🎉 Your free trial plan has started. Plan will expire in 0 days

Military Engineer Services

missamari, assam

AOC value
₹14.57L
AOC date
14 Nov
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. 14 Nov 22AOC date

Important info

Result ID
Refer Docs
Award of contract
14/11/2022
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Military Engineer Services has published Provision Of01x250 Kva Transformer At Missamari - Excavation In Trenches Not Exc 1.5 Metre Wide And Not Exc 1.5 Metre Depth For Laying Of Ug Cable / Pole Etc Getting Out Including Forming Bottom Surfaceto Required Level And Gradient In Soft / Loose Soil Complete All As Specified And As Directed. 2 Returning And Filling In Excavated Soil Including Spreading Leveling, Watering, Well Ramming In Layers Not Exc 25 Cm Thick Complete All As Specified And As Directed. 3 Removing Of Excavated Materials Not Exceeding 50 Metre And Depositing Where Directed By Engrin Charge At A Level Not Exceeding 1.5 Metre Above The Starting Point Complete All As Specified And As Directed. 4 Supply And Laying Well Burnt Bricks , Locally Available Best Quality ( Sub Class B Bricks ) Laid In Trenches Perpandicular To U / G Cable For Cable Protection Complete All As Specified And As Directed. 5 M&L Clean Dry River Sandin Trenches / Ducts For Cushioning To Cable, 8 Cm In Depth Before Laying The Cable And 15 Cm In Depth After Laying The Cable Complete All As Specified And As Directed. 6 Supply, Install, Test And Commission Step Down Transformer, Outdoor Type, Plinth Mounted Ht 11 Kv, 3 Phase 433 Volts, 4 Wire, 50 Hz, Delta / Starconnected, Vector Group Dyn -11 Double Copper Wound, Onan, Manual Type Off Load Tap Changing Facility On Ht Side To Vary Secondary Voltage From Minus 7.5% To Plus 7.5% In Steps Of 2.5 %, Continuous Rating, Level-02 Of Capacity 250 Kva Incl Bushingon Ht End Cable Box On Lt Side. The Transformer Shall Be Complete With All Standard Fittings And Accessories, Gauges, First Fill Of Transformer Oil, Etc, And Conforming To Is 1180 Part-1:2014Duly Mounted On Plinth And All As Specified And As Directed. ( A ) Oil Conservator With Filling Hole, Cap And Drain Plug ( B ) Silica Gel Breather With Oil Seal And First Fills Of Dehydrating Agent ( C ) Adequate Nos Of Thermometer Pockets Incl One No For Accomodating Bulb Type Thermometer ( D ) Drain Cum Bottom Filter Valve ( E ) Top Filter Valve ( F ) Prisomatic Oil Level Gauge ( G ) Inspection Cover ( H ) Cover Fitting Lugs ( J ) Jacking And Fitting Lugs ( K ) Separate Neutral Bushing Brought Out For Earthing On Lv Side ( L ) Earthing Terminalnote: Pcc Platform / Plinth For Placing Transformer Is Not Included In The Quoted Rate And Will Be Measured And Paid Under Seperate Item. 7 Supply & Laying, Testing & Commissioning Of Lt Ug Cable Xlpe Sheathed Pvc Insulated, Screened Pvc Bedded, Galvanised Steel Strip Of Wire Armoured Electric Power Cable Heavy Duty With Stranded Aluminium Conductor 1100 Volts Grade, Laid In Trenches, In Gi Pipe , Including Brass Cable Glands, Clamps Etc Of Size3.5 Core X 400Sq Mm Complete All As Specified.Note : Earthwork, Sand Cushioning, Bricks, Gi Pipe, Etc Will Be Measured And Paid Under Appropriate Items 8 M&L For Earthing Complete With Gi Earth Electrode 600Mmx600mmx6mm Thick Buried Directly In Ground Vertically To A Depth Not Less 2.25 Mtr Below Ground Level With Top Edge Of Earth Plate A Depth Not Less Than 1.50 Mtr Below Normal Ground Level Connection To Gistrip32x6 Mm Drawn Through And Including Galvanised Iron Protection Pipe 40 Mm Bore ( Dia ) Light Grade Up To Height Of The Transformer Foundationwhere Foundation Situated By Means Of Bolt Nuts Check Nuts And Washers Etc Earth Platesurroumded By A Packed Thickness Of Charcoal Or Coke Dust Mixedwith Common Salt In Alternatelayers Of Not Exc 150 Mm Thick Pcc Pit In Cement Concreate 1:3:6 ( 20Mm Graded Aggreage ) Pre Cast Rcc 1:2:4 ( 20 Mm Graded Aggreagate Cover Slab 350X350x50mm Thick Reinforce With Including 8Mm Dia Tmt Bars@10 Cm Centre To Centre Both Ways Gi Wire Mess, Funnel With Gi Watering Pipe 20 Mm Bore Diamedium Grade Necessary Excavation In Soft Loose Soil Returning Fillingin And Revoal Of Surplus Soil Upto A Distance Of 50 Mtr And All As Shown In Electrical Plate No 3 Of Mes Schedule Part -I And Testingon Completion Complete All As Specified And As Directed. Note:- 02 Nos For Transformer Body And 02 Nos For Main Lt Panel. 9 M&L For Earthing Complete With Gi Earth Electrode 600Mmx600mmx6mm Thick Buried Directly In Ground Vertically To A Depth Not Less 2.25 Mtr Below Ground Level With Top Edge Of Earth Plate A Depth Not Less Than 1.50 Mtr Below Normal Ground Level Connection To Galvanised Iron As Earth Lead 4Mm Dia Drawn Through And Including Galvanised Iron Protection Pipe 15 Mm Bore ( Dia ) Light Grade Up To 1 .0 Mtr Above The Ground Level Of Ht Pole Foundation Where Pcc Polesituated By Means Of Bolt Nuts Check Nuts And Washers Etc Earth Platesurroumded By A Packed Thickness Of Charcoal Or Coke Dust Mixedwith Common Salt In Alternatelayers Of Not Exc 150 Mm Thick Pcc Pit In Cement Concreate 1:3:6 ( 20Mm Graded Aggreage ) Pre Cast Rcc 1:2:4 ( 20 Mm Graded Aggreagate Cover Slab 350X350x50mm Thick Reinforce With Including 8Mm Dia Tmt Bars@10 Cm Centre To Centre Both Ways Gi Wire Mess, Funnel With Gi Watering Pipe 20 Mm Bore Diamedium Grade Necessary Excavation In Soft Loose Soil Returning Fillingin And Revoal Of Surplus Soil Upto A Distance Of 50 Mtr And All As Shown In Electrical Plate No 3 Of Mes Schedule Part -I And Testingon Completion Complete All As Specified And As Directed. 10 M&L For Earthing Complete With Copperearth Electrode 600Mmx600mmx6mm Thick Buried Directly In Ground Vertically To A Depth Not Less 2.25 Mtr Below Ground Level With Top Edge Of Earth Plate A Depth Not Less Than 1.50 Mtr Below Normal Ground Level Connection To Copper Strip20x3 Mm Drawn Through And Including Galvanised Iron Protection Pipe 40 Mm Bore ( Dia ) Light Grade Up To Height Of The Transformer Foundationwhere Foundation Situated By Means Of Bolt Nuts Check Nuts And Washers Etc Earth Platesurroumded By A Packed Thickness Of Charcoal Or Coke Dust Mixedwith Common Salt In Alternatelayers Of Not Exc 150 Mm Thick Pcc Pit In Cement Concreate 1:3:6 ( 20Mm Graded Aggreage ) Pre Cast Rcc 1:2:4 ( 20 Mm Graded Aggreagate Cover Slab 350X350x50mm Thick Reinforce With Including 8Mm Dia Tmt Bars@10 Cm Centre To Centre Both Ways Gi Wire Mess, Funnel With Gi Watering Pipe 20 Mm Bore Diamedium Grade Necessary Excavation In Soft Loose Soil Returning Fillingin And Revoal Of Surplus Soil Upto A Distance Of 50 Mtr And All As Shown In Electrical Plate No 3 Of Mes Schedule Part -I And Testingon Completion Complete All As Specified And As Directed. 11 M&L Test Point Terminal Block Made Of Gun Metal Or Phosphorus Bronze Size 75X75x25mmdnilled And Screwed Including 3 Nos 8 Mm Dia 25Mm Long Hex Head Screw Complete All As Specified And Directed By Engr-In-Charge 12 Surface Dressing In Soft Loose Soil N Exc 15 Cm Deep And Getting Out Complete All As Specified And As Directed. 13 M&L For Cement Concrete 1:4:8 ( 40Mm Graded Aggregate ) As Lean Concrete In Foundation Of Poles, Stay Assembly, Etc., Including Formwork ( As / If Required ) , Complete All As Specified And As Directed. 14 M&L Forpcc ( 1:4:8 ) Type D-2 ( Using 40 Mm Aggregate ) As In Foundation For Pole Etc.Complete All As Specified And As Directed. 15 M&L Forpcc ( 1:2:4 ) Type B-1 ( Using 20 Mm Aggregate ) As In Coping Of Pole, Top Surface Of Transformer Foundation Etc Including Form Work & Finishing The Surfaces Even & Smooth With Out Using Extra Cement Complete All As Specified And As Directed. 16 M&L For Anti-Climbing Device Comprising 2.24Mm Dia Galvanised Steel 2 Strand Barbed Wire With 2.24 Mm Dia Barbs Wrapped Spirally Round Poles, To A Length Of 5 To 1.0 Mtr Clamed And Properly Secured Or As Ordered Clamps Measured Separately 17 M&L For Brick Work With Burnt Old Size Bricks Built In Cement Mortar 1:6 Straight Or Curved On Plan Exceeding 6Mtr Mean Radius And All As Directed. 18 M&L For Rendering 15 Mm Thick On Other Than Fair Faces Of Brick Or Concrete Surfaces In Cement Mortar 1:6 Finished Even And Smooth Complete All As Specified And As Directed. 19 M&L For Hardcore Of Gauge N Exc. 63 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface For Footpath Andstone Aggregate Around Perimeter Of Transformer Fondation Complete All As Specified And As Directed. 20 M&L For Cement Concrete 100 Mm Thick Type C-2, 1:3:6 ( 40Mm Graded Aggregate ) For Footpath Complete All As Specified And As Directed. 21 M&L For Cement Concrete 40 Mmthick Type C-2, 1:2:4 ( 40Mm Graded Aggregate ) For Footpath Complete All As Specified And As Directed. 22 M&L For Hardcore Of Gauge N Exc. 100 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface For Stone Aggregate Around Perimeter Of Transformer Foundation Complete All As Specified And As Directed. 23 M&L For Three Coat Ofwhite Wash Onwall Surface Including Preparation Of Surface Complete All As Specified And As Directed.. Last date of submission for this tender is 2022-10-28. This is a Coats And Jackets tender in Missamari, Assam

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

1 issued
  • Tender Document 1html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in