Numaligarh Refinery Limited
- AOC value
- Refer Docs
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Authority
- Numaligarh Refinery Limited
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Numaligarh Refinery Limited has published Tender for Supply Of Medium Voltage Cables (Lot-2) For Msb,Gds And Pfcc Unit Of Nrep , Supply Of Mv Cables As Specified In Mr Including Design, Engineering, Manufacturing, Inspection, Factory Acceptance Testing (Fat), Supply, Dispatch Of Medium Voltage Cables , Group 1 Power Cables: Stranded Aluminium Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls) , 3C X 35 Sq. Mm (A2xfy) , 3C X 50 Sq. Mm (A2xfy) , 3C X 70 Sq. Mm (A2xfy) , 3C X 95 Sq. Mm (A2xfy) , 3C X 120 Sq. Mm (A2xfy) , 3C X 150 Sq. Mm (A2xfy) , 3C X 185 Sq. Mm (A2xfy) , 3C X 240 Sq. Mm (A2xfy) , 3C X 300 Sq. Mm (A2xfy) , 4C X 25 Sq. Mm (A2xfy) , 4C X 35 Sq. Mm (A2xfy) , 4C X 50 Sq. Mm (A2xfy) , 4C X 70 Sq. Mm (A2xfy) , 4C X 95 Sq. Mm (A2xfy) , 4C X 120 Sq. Mm (A2xfy) , 4C X 150 Sq. Mm (A2xfy) , 4C X 185 Sq. Mm (A2xfy) , 4C X 240 Sq. Mm (A2xfy) , 4C X 300 Sq. Mm (A2xfy) , 1C X 630 Sq. Mm (A2xway) , Group 2 Power Cables: (Fire Resitant) Fire Survival Cable, Stranded Copper, Epr Insulated Or Equivalent Material With Glass Mica Tape Insulation, Armoured, Inner And Outer Sheath As Per Relevant Iec Standards (A) The Insulation Shall Be Of Epr Or Equivalent Material With Glass Mica Tape Below Or Above Insulation. (B) Unless Otherwise Specified The Cables Shall Meet Requirement Of Circuit Integrity Test For A Minimum Period Of 3 Hours At Max. Temperature Of 950°C. , 4C X 2.5 Sq. Mm (2Xwy) -- For Mov , 12C X 2.5 Mm2 : E4-0.6/1.1-Mcxcx(C)-2.5(12C)Nk (For Rxrg Contractor) , 19C X 2.5 Mm2 : E4-0.6/1.1-Mcxcx(C)-2.5(19C)Nk (For Rxrg Contractor) , Group 3 Power & Control Cables: Stranded Copper Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls) , 3C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Tcoco(I/C)-1.5(3C)B : (For Rxrg Contractor) , 5C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Mcoco(I/C)-1.5(5C)K : (For Rxrg Contractor) , 10C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Mcoco(I/C)-1.5(10C)K : (For Rxrg Contractor) , 12C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Mcoco(I/C)-1.5(12C)K : (For Rxrg Contractor) , 3C X 2.5 Sq. Mm (2Xwy) , 3C X 4 Sq. Mm (2Xwy) , 3C X 6 Sq. Mm (2Xwy) , 3C X 10 Sq. Mm (2Xwy) , 3C X 16 Sq. Mm (2Xfy) , 3C X 25 Sq. Mm (2Xfy) , 3C X 35 Sq. Mm (2Xfy) , 3C X 50 Sq. Mm (2Xfy) , 3C X 70 Sq. Mm (2Xfy) , 3C X 95 Sq. Mm (2Xfy) , 3C X 120 Sq. Mm (2Xfy) , 3C X 150 Sq. Mm (2Xfy) , 3C X 240 Sq. Mm (2Xfy) , 3C X 300 Sq. Mm (2Xfy) , 1C X 630 Sq. Mm (2Xway) , 4C X 2.5 Sq. Mm (2Xwy) , 4C X 4 Sq. Mm (2Xwy) , 4C X 6 Sq. Mm (2Xwy) , 4C X 10 Sq. Mm (2Xwy) , 4C X 16 Sq. Mm (2Xwy) , 5C X 2.5 Sq. Mm (2Xwy) , 7C X 2.5 Sq. Mm (2Xwy) , 8C X 2.5 Sq. Mm (2Xwy) , 10C X 2.5 Sq. Mm ## , 12C X 2.5 Sq. Mm ## , 14C X 2.5 Sq. Mm ## , 12C X 2.5 Sq. Mm ##: E3-0.6/1.1-Mcoco(C)-2.5(12C)Nk - (For Rxrg Contractor) , 16C X 2.5 Sq. Mm ## , 19C X 2.5 Sq. Mm ## : E3-0.6/1.1-Mcoco(C)-2.5(19C)Nk - (For Rxrg Contractor) , Group 4 Lighting Cables: Stranded Copper Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls : Red, Black & Green) , 3C X 2.5 Sq. Mm (2Xwy) , 3C X 16 Sq. Mm (2Xfy) , 3C X 4 Sq. Mm (2Xwy) , Supply Of Mv Cables As Specified In Mr Including Design, Engineering, Manufacturing, Inspection, Factory Acceptance Testing (Fat), Supply, Dispatch Of Medium Voltage Cables , Group 1 Power Cables: Stranded Aluminium Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls) , 3C X 35 Sq. Mm (A2xfy) , 3C X 50 Sq. Mm (A2xfy) , 3C X 70 Sq. Mm (A2xfy) , 3C X 95 Sq. Mm (A2xfy) , 3C X 120 Sq. Mm (A2xfy) , 3C X 150 Sq. Mm (A2xfy) , 3C X 185 Sq. Mm (A2xfy) , 3C X 240 Sq. Mm (A2xfy) , 3C X 300 Sq. Mm (A2xfy) , 4C X 25 Sq. Mm (A2xfy) , 4C X 35 Sq. Mm (A2xfy) , 4C X 50 Sq. Mm (A2xfy) , 4C X 70 Sq. Mm (A2xfy) , 4C X 95 Sq. Mm (A2xfy) , 4C X 120 Sq. Mm (A2xfy) , 4C X 150 Sq. Mm (A2xfy) , 4C X 185 Sq. Mm (A2xfy) , 4C X 240 Sq. Mm (A2xfy) , 4C X 300 Sq. Mm (A2xfy) , 1C X 630 Sq. Mm (A2xway) , Group 2 Power Cables: (Fire Resitant) Fire Survival Cable, Stranded Copper, Epr Insulated Or Equivalent Material With Glass Mica Tape Insulation, Armoured, Inner And Outer Sheath As Per Relevant Iec Standards (A) The Insulation Shall Be Of Epr Or Equivalent Material With Glass Mica Tape Below Or Above Insulation. (B) Unless Otherwise Specified The Cables Shall Meet Requirement Of Circuit Integrity Test For A Minimum Period Of 3 Hours At Max. Temperature Of 950°C. , 4C X 2.5 Sq. Mm (2Xwy) -- For Mov , 12C X 2.5 Mm2 : E4-0.6/1.1-Mcxcx(C)-2.5(12C)Nk (For Rxrg Contractor) , 19C X 2.5 Mm2 : E4-0.6/1.1-Mcxcx(C)-2.5(19C)Nk (For Rxrg Contractor) , Group 3 Power & Control Cables: Stranded Copper Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls) , 3C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Tcoco(I/C)-1.5(3C)B : (For Rxrg Contractor) , 5C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Mcoco(I/C)-1.5(5C)K : (For Rxrg Contractor) , 10C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Mcoco(I/C)-1.5(10C)K : (For Rxrg Contractor) , 12C X 1.5 Sq. Mm (2Xwy) : E3-0.6/1.1-Mcoco(I/C)-1.5(12C)K : (For Rxrg Contractor) , 3C X 2.5 Sq. Mm (2Xwy) , 3C X 4 Sq. Mm (2Xwy) , 3C X 6 Sq. Mm (2Xwy) , 3C X 10 Sq. Mm (2Xwy) , 3C X 16 Sq. Mm (2Xfy) , 3C X 25 Sq. Mm (2Xfy) , 3C X 35 Sq. Mm (2Xfy) , 3C X 50 Sq. Mm (2Xfy) , 3C X 70 Sq. Mm (2Xfy) , 3C X 95 Sq. Mm (2Xfy) , 3C X 120 Sq. Mm (2Xfy) , 3C X 150 Sq. Mm (2Xfy) , 3C X 240 Sq. Mm (2Xfy) , 3C X 300 Sq. Mm (2Xfy) , 1C X 630 Sq. Mm (2Xway) , 4C X 2.5 Sq. Mm (2Xwy) , 4C X 4 Sq. Mm (2Xwy) , 4C X 6 Sq. Mm (2Xwy) , 4C X 10 Sq. Mm (2Xwy) , 4C X 16 Sq. Mm (2Xwy) , 5C X 2.5 Sq. Mm (2Xwy) , 7C X 2.5 Sq. Mm (2Xwy) , 8C X 2.5 Sq. Mm (2Xwy) , 10C X 2.5 Sq. Mm ## , 12C X 2.5 Sq. Mm ## , 14C X 2.5 Sq. Mm ## , 12C X 2.5 Sq. Mm ##: E3-0.6/1.1-Mcoco(C)-2.5(12C)Nk - (For Rxrg Contractor) , 16C X 2.5 Sq. Mm ## , 19C X 2.5 Sq. Mm ## : E3-0.6/1.1-Mcoco(C)-2.5(19C)Nk - (For Rxrg Contractor) , Group 4 Lighting Cables: Stranded Copper Conductor, Extruded Xlpe Insulation, Extruded Pvc Inner Sheath, Armoured, Overall Pvc Outer Sheath (Frls : Red, Black & Green) , 3C X 2.5 Sq. Mm (2Xwy) , 3C X 16 Sq. Mm (2Xfy) , 3C X 4 Sq. Mm (2Xwy). Last date of submission for this tender is 2026-09-08. This is a Cable Supply tender in Golaghat, Assam
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
2 issued- Tender Document 1htmlHTML document
- Tender Document 2pdfPDF document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free