🎉 Your free trial plan has started. Plan will expire in 0 days

New Delhi Municipal Council

shivaji stadium, delhi

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

New Delhi Municipal Council has published Annual Repair And Maintenance Of fire alarm , detection and pa cum talk back system at various ndmc buildings during 2020-21 . sh- annual maintenance contract and replacement of addressable fire alarm accessories at shivaji stadium . , amc for addressable fire alarm system ( secutron make ) including weekly visits by the team consisiting of engineer , technicians & helpers with the aim to keep the system functional round the clock including servicing , maintenance , testing , checking the loops using software and keeping them in order round the clock and cleaning the system internally as well as externally complete to the entire satisfaction of fire officer / engineer in charge . the inventory installed in the buildings is available at the respective control room . shivaji stadium ( secutron make ) a ) engineer - 1 no . - 01 visit / week b ) technical foreman - 01 no . - 01 visit / week c ) helper - 02 nos . - 01 visit ( each ) / week note : atleast 01 visit / week / building is required by the team consisting of 01 engineer , 01 technician and 02 helpers , engineer , technician , helper , replacemnt , supply , installation , testing and commissioning of microprocessor based networkable intelligent addressable 15 loop ( expandable upto 17 loop ) main fire alarm control panel central processing unit with analog loop controller ( 159 sensors & 159 modules ) , conventional adder module loops ( max 8 cards per loop ) , 20 character by 4 line back-lit lcd display , 4 class a / b ( style z / y ) indicating ccts @ 1 . 7 amps each four event display queues , 12 amp power supply , 16 zone alarm , supervisory & trouble led configurable annunciator , common alarm , supervisory & trouble contacts , c / w space for fnc-2000 fire network controller module , 16 adder modules , 3 internal annunciation modules , backbox enclosures for midsize mmx-2000n , mmx network quad loop controller module with built-in isolation , provides two intelligent loops ( 318 sensors & 318 modules ) , expanded to four loops with alcn-792d daughter module , 48 hours backp up with 24volt sealed maintenance free batteries with automatic charger . the panel shall have facility to connect printer to printout log and shall be complete with all accessories . the panel shall be compatiable for ibms system with open protocol bacnet / modbus over ip complete as per specifications . i / c programing the existing 15 loops and clear the faults etc . complete as required . , replacement / s / i / t / c of relay output module as per mri-m500s complete in all respect to the entire satisfaction of fire officer . ( make secutron only ) , replacement / s / i / t / c of call point-break glass type ( non ul ) having dust tight emergency push button to indicate audio and visual alarm with breakable glass cover with steel hammer attached with steel chain strictly as per mcp 5a-rp01ff-01 etc complete in all respect to the entire satisfaction of fire office ( make secutron only ) , replacement / s / i / t / c of addressable photo smoke detector as per part no . mri-2251tmb as per the site requirement etc complete in all respect to the entire satisfaction of fire officer . ( make secutron only ) , supplying & laying of 2x1 . 5 sqmm fire alarm armoured cable , 600 / 1000v rated with annealed copper conductor having xlpe insulation , steel wire armouring & frls red colour outer sheath complete as required , credit of unservicable material in all respeect to the entire satisfaction of fire officer , relay out put module , call point-break glass type , addressable photo smoke detector. Last date of submission for this tender is 2020-09-30. This is a Fire Alarm Systems tender in Shivaji Stadium, Delhi

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

2 issued
  • Tender Document 1pdf
  • Tender Document 2html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in