🎉 Your free trial plan has started. Plan will expire in 0 days

Public Works Department

ee(e),nwed, pwd emd m-353, isbt, kashmere gate, de, delhi

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Public Works Department has published Supplying, Installation, Testing And Commissioning Of Led Fittings At Forensic Science Laboratory, Madhuban Chowk, Sector - 14, Rohini, Delhi Dg 2021-22- 1 Sitc Of Surface Mounted 12 Watt To 15 Watt Led Downlighter Luminaire Made Out Of Epoxy Powder Coated Die Cast Aluminium In White Finish With Opal Diffuser With Minimum Lumens Output Not Less Than 100 Lumens Per Watt Suitable For Cool Day White Light Having Minimum Cct 5700K To 6500K, Power Factor Not Less Than >0.90, Cri> 80%, Complete With All Accessories Etc. Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable & Earthing Complete Etc As Required. ( Including Dismantling The Old Fitting If Any ) 2 Supplying, Installation, Testing And Commissioning Of Recess Mounted Type Luminaries, Glare Free Opal Diffuser Led Panel Of Nominal Size 595 X 595 Mm Suitable For Armstrong / Pop / Gb Ceiling With Made Out Of Crca Powder Coated Housing. Having The Following Specifications :I ) Total System Power - 34 To 36 Watt, Ii ) Color Temprature - 5700 K To 6500 K, Iii ) Power Factor - > 0.95Iv ) Cri - > 80, V ) System Lumen Efficency - =100 Lm / W, Complete With All Accessories Etc. Directly On Ceiling / Wall Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Reqd. ( Including Dismantling The Old Fitting If Any ) 3 Supplying, Installation, Testing And Commissioning Of Prewired, 20 To 22 Watt, 1200 Mm Long Led Batten Fitting With Aluminium Housing And Integrated Electronic Driver Wall Mounted Luminaire Having The Following Specifications :I ) Total System Power - Minimum 20 To 22 Wattii ) Color Temprature - 5700 K To 6500 Kiii ) Power Factor - > 0.95Iv ) Cri - > 80, V ) System Lumen Efficency - =100 Lm / W, Complete With All Accessories Etc. Directly On Ceiling / Wall Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Reqd. ( Including Dismantling The Old Fitting If Any ) 4 Supplying, Installation, Testing And Commissioning Of Pre-Wired 120 Watt , Ip 66 Led Flood Lightwall Mounted Luminaire Made Out Of Pdc Aluminium Body With Minimumlumens =100 Lumen Per Watt Suitable For Cool Daywhite Lighthavingminimum Cct 5700K, Power Factor >0.90, Cri > 70%Complete With All Accessories Etc. Directly On Ceiling / Wall Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. ( Including Dismantling The Old Fitting If Any ) 5 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. A ) 5 / 6 A Switch 6 B ) 3 Pin 5 / 6 A Socket Outlet 7 C ) 15 / 16 A Switch 8 D ) 6 Pin 15 / 16 A Socket Outlet 9 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. A ) 8 Module ( 125 Mmx125 Mm ) 10 B ) 12 Module ( 200 Mmx150 Mm ) 11 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 A & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 12 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point / Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable In Existing Surface / Recess Steel / Pvc Conduit In Group Control Wiring Including Dismantling Etc As Required.A ) Group C 13 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.A ) Group C 14 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. A ) 3 X 1.5 Sq. Mm 15 B ) 6 X 1.5 Sq. Mm 16 C ) 3 X 4 Sq. Mm 17 D ) 6 X 4 Sq. Mm 18 Supplying, Fixing Testing Commissioning Of Supply Air Diffusers Of Powder Coated Aluminium With Aluminium Volume Control Dampers With Anti Smudge Ring & Removable Core. 19 Credit For Old Dismantled Materiala ) 1 X 40 Watt Fluorescent Fitting 20 B ) 2 X 40 Watt Fluorescent Fitting. Last date of submission for this tender is 2021-09-28. This is a Other Adhesives And Sealants tender in Ee(e),nwed, Pwd Emd M-353, Isbt, Kashmere Gate, De, Delhi

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

4 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in