🎉 Your free trial plan has started. Plan will expire in 0 days

Indian Institute Of Technology

goa, goa

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Indian Institute Of Technology has published Tender For Non-Comprehensive Amc Of Air Conditioners, Water Coolers And Water Dispensers At Iit Goa; 1 Servicing of existing installed AC units, i/c checking the units and accessories for functional tests, cleaning of filter units, tightening of loose joints (if any), oiling, greasing and any other minor repairing work etc. as reqd, as per std practice. 2 Split AC of 1.0/1.5/2.0 TR or equivalent capacity. 3 Casettee of 2.0-3.0 TR or equivalent capacity 4 Installation, testing and commissioning of AC units (indoor & outdoor) along with accessories issued by the client i/c handling charges complete etc. as per standard practice. 5 Split AC of 1.0/1.5/2.0 TR or equivalent capacity. 6 Casettee of 2.0-3.0 TR or equivalent capacity 7 Dismantling of existing installed AC units along with accessories and shifting them on another location with in the campus as reqd i/c handling charges complete, as per standard practice. 8 Split AC of 1.0/1.5/2.0 TR or equivalent capacity. 9 Casettee of 2.0-3.0 TR or equivalent capacity 10 Supply and fixing of Flare Nut complete as reqd, as per standard practice for the following types of ACs: 11 Split/Cassettee AC of 1.0/1.5/2.0 TR or equivalent capacity: cooling copper pipe 12 Split/Cassettee AC of 1.0/1.5/2.0 TR or equivalent capacity: condensing copper pipe 13 Replacement of existing burnout Compressor from the outdoor unit in installed position and fixing the new Compressor in the AC unit i/c pressure testing & gas charging i/c handling charges complete etc. as reqd, as per standard practice under buyback of old one. (Make: Toshiba/Mitsubishi Electric/Hitachi/GMCC/Copeland/Danfoss). 14 1.0 /1.5/2.0 TR or equivalent capacity Split Inverter AC- R 410 A/R32 15 Charging of refrigerant gas in AC units i/c flushing of gas, leakage detection, testing, replacement of filter brazing joints etc. as reqd, as per standard practice. 16 1 TR or equivalent capacity Split Inverter AC- R 410 A 17 1 TR or equivalent capacity Split Inverter AC- R 32 18 1.5 TR or equivalent capacity Split Inverter AC- R 410 A 19 1.5 TR or equivalent capacity Split Inverter AC- R 32 20 2.0 TR or equivalent capacity Split Inverter AC- R 410 A 21 2.0 TR or equivalent capacity Split Inverter AC- R 32 22 Top up of refrigerant gas in AC units i/c leakage detection, testing, replacement of filter brazing joints etc. as reqd, as per standard practice. 23 R-32 Refrigerant Gas 24 R-410A Refrigerant Gas 25 Pdg. & fixing of extra cooling & condensing copper pipe line along with round electric cable of stranded copper conductor, PVC insulated & PVC Sheathed as per IS for connections from outdoor unit to indoor unit/voltage stabilizer etc. as reqd, as per standard practice, suitable for following type of ACs: 26 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation. 27 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation. 28 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation. 29 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation. 30 Pdg. & fixing of extra drain pipe as reqd, as per standard practice, suitable for all type of ACs (Split/Casettee) as per tonnage capacity of the AC unit: 31 Pdg. & fixing of AC outdoor unit floor/wall stand as reqd, as per standard practice, suitable for following type of ACs: 32 Split AC of 1.0/1.5/2.0 TR or equivalent capacity. 33 Casettee of 2.0-3.0 TR or equivalent capacity 34 Replacement of existing faulty AC sensors with new sensor of same rating including removing, fixing, testing & commissioning etc. as reqd, as per standard practice, suitable for following types of ACs: 35 Split AC of 1.0/1.5/2.0 TR or equivalent capacity. 36 Casettee of 2.0-3.0 TR or equivalent capacity 37 Repairing (rewinding etc. complete) of existing faulty Condenser Cooling Fan Motor (AC/DC) including removing, fixing, testing & commissioning etc. as reqd as per standard practice, suitable for following types of Acs: 38 Split AC of 1.0/1.5/2.0 TR or equivalent capacity. 39 Casettee of 2.0-3.0 TR or equivalent capacity 40 Replacement of existing fitted faulty Condenser Cooling Fan Motor (AC/DC) with new one of same rating as per IS, i/c handling charges complete etc. as reqd, as per standard practice under buyback of old one, suitable for following types of ACs. 41 Split AC of 1.0/1.5/2.0 TR or equivalent capacity. 42 Casettee of 2.0-3.0 TR or equivalent capacity 43 Replacement of existing fitted faulty AC indoor unit blower motor (AC/DC) with new one of same rating as per IS i/c handling charges complete etc. as reqd as per standard practice under buyback of old one, suitable for following type of ACs. 44 Split AC of 1.0/1.5/2.0 TR or equivalent capacity. 45 Casettee of 2.0-3.0 TR or equivalent capacity 46 Repairing of existing faulty PCB of Inverter AC indoor unit including removing, fixing, testing & commissioning etc. as required. 47 Split AC of 1.0/1.5/2.0 TR or equivalent capacity 48 Casettee of 2.0-3.0 TR or equivalent capacity 49 Repairing of existing faulty PCB of Inverter AC outdoor unit including removing, fixing, testing & commissioning etc. as required. 50 Split AC of 1.0/1.5/2.0 TR or equivalent capacity 51 Casettee of 2.0-3.0 TR or equivalent capacity 52 Replacement of existing faulty PCB of Inverter AC indoor unit with new one of same rating & capacity including removing, fixing, testing & commissioning etc. as required under buyback 53 Split AC of 1.0/1.5/2.0 TR or equivalent capacity 54 Casettee of 2.0-3.0 TR or equivalent capacity 55 Replacement of existing faulty PCB of Inverter AC outdoor unit with new one of same rating & capacity including removing, fixing, testing & commissioning etc. as required under buyback 56 Split AC of 1.0/1.5/2.0 TR or equivalent capacity 57 Casettee of 2.0-3.0 TR or equivalent capacity 58 Replacement of existing faulty Running Capacitor of AC with new one of same rating as per IS including removing, fixing, testing & commissioning etc. as reqd, as per std practice. 59 Split AC of 1.0/1.5/2.0 TR or equivalent capacity 60 Casettee of 2.0-3.0 TR or equivalent capacity 61 Repairing of existing faulty 01 Ph, 240 V, 50 Hz, AC Voltage Stabilizer/Regulator including removing, fixing, testing & commissioning etc. as reqd as per std practice. 62 Supply of remote for all types of inverter AC 63 Replacement of existing burnout Compressor with new Compressor of same rating as per IS for 80 Ltr Bluestar/Usha Water Cooler i/c installation, testing & commissioning alongwith charged gas (green gas) i/c pressure testing as per standard practice complete in all respects and handling charges under buyback. (Make: Emerson Copeland/ Tecumseh). 64 Replacement of existing burnout Compressor with new Compressor of same rating as per IS for 80 Ltr Bluestar/Usha Water Dispenser i/c installation, testing & commissioning alongwith charged gas (green gas) i/c pressure testing as per standard practice complete in all respects and handling charges under buyback. (Make: Emerson Copeland/ Tecumseh). 65 Charging of suitable refrigerant gas (green gas) for water coolers i/c flushing of gas, leakage detection, testing, replacement of filter brazing joints etc. as required as per standard practice. Make: Bluestar/Usha 80 Ltrs capacity 66 Charging of suitable refrigerant gas (green gas) water dispensers i/c flushing of gas, leakage detection, testing, replacement of filter brazing joints etc. as required as per standard practice. Make: Bluestar/Usha 67 Supplying & Replacement of Relay ISI Marked suitable for water coolers/water dispenser of Make: Bluestar/Usha 68 Supplying & Replacement of Thermostat ISI Marked suitable for water coolers/water dispenser of Make: Bluestar/Usha 69 Replacement of existing faulty 01 ph, 230V 50 Hz 60-80W fan motor with new one of same rating as per IS including removing, fixing, testing & commissioning etc. as required as per standard practice under buyback. Make: Bluestar/Usha, 80 Ltr Capacity 70 Replacement of existing faulty Water-Cooled Condenser (Copper) with new one of same rating/size as per IS including removing, fixing, testing & commissioning etc. as required as per standard practice under buyback. Make: Bluestar/Usha, 80 Ltr Capacity . Last date of submission for this tender is 2025-11-18. This is a Air Conditioner tender in Goa, Goa

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

2 issued
  • Tender Document 1pdf
  • Tender Document 2html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in