🎉 Your free trial plan has started. Plan will expire in 0 days

Delhi Urban Shelter Improvement Board

delhi, delhi

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Delhi Urban Shelter Improvement Board has published Tender For Pay & Use Jsc (Revenue)Sh: Re - Boaring Of Tubewell Bore For 39 Seater Jsc At Narden Jhuggi, S. P. Crusher, M.B. Road. (49Cj0822); 1 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore 2 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 40 mm diameter pipe 3 Providing and filling sand of grading zone V or coarser grade all- round the G.I. pipes in external work. 40 mm diameter pipe 4 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 40 mm nominal bore 5 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. Rocky strata including Boulders 300 mm dia 6 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Rocky strata including Boulders 300 mm dia 7 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in-charge. 8 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia having minimum wall thickness 5.00 mm 9 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm 10 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumastic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 11 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumastic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia 12 Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 200 mm dia 14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp 15 Providing following submersible pump set and accessories i/c lowering of pump set suitable by using tripod stand & chain pulley etc. and fixing of the accessories & connections etc as reqd. (1) Duties of pump set:- (a) Medium clear water (b) Head range:-71-136 mtr ©Discharge range:- 6-2 M3 /Hr (d) Delivery dia:- 40 mm (e) Pump type- Make KSB water cooled model CORA 4C/23 operated on. (2)S/F of control panel board complete with ammeter Voltmeter starting capacitor 200/250 HF running capacitor of 75 MF over load relay 17.4-24 Amp. And ON/OFF switch buttens etc. (MR) (BCH/Havells make) 1 no. (3)S/FGun Metal NRV of size 40 mm dia etc. (ISI Mark) - 01 no. (4) M.S. Clamp set suitable size complete with nut bolts - 02 set (5) M.S. bore cover cap -01 no these item are includes provision , lowering/fixing , testing and commissioning of aforsaid pump set & accesorries as reqd. (MR) 16 S/F of PVC insulated and PVC sheathed copper flat sub . Cable following size tc as reqd. (MR) ISI mark (a) 3X4 sq.mm 17 S/F of 40 mm dia GI pipe medium class i/c making water tight connection etc as reqd. (ISI mark) Mr Jindal, Prakash, Surya and Shrikrishna make. 18 S/F of 40 mm dia GI socket /elbow i/c making water tight connectionetc as reqd. ISI mark (MR) 19 S/F heavy duty GI flanges suitable for 40/50 mm dia GI pipe i/c 15mm 4 nos. nuts and bolts for sub. p/set etc i/c rubber packing as reqd. (MR) 20 S/F steel rope of 6mm dia for protection of pump as rqd. 21 Add as circulated by CPWD 31.27% cost index on item No. 1 to 14 i.e. on Rs. 5,43,263.78 22 Deduct as circulated by GNCTD (-) 9.50 % . Last date of submission for this tender is 2025-10-31. This is a Tube Well tender in Delhi, Delhi

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

3 issued
  • Tender Document 1html
  • Tender Document 2pdf
  • Tender Document 3pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in