Central Public Works Department
- AOC value
- ₹87.91L
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Authority
- Central Public Works Department
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Central Public Works Department has published Supply, Installation, Testing And Commissioning Of Security Equipments At Gate No. 1 Of Hyderabad Houses-Supply, Installation, Testing And Commissining Of Boom Barrier Gate Not Less Than 2.6 Mtr Or Upto 3 Mtr Straight Arm With Following Features: * 2-6 Seconds Opening Time/Closing Time (Adjustable). * 100% Duty Cycle. * Bldc Motor Operated. * Boom Swing Away Function (I.E. Boom Shall Have Breakaway Flange To Prevent From Breaking When Hit By A Vehicle * Manual Operation In Case Of Power Failure. * Auto-Reverse Function To Enable Barrier Arm To Reverse Back As Soon As It Touches To An Obstruction During The Closure Cycle, Preventing Injury To Human Or Vehicle Damage. A. Gate No.-1 I/C Connection Etc Complete As Required. 2 Nos. 2,32,273.00 Each 4,64,546.00 2 Supply, Installation, Testing And Commissining Of Led Traffic Light, 24 Volt, Red Or Green Colour With Complete Housing And Ip65 Protection For Outdoor Use, Complete With Mounting Arrangement I/C Connection Etc Complete As Required. 2 Nos. 56,537.00 Each 1,13,074.00 3 Supply, Installation, Testing And Commissining Of Ir Beam Photo Sensors For Safety At All Boom Barrier/ Bollard Systems, Including Cabling/Ducting Required Including The Rx Or Tx Modules Operated On 24Vdc And Having Potentialfree Contacts Of No/Nc. The Safety Sensors Are Installed On Ms Poles Which Are Powder Coated Having Base Plate To Bolt Down And Provision For The Rx Or Tx Modules To Fix On The Same Along With Cables Entry To Terminate. The Sensors Will Have Adjustable Eye To Align The Ir Beam Within The Range Of Minimum 10 Mtrs I/C Connection Etc Complete As Required. 4 Nos. 63,836.00 Each 2,55,344.00 4 Supply, Installation, Testing And Commissining Of Interlocking Relay Circuit Panel For Integrating Boom Barrier And Bollards With Raise/Lower Proximity Limits To Automatically Control Traffic Lights. Also Providing Power Supply For Relay Circuit Of 12V, 1.5Amp Rating Along With Re-Programming Of The Controller For Boom Barrier Integration With Raise/Lower Commands For Traffic Light Functions, Including Cabling And Ducting Works I/C Connection Etc Complete As Required. 2 Nos. 62,218.00 Each 1,24,436.00 36 5 Supply, Installation, Testing And Commissining Of Rfid (Radio Frequency Identification System) Consisting Of Following Accessories/Equipment: To Control The Electrically Operated Bollards And Boom Barriers. A) Proximity Cards/Rfid Tags Along With Facility Code – 50 Nos. B) Main Controller For Rfid Access Control System Using Long Range Readers And Tags - 1 Job C) Long Range Proximity Card Readers/ Rfid Readers Of 10-12 Mtrs Read Range With Suitable Mounting Arrangement On The Existing Structure For Outdoor Applications And Should Be Compatible With Boom Barrier Integration - 1 Nos. D) The System Shall Also Be Provided With A Access Control Software. Complete Software For Access Control Of Authorized/Un-Authorized Entries And Exits With The Intelligence To Communicate With The Controller For Allowing The Barrier Operation To Open/Close. The Software Shall Be Capable Of Providing Detailed Reports In Any Format Excel/Pdf For Generating Weekly / Daily / Monthly Reports And Also Blacklisting Any Vehicle Access. The Software Also Allows To Add And Remove The Rfid Tags And Also Re-Issue Or Allow Temporary Removal. The Ui Of The System Is Easy And Friendly With Each Log Provided With The Details Of Time/Date/Gate Number/Vehicle Details Etc. And Must Have User Capacity Of Minimum 5000 Users And Log Capacity Of 100,000. I/C Connection Etc Complete As Required. 1 Nos. 9,61,315.00 Each 9,61,315.00 6 Supply, Installation, Testing And Commissining Of K4 Crash Rated Electro Hydraulic Bollard System, Suitable To Work On Three/ Single Phase 400/230 Volts 50Hz Ac Supply Consisting Of Hydraulic Power Unit, Microprocessor Based Logic Circuits Complete As Per Mentioned Technical Details Complete As Required As Per Specifications, Operational Training Etc.A. Height – Minimum – 900 Mmb. Bollard Dia - Minimum - 220 Mmc. Tested At 7.2 Ton Vehicle @50 Km/Hr, Dos K4 (Phycally Impact Tested At Any Globally Accepted Testing Agency)D. Operation Time Time 5 To 8 Sec. Max.E. Frequency Of Operation - 200 Full Cycles / Hrf. Power Of Operation – Minimum Three Full Cycle Operationg. Manual Operation – Integrated Hand Pumph. Safety Interlock Detectori. Circular Illumination (Led) Unit On Top Of Bollardj. Outdoor Control Panel – Up/Down/Stop/Middle Stop Operation & 37 Maintenance Switchk. Operating Temp Range – 20 To +60 Deg C And Capable Of Meeting The Rain Fall And Snow Fall Requirement At Various Sites.L. Suitable Earthing Including Supplying Of Cable/ Dbs And Laying And Termination Etc.M. Bollards Will Be Able To Withstand Load Tolerance Of 20Kn.N. The System Will Have Submersible Pumps With Auto Cut Off/On Feature To Clear The Water From The Sump Pits I/C Connection Etc Complete As Required. A Gate No- 1 3 Nos. 10,57,287.00 Each 31,71,861.00 7 Sitc Of Under Vehicle Scanning System With Dismentling Of Old Uvss System And Carryout Required Modification To Floor/Foundation As Per New Machine Layout, Construct Or Repairing Machine Foundation, Treanches Or Support Structure, Necessary Cutting, Plastering, Leveling And Finishing Works , Ensure Proper Aligment, Leveling For Installation, Restore Damage Areas Caused During Dismentling Or Installation Having Following Specifications I/C Buyback Of Old Dismentled Uvss System I/C With All Accessories:- Principal The Under Vehicle Inspection System Provides An Image Of High Quality Resolution For Easier Inspection, Observation And Identification Of Suspicious Or Foreign Objects By The Operator. The Undercarriage Of The Vehicle Will Be Shown As A Single Picture Without Any Obstruction.The System Is Able To Record The Undercarriage Images, And Affix To Each Record, Details Like Entry/Exit, Date, Time, Etc. The System Is Able To Work At All Times Of Day Or Night And During All Types Of Weather Conditions. Techanical Specification The Under Vehicle Inspection System Is Able To Record The Undercarriage Images Of Vehicles In Motion Without Requiring To Be Fully Stopped And Display These As A Composite & High Resolution Image On The Monitor(S). The System Take Into Consideration The Different Heights Of The Undercarriage (Truck/Car), Widths And The Lengths Of The Vehicles As They Pass Over The System.. Last date of submission for this tender is 2026-06-09. This is a Gate Barrier Systems tender in Delhi, Delhi
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
2 issued- Tender Document 1htmlHTML document
- Tender Document 2xlsXLS document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free