🎉 Your free trial plan has started. Plan will expire in 0 days

Delhi Jal Board

chief water analyst (w n s)-iii, delhi

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Delhi Jal Board has published Nit No . 09 Procurement Of Dpd Powder ( Pouch ) As Per Specifications And Bq Make Thermofisher , Lovibond , Palintest , Specification For Dpd Powder For Determination Of Free Chlorine In Treated Water Or Treated Waste Water The Dpd ( N , N-Diethyl-1 . 4-Phenylendiamine ) Powderpouch For Single Test Of Residual Chlorine Is Required For Measuring Range Between 0 . 02 To 3 . 5 Mg / L In Chlorine Treated Water Or Waste Water Through Any Potometer / Spectrophotometer At The Wave Length Of 530 Nm If Sample Is Taken In The Cuvette Of 24 Mm . Specified Data For Procedure Sensitivity ( Slope ) Of 1 Mg / L 0 , 43 Ext . / ( Mg / L ) Limit Of Detection ( Blanc Procedure 3 X S ( Blanc ) ) 0 , 01 Mg / L Limit Of Quantification ( Blanc Procedure ) 9 X S ( Blanc ) 0 , 03 Mg / L Confidence Interval ( 95% ) + / - 0 , 049 Mg / L Method Standard Deviation 0 , 021 Mg / L Method Variation Coefficient + / - 1 , 13 % Specified Data For Determination / Procedure Will Be In Accordance With Iso 8466- 1 And Din 38402 A51 Shelf Life: 5 Years Packaging: Individual Stick Like Air Tight Sealed Pack With Narrow Geometry Ensuring Moisture Free And Long Shelf Life Of The Reagent . , Specification For Dpd Powder For Determination Of Total Chlorinein Treated Water Or Treated Waste Water The Dpd ( N , N-Diethyl-1 . 4-Phenylendiamine ) Powder Pouch For Single Test Of Residual Chlorine Is Required For Measuring Range Between 0 . 02 To 3 . 5 Mg / L In Chlorine Treated Water Or Waste Water Through Any Potometer / Spectrophotometer At The Wave Length Of 530 Nm If Sample Is Taken In The Cuvette Of 24 Mm . Specified Data For Determination / Procedure Will Be In Accordance With Iso 8466- 1 And Din 38402 A51 Specified Data For Procedure Sensitivity ( Slope ) Of 1 Mg / L 0 , 43 Ext . / ( Mg / L ) Limit Of Detection ( Blanc Procedure ) 3 X S ( Blanc ) 0 , 01 Mg / L Limit Of Quantification ( Blanc Procedure ) 9 X S ( Blanc ) 0 , 03 Mg / L Confidence Interval ( 95% ) + / - 0 , 049 Mg / L Method Standard Deviation 0 , 021 Mg / L Method Variation Coefficient + / - 1 , 13 % Shelf Life: 5 Years Packaging: Individual Stick Like Air Tight Sealed Pack With Narrow Geometry Ensuring Moisture Free And Long Shelf Life Of The Reagent .. Last date of submission for this tender is 2021-03-18. This is a Chemical Supply tender in Chief Water Analyst (w N S)-iii, Delhi

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

3 issued
  • Tender Document 1pdf
  • Tender Document 2pdf
  • Tender Document 3html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in