🎉 Your free trial plan has started. Plan will expire in 0 days

Public Works Department

at site, delhi

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Public Works Department has published Repair And Routine Maintenance Of Air Conditioners , Servicing Of Existing Installed Wtac/Stac/Cgac Of 1 . 5 Tr & 2 . 0 Tr Capacity Ac And Water Coolers Of 80/150/250 Lph With The Help Of Spray Jet Machine , Checking & Inspection Of Unit , Greasing , Oiling Etc . I/C Chemical Cleaning Of Condensing & Cooling Coil With High Pressure Pump Changing The Air Filter , Checked & Tightening All Electric Connections , Testing The Machine Etc . As Reqd . ( Tentative Service Period From 01 . 03 . 2021 To 14 . 03 . 2021 ) , Supply & Charging R-22/410/407/32/134A Gas In The Existing Wtac/Stac / Ctac Of 1 . 5 /2 . 0 Tr Unit /Fridge I/C Pressure Testing , Flushing The System And Gas Charging Complete As Reqd . , Supplying & Replacement Of Following Capacity Compressor In The Existing Wtac/Ctac/Split Ac Making Copper Pipe Connection , Brazing Pressure Testing I/C Cutting The Copper Piping Dismantling Of The Old Compressor Complete As Reqd . , 1 . 5 Tr , 2 . 0 Tr , Providing & Replacement Wtac/ Stac/ Ctac Fan Motor Capacity 1/4 To 1/8 Hp Including Dismantling The Burned Motor From The Existing Unit & Fixing Of New Motor , Making Connections Testing , Commissioning Etc . As Reqd . , Supplying & Fixing 25 Mm Diameter Pvc Heavy Duty Pipe For Drainage In The Existing Split Type Ac Unit With Supporting Clamps Etc . Complete As Reqd . , Supplying , Fixing , Testing & Commissioning Of Interconnecting Copper Refrigerant Pipe Of Size Of 1/4 Discharge Side & 1/2 Suction Side From Indoor Unit To Outdoor Unit Alongwith Closed Cell Nitrite Rubber Insulation As Per Specification Properly Supported With Clamps Etc . Complete As Reqd . , Providing And Fixing Of ( 3X2 . 5 S . Q . Mm ) Pvc Insulated & Pvc Sheathed Copper Conductor Circular Flexible Cable And Commissioning Etc . As Required . , Relocating Of Existing Installed Stac Of 1 . 5 Tr & 2 . 0 Tr Capacity With Outdoor Unit , From Its Location To Another Location , I/C Testing & Commissioning Etc . As Required . , Supplying & Replacement Of Following Defective Spare Parts In The Existing Ac Unit I/C Connection Testing Etc . Complete As Required . , Running Capacitor 36Mfd/45Mfd , Starting Capacitor 80/100Mfd , Repair Of Damaged Pcb Of Indoor & Outdoor Unit Including Testing The Loose Connection , Testing The Machine Etc . As Reqd . , Supplying & Replacement Of Remote Control System With Remote ( Wireless / With Wire Remote ) For The Existing Installed Window Split Type Ac I/C All Interconnection , Testing And Commissioning Complete As Reqd . , Replacement Of Worn Out / Defective Copper Condenser Coil And Cooling Coil With New One Of The Same Size And Design Suitable For 1 . 5/2 . 0 Tr Split Type Ac Out Door Unit Including Brazing The All Copper Pipe With All Distribution Joints And Make Sure The Connections With Capillary Tube Linking Dryer Duly Proper Etc . Pressure Testing , Leak Detection , Making Vaccum And Charging Etc . Complete As Required , Providing , Fixing Suction / Discharge Valve Of 5/8 Inch And 1/4 Inch Of Split Air Conditioner Unit Including Brazing The Valve With Compressor Suction And Discharge Line Etc . As Required . , Supplying & Replacement Of Additional Pre Fabricated Internal Drain Hose Pipe Of Indoor Unit Of Suitable Size Including Connection Of The Outer Drainage Pipe And Making Sure To Leak Proof Etc . Complete As Required . , Supplying & Replacement Of Following Capacity Split Type Ac Indoor Unit I/C Testing , Commissioning Etc . As Required . , 1 . 5 Tr , 2 . 0 Tr , Supplying And Replacement Of Following Capacity Split Type Ac Outdoor Unit . , 1 . 5 Tr , 2 . 0 Tr , Comprehensive & Routine Maintenance Of Wtac/Stac/Ctac Unit And Water Cooler I/C Attending Day To Day Complaints From 9 Am To 5 Pm And Rectifying The Defects , Replacement Of Minor Worn Out Parts Such As Starting Relays , Selector Switches , Sleeve Knobs , Front Grills Connectors Etc . Which Required To Be Replace During Routine Maintenance & Monthly Cleaning By Blower Fan /Blower Motor , Coils Main Lead Etc . As Required . ( 95 Nos . X 8 . 0 Months = 760 Nos . ) ( Tentative Period From 15 . 03 . 2021 To 14 . 11 . 2021 ) , Credit For Dismantle Material . , Worn Out 1 . 5/2 . 0 Tr Capacity Compressor . , Burn Out Fan Motor 1 , 1/2 , 1/4 , 1/8 , , Refrigerant Copper Pipe , Condenser Coil , Running / Starting Capacitor , Split Type Ac Indoor Unit 1 . 5/2 . 0 Tr , Split Type Ac Outdoor Unit 1 . 5/2 . 0 Tr , Suction/ Discharge Valve . Last date of submission for this tender is 2021-02-24. This is a Spare Part tender in At Site, Delhi

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

4 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in