🎉 Your free trial plan has started. Plan will expire in 0 days

Goa Medical College

panaji, goa

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Goa Medical College has published Procurement Of Medical Consumables Items For Use By The Department Of Cardiovascular And Thoracic Surgery, Goa Medical College-Adult Membrane Oxygenatorwith hard shell Reservoir1. Should have Heparin free, hydrophilic polymer surface balance coating. 2. Should have open circuit configuration 3. Should have hard shell venous reservoir of capacity more than 4000ml. With built of cardiotomy reservoir with 30m filter capacity. 4. Should have blood flow range 0.5 ltr to 7 ltr/min. 5. Should have priming volume less than 200ml 6. Should have high efficiency heat exchanger positioned in post pump configuration. 7. Venous return port 1/2 with rotating facility. 8. Should have an auto vent facility. 9. port size : arterial outlet, venous outlet 3/8 Venous inlet 1/2membrane surface area 1.8 to 2.5m2 10. Should have sampling port. 11. US FDA and CE approval is required. 2 Adult Membrane Oxygenator with hard shell Reservoir with integrated arterial filter1. Should have Heparin free, hydrophilic polymer surface balance coating. 2. Should have open circuit configuration 3. Should have hard shell venous reservoir of capacity more than 4000ml. With built of cardiotomy reservoir with 30m filter capacity. 4. Should have blood flow range 0.5 ltr to 7 ltr/min. 5. Should have priming volume less than 200ml 6. Should have high efficiency heat exchanger positioned in post pump configuration. 7. Venous return port 1/2 with rotating facility. 8. Should have an auto vent facility. 9. port size : arterial outlet, venous outlet 3/8 Venous inlet 1/2membrane surface area 1.8 to 2.5m2 10. Should have sampling port. 11. US FDA and CE approval is required. 3 Small adultMembrane Oxygenator with hard shell Reservoir1. Should have a micro porous hollow fiber membrane Oxygenator 2. Should have open circuit configuration 3. Should have hard shell venous reservoir of capacity more than 3500ml. With built of cardiotomy reservoir with 30m filter capacity. 4. Should have blood flow range 0.5 ltr to 4 ltr/min. 5. Should have priming volume less than 200ml 6. Should have high efficiency heat exchanger positioned in post pump configuration. 7. Venous return port 1/2 with rotating facility. 8. Should have an auto vent facility. 9. port size : arterial outlet, venous outlet 3/8 Venous inlet 3/8 10. Should have sampling port. 11. US FDA and CE approval is required. 4 Small adult MembraneOxygenator with hard shell Reservoir with integrated Arterial filter 1. Should have a micro porous hollow fiber membrane Oxygenator with integrated Arterial filter 2. Should have open circuit configuration 3. Should have hard shell venous reservoir of capacity more than 3500ml. With built of cardiotomy reservoir with 30m filter capacity. 4. Should have blood flow range 0.5 ltr to 4 ltr/min. 5. Should have priming volume less than 200ml 6. Should have high efficiency heat exchanger positioned in post pump configuration. 7. Venous return port 1/2 with rotating facility. 8. Should have an auto vent facility. 9. port size : arterial outlet, venous outlet 3/8 Venous inlet 3/8 10. Should have sampling port. 11. US FDA and CE approval is required. 5 Paediatric Membraneoxygenatorwith hard shell Reservoir 1. Should have a micro porous hollow fiber membrane Oxygenator 2. Should have open circuit configuration 3. Should have hard shell venous reservoir of capacity more than 3500ml. With built of cardiotomy reservoir with 30m filter capacity. 4. Should have blood flow range 0.5 ltr to 3.5ltr/min. 5. Should have priming volume less than 140ml 6. Should have high efficiency heat exchanger position in post pump configuration. 7. Venous return port 3/8 with rotating facility and reducers 8. Should have an auto vent facility. 9. pot size : arterial outlet, venous outlet 3/8 Venous inlet 3/8 with reducers 10. US FDA and CE approval is required. 6 Paediatric Membrane Oxygenator with hard shell Reservoir with integrated Arterial filter1. Should have a micro porous hollow fiber membrane Oxygenator with integrated Arterial filter 2. Should have open circuit configuration 3. Should have hard shell venous reservoir of capacity more than 3500ml. With built of cardiotomy reservoir with 30m filter capacity. 4. Should have blood flow range 0.5 ltr to 3.5ltr/min. 5. Should have priming volume less than 140ml 6. Should have high efficiency heat exchanger position in post pump configuration. 7. Venous return port 3/8 with rotating facility and reducers 8. Should have an auto vent facility. 9. pot size : arterial outlet, venous outlet 3/8 Venous inlet 3/8 with reducers 10. US FDA and CE approval is required. 7 Neonatal Membrane Oxygenatorwith integrated Arterial filter1.Should have venous inlet 1/4. Arterial outlet port 1/4 tubing size. It should have least priming volume less than 60ml. Reservoir capacity should not less then 600ml.Should have reducers and inbuild Arterial filter 2.US FDA and CE approval is required. 8 Prosthetic Heart Valve Bileaflet Mitral Valve Prosthetic Heart Valve Bileaflet( Mitral) 1. Should have Bileaflet pyrolytic carbon disc valve 2. Should haveRadioopaque disc to be visualizes disc to be visualizes on x-ray & fluoroscopy and disc should be MRI compatible. 3. Should be of low profile & thromboresistance Characteristics and Patented Pivot design . 4. Should have Opening angle should be 80 - 85 5. Should have wide range of sizes for mitral 25mm to 35 mm. 6.Should have easy torque rotation and intraoperative adjustment should be possible. 7. Should haveSewing cuff should contain suture marker for accurate placement. 8.Should have Valve to be CE & USFDA approved 9 Prosthetic Heart Valve BileafletAortic ValveProsthetic Heart Valve Bileaflet( Aortic) 1. Should have Bileaflet pyrolytic carbon disc valve 2. Should haveRadioopaque disc to be visualizes disc to be visualizes on x-ray & fluoroscopy and disc should be MRI compatible. 3. Should be of low profile & thromboresistance Characteristics. 4. Should Opening angle should be 80 - 84 5. Should have Wide range of sizes for mitral 17 to 35 mm. 5. Should have Wide range of sizes for mitral 17 to 35 mm. 6. Should Easy torque rotation and intraoperative adjustment should be possible. 7. Should have Sewing cuff should contain suture marker for accurate placement. 8. Valve to be CE & USFDA approved 10 Prosthetic Heart Valve Bileaflet( Mitral) 1. Should have Bileaflet pyrolytic carbon disc valve 2. Should haveRadioopaque disc to be visualizes disc to be visualizes on x-ray & fluoroscopy and disc should be MRI compatible. 3. Should be of low profile & thromboresistance Characteristics. 4. Should Opening angle should be 80 - 84 5. Should have Wide range of sizes for mitral 23 to 35 mm. 6. Should Easy torque rotation and intraoperative adjustment should be possible. 7. Should have Sewing cuff should contain suture marker for accurate placement. 8. Valve to be CE & USFDA approved 11 Prosthetic Heart Valve Bileaflet (Aortic ) 1. Should haveBileaflet pyrolytic carbon disc valve 2. Should haveRadioopaque disc to be visualizes disc to be visualizes on x-ray & fluoroscopy and disc should be MRI compatible. 3. Should be of low profile & thromboresistance Characteristics. 4. Should haveOpening angle should be 80 - 84 5. Should have Wide range of sizes for Aortic 16 to 27 mm. 6. Should have Easy torque rotation and intraoperative adjustment should be possible. 7. Should have Sewing cuff should contain suture marker for accurate placement. 8. Valve to be CE &USFDA approved 12 introducer sheath 8.5FRintroducer sheath to match SG/Cco/CEDV/SVO2/REF Catheters 13 Peritonial Dialysis fluid 14 Peritonial Dialysis catheter 5 Fr 15 Disposable cautery hand switch pencil (valley lab) 16 Disposable Patient Cautery Pad with cable- ADULT(Valley Lab ) 17 PAED. DISP CAUTERY PATIENT PADS(Valley Lab) 18 Neonatal DISP CAUTERY PATIENT PADS(Valley Lab) 19 non absorbable braided polyster2-0 ½ circle double armtc 75 cms suture book 5 white 5 green 25/26 mm with pledgets6 x 3 x 1.5 mm SUTURE BOOK ( FOIL )6foils /box (10 sutures in a foil) 20 Pad roll 4 159 cms 21 CRRT Femoral Cathter 22 Drug Iintravenous sildenafil 23 Injection Levosimendon 12.5g 24 Injection Soda Bi Carbonate 8.5% 25 inj Papavarine 2ml ( 30mg papavarine/ ml ) ampoule 26 Multiple electrolyte solution ( PH;704) 1000ml . Last date of submission for this tender is 2025-07-03. This is a Medical Equipment tender in Panaji, Goa

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

3 issued
  • Tender Document 1html
  • Tender Document 2pdf
  • Tender Document 3pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in