🎉 Your free trial plan has started. Plan will expire in 0 days

Indian Army

151 base hospital, assam

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Authority
Indian Army
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Indian Army has published Procurement Of Consumables -Titanium Elastic Nails With Locking End Caps. ( Complete Range Of Size And Side Specific Implant With Instrumentation At The Time Of Surgery. Implant Should Be Us Fda / Eu-Ce / Bis Standard Compliant ) Manufacturer Must Have Manufacturing Licence On Form 9 By Cdseo, Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified, , Interlocking Cannulated Anatomical Femoral Nails ( Trochantric Entry ) ( 5-& Degrees Proximal Offset ) Right And Left With Option Of Gt To Lt Locking / Transverse Locking With 4X 5 / 4.9 Mm Locking Bolts, 11 Mm Dia , 440Mm Length And End Cap Titanium- Comnplete Construct. Implants Should Be Usfda And Ce Certified , Styker Interlocking Nail For Tibia ( Titanium ) 8 And 9 Mm Dia Of Assorted Size With 04 Locking Bolts ( Instrument To Be Part With Supply Of Nail ) Manufacturer Must Have Manufacturing Licence On Form 9 By Cdseo, Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified, Lcp Distal Fibular Plate Right / Left 4-10 Hole, Titanium With 6 Locking Screws Size Mm ( 14-18 ) , Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified, Distal Femur Variable Angle Locking Plate ( Titanium ) , ( Various Sizes ) Right / Left, With10x Locking Screws, Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified Titanium Lcp Distal Medial Tibia Plate 4 Hole, With 4 Locking Screws Size Mm ( 26-44 ) , Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified Titanium Lcp Distal Femur, Left / Right Plate 5 Hole With Locking Screws For All Holes, Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified Titanium 3.5Mm Proximal Lateral Tibial Lcp, 6 Hole Left / Right With All Locking Screws , Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified Hto Plate ( Puddu Type ) Size7.5 Mm With 4Bolt, Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified Femur Ostiotomy Plate With All Size & Screws, Manufacturer Should Be Certified By Indian Fda , Iso 13485.2016 And European Ce, Items Must Be Bis / European Ce / Usfda Certified Ao Pattern Cortical Screws, 4.5Mm Dia, Self Tapping, Lengths 18 To 80 Mm, Material- 316Lvm Stainless Steel, Should Be Mri Safe. Ao Pattern Cortical Screws 3.5Mm Dia, Self Tapping, Lengths 10 To 70 Mm Titanium. Ao Pattern Locking Head Screws 3.5Mm Dia, Self Tapping, Lengths 10 To 90 Mm Titanium, Should Be Mri Safe. Uncemented Thr Set Consisting Of Uncemented Beaded Porous Coated Acetabular Cup With Three Screw Holes ( 50 / 52 / 54, Mm, ) Highly Crosslinked Polyethylene Liner ( 50 / 32 Mm ) , Uncemented Femoral Stem With Lateral Offset Option, 12 / 14 Taper And Low Profile Lateral Shoulder ( Proximally Circumferentially Porous Coated ) , Delta Ceramic Head ( 32Mm ) , Three Acetabular Screws Ceramic On Poly Uncemented Thr Implant With 36Mm Head ( Ceramic ) &Highly Cross-Linked Poly Liner With 3 Acetabular Screws With 4 Warp Around Surgical Gowns And A Pulsatile Jet Lavage System. Metal On Poly Dual Mobility ( Tripolar ) Uncemented Thr Implant With Highly Cross Linked Poly Liner With 3 Acetabular Screws With 4 Wrap Around Surgical Gowns And A Pulsatile Jet Lavage System Uncemented Thr Set Consisting Of Uncemented Porous Coated Acetabular Cup ( 52 Mm ) With Monobloc / Integrated Delta Ceramic Liner, Uncemented Femoral Stem With Lateral Offset Option, 12 / 14 Taper And Low Profile Lateral Shoulder ( Proximally Circumferentially Porous Coated ) , Delta Ceramic Head ( 36Mm ) Posterior Stabilized Fixed Bearing Tkr Implant With Augmentable Tibia , Co Cr Femur, Moderately Crosslinked Articular Insert To Be Supplied With Straight And Offset Stem Posterior Stabilised Fixed Bearing Knee With Symmetric Tibia Consisting Of : Cobalt Chromium Femoral Component, Matching Polyethylene Fixed Ps Insert And Modular Symmetric Tibial Base Plate Compatible With Stem. ( All Implant Sizes With Compatible Instrumentation, One 40 Gm Packet Of Antibiotic Cement And Saw System To Be Provided At The Time Of Surgery, Implant Should Have Registry Follow Up Data / Odep Rating. Usfda Approved / Eu-Ce Certified ) . Last date of submission for this tender is 2021-12-30. This is a Cutting Crimping And Punching Tools tender in 151 Base Hospital, Assam

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

3 issued
  • Tender Document 1pdf
  • Tender Document 2pdf
  • Tender Document 3html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in