🎉 Your free trial plan has started. Plan will expire in 0 days

Delhi University

delhi, delhi

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Delhi University has published Replacement Of Defective Existing Fitting With Led 18 Watts Pll And Provision Of Power Points And Other Allied Work To Be Carried Out In Room No. 2, 3, 11, 12, 13, 17, 26, 33, 22, 21, 301, 302, 306 And Lab No. 26, 22, 17, 306, 310, 311, 312, 313 In Department Of Botany And Seminar Hall And Rooms Of Conference Centre, University Of Delhi ; 1 S / F The Following Size / Modules G.I Box Along With Modular Base And Cover Plate For Modular Switches In Recess Etc As Reqd. 2 6 Module 3 8 Module 4 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 5 1 X 1.5 Sq.Mm 6 2 X 2.5 Sq.Mm 7 2 X 4 Sq.Mm 8 2 X 6 Sq.Mm 9 Wiring For Circuit / Submain Wiring Longwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 4 X 16 Sq. Mm + 2 X 16 Sq. Mm Earth Wire 10 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 11 5 / 6 Amps Switch 12 3 Pin 5 / 6 Amps Socket Outlet 13 15 / 16 Amps Switch 14 6 Pin 15 / 16 Amps Socket Outlet 15 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 16 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required.Group C 17 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 18 Supplying And Making Straight Through Joint With Heat Shrinkable Kit Including Ferrules And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 3½ X 120 Sq. Mm 19 Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. 200 A, 35 Ka Tpmccb 20 Supplying And Fixing Of 18 Watts Led 4 Pin Pll 1700 Lumens Tube Dimension 1200X32x26 With Colour 6500 In The Existing Fitting Including Making Connection Etc. As Required At Site. ( Philips ) 21 Finding And Detecting Location Of Underground Lt Cable With Flc Machine Including Excavation, Pin Pointing, Fault , Refilling After Repair Of Ground At Marked Fault As Required At Site. 22 Making Provision Of Digging Out The Fault Location Upto 10 Mtr For Making Connection Straight Through Joint By Tracing Out The Loop And Then Refilling The Trench After Restoring The Electric Supply Etc. As Required. 23 Supplying, Fixing And Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Armoured Conductor Power Cable Confirming To 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation Sand Cushioning , Protective Covering , Refilling The Same Etc. As Required. 3½ X 185 Sq. Mm 24 Supplying And Fixing Following Rating, Tpn Mcb 415V In The Existing Mcb Db Complete With Connection, Testing And Commissioning Etc. As Required. 25 Servicing / Cleaning / Meggering / Checking Of Load Balancing / Checing With Ton Tester Of Existing Panel I / C Removing The Dust And Carbonized And Dress Up The Hanging Wire Along With Thimble If Necessary Etcas Required At Site. 26 S / F Of Single Box Type Fitting Complete With All Accessories I / C Making Connection Etc. As Required. Tmc 502 1Xt- Led 22W P3242 I / C Having 1 Nos. Of Stellar Bright 20Watts Led Tubelight In The Existing Fitting As Required. 27 Supplying And Fixing Of 48 Ceiling Fan Including 3 Fan Rod And Making Connection Etc. As Required At Site. ( Crompton / Havells ) . Last date of submission for this tender is 2023-09-18. This is a Cushioning Supplies tender in Delhi, Delhi

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

3 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in