🎉 Your free trial plan has started. Plan will expire in 0 days

Public Health Engineering Department

kamrup, assam

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Public Health Engineering Department has published Tender For Empanelment Of Agencies For Supply Of Different Laboratory Instruments For Various Water Testing Laboratories Under Jal Jeevan Mission, Assam. , Ion Meter With Electrode And Accessories For Fluoride & Nitrate Meter: Ph/Ion/ Mv-Redox-Orp/ Temperature Benchtop Meter With Electrode For Testing Both Fluoride & Nitrate Separately In Water Samples. Technical Specification: Ph Range: -2.000 To 20.000 Resolution 0.1, 0.01, 0.001 Accuracy ±0.002 Ph + 1 Lsd Calibration Points Up To 5 Buffer Sets: Usa/ Nist/ Din/ Custom Orp Range ±2000.0 Mv Rel. Mv Range ±2000.0 Mv Accuracy ±0.2 Mv Resolution 0.1 Mv Ion Concentration 0.001 To 19999 Ppm Resolution Up To 3 Digits Relative Accuracy ±0.5 % Full Scale (Monovalent) And 1 % Full Scale (Divalent) Calibration Points Up To 8 Temperature Range 0 To 100 °C, 32 To 212 ºf Resolution 0.1 Accuracy ±0.3 °C/ ±0.5 ºf Compensation: Auromatic Temperature Correction Other Requirement: Auto Buffer Recognition, Memory 500 With Time And Date Stamp Rs 232 Alarm For Calibration Due & Out Of Range Alurm Auto Logging Function. , Fluoride Electrode Of Ion Meter Same Make That Of The Ion Meter , Nitrate Electrode Of Ion Meter Same Make That Of The Ion Meter , Manifold Filtration Assembly (To Be Used For Micobiological Test) * Sturdy And Easy To Clean Ss Filtration Assembly With Funnel, Manifold Unit, Air Vent Filter And Vaccum Pump Ready To Be Used For Mictobiological Testing * Specification: Funnel With Inbuilt Clamp: Made Of Ss 316, Capacity: 300 Ml, Ss Filter Support Base, Ss Support Screan: 47 Mm, Made Of Ss 316L; Filtration Area 9.6 Cm2; Silicon Stopper: Size 8, With Silicon Lid And Silicon O Ring. Filtration Manifold: 3 Place Manifold, Made Of Ss 316, Valves Made Of Ptee, Connection 12 Mm; Suitable For Both Pp And Ss Funnel With Rubber Stopper Fittings. Vacuum Pump: Oil Free, Piston Powered, Suitable To Be Used With 3 Possition Manifold; Max Flow Rate: 34 L/ Min; Vaccum Stage: Double. Max Vaccum: 100 Mbar. The Vaccum Pump Should Also Have A Vacuum Suction Bottle To Protect The Pumps Componennt By Preventing Liquid Or Solid Material From Entering The Pump During Filtration Process. , Voltage Stabilizer (3 Phase) Capacity- 3 Kva Input Voltage Range: 295 V - 465 V Normal Range Output Voltage Range 380 V / 400 V / 415 V Output Regulation: ± 1 %; Output Settability: 380 V - 420 V; Frequency: 47 Hz - 53 Hz; Correction Rate: 70 V/ Sec; Aircooled Servo Stabilizer, Three Phase. , Heating Mantle (Single Station) ? Should Have Safety Cut Off With Precise Heating For Boiling, Evaporation, Distillation Or Extraction Process ? Technial Specification: Flask Capacity 250 Ml, Working Temp Range: Ambiant + 5 To 350 Degree Celcius. Accuracy: 1.0 Degree Celcius, Display: Led Display With Temperature, Time; Construction Material: Ms; Power Consumption : 150 W , Semi Automatic Digestor For Cod Analysis With All Assssories Material Of Construction - Epoxy Painted With Chemical Resistant Coating; Temperature Range - Ambient To 450 Deg C Stability Of Temperature - ± 0.5 Deg C Temperature Calibration - Automatic; Selectable Ramp: Upto 4 Per Program; Digestion Time Range: 1 To 999 Minutes; Time Selection: 1 Minutes Steps; Countdown: Digital Readout; Heating Places - 6 Possition; Size Of Tubes: 250 Ml Test Tubes (42 Mm); Power 1000 W; Number Of Programmable Methods - 20 Numbers. The Thermal Digestion Unit Should Have High Thermal Homogeneity The Setup Should Have Small Footprint. , Digital Thermometer With Probe Mini Lcd Thermometer Type: Digital, Sensor Cable Length: 1 Meter Water Proof Probe Batteries: 2 X Batteries Should Be Included, Temperature Range: - 50 - 110 Oc, Temperature Measurement Accuracy: ± 1 0C , Micropippete Stand #Self-Standing Holder Accommodates Most Major Brands Of Pipettes. #Material: Pmma, Capacity: 5 Pipptes/Stand , Conical Flask Draining Rack #Material: Acrylonitrile-Butadiene-Styrene/Polycarbonate, No. Of Pegs: 20,. Last date of submission for this tender is 2026-02-13. This is a Laboratory Equipment tender in Kamrup, Assam

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

3 issued
  • Tender Document 1html
  • Tender Document 2pdf
  • Tender Document 3pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in