (Detector: 112, MCP: 10, Sounder: 10) at Expedition Hub building since day one of commissioning of new items and making the entire system fictional and till 05 years.The CAMC includes all parts and its accessories, cable, etc. as a complete system.Note: A stable power supply will be provided through UPS to the panels, however, any damage to the installed components should also be covered in case of power surge due to lightning, voltage fluctuation or short circuit due to high voltage. Note: Existing all other installed components are BOSCH make. 40 1st year charges. 41 2nd year charges. 42 3rd year charges. 43 4th year charges. 44 5th year charges. 45 CAMC for the existing fire alarm system installed at the Vision Bhavan buildings at NCPOR:Total yearly charges for Comprehensive AMC of Fire alarm system for all the component’s installed (Smoke Detector:81, Multi detector: 49, Beam detector: 03, Remote indicator: 11, MCP:14, Sounder: 10, Photo Luminescent exit signage: 12) at Vision Bhavanbuildings since day one of commissioning of new items and making the entire system functional and till 05 years.The CAMC includes all parts and its accessories, cable, etc. as a complete system.Note: A stable power supply will be provided through UPS to the panels, however, any damage to the installed components should also be covered in case of power surge due to lightning, voltage fluctuation or short circuit due to high voltage. Note: Existing all other installed components are BOSCH make. 46 1st year charges. 47 2nd year charges. 48 3rd year charges. 49 4th year charges. 50 5th year charges. . Last date of submission for this tender is 2025-11-24. This is a Fire Alarm Systems tender in Goa, Goa

Insurance Surety Bond

Fast, Reliable & Accepted for EMD/PBG

  • Zero BG Limit Impact
  • Accepted in All Tenders
  • Quick Online Quote

Tender Documents

  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
  • Tender Document 5pdf
  • Tender Document 6pdf
  • Tender Document 7pdf
lock-red

Unlock the Tender details for free

description-svgrepo

Bidder Details

Bidder NameTechnical BidFinancial BidAOCBid ValueRank
Sharma infra projects pvt ltd
₹1,24,50,000.00L1
Verma constructions ltd
₹1,31,00,000.00L2
Nair engineering works
₹1,38,75,000.00L3
Iyer industrial solutions
₹1,43,20,000.00L4
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in