🎉 Your free trial plan has started. Plan will expire in 0 days

Indian Army

likabali, assam

AOC value
Refer Docs
AOC date
Refer Docs
Completion
Refer Docs
L1 bid
Refer Docs

Timeline

  1. -Published
  2. -Closes
  3. -Bid opens
  4. -AOC date

Important info

Result ID
Refer Docs
Award of contract
Refer Docs
Authority
Indian Army
Published
Refer Docs
Tender closed
Refer Docs
Tender no
Bidding URL
Tender
Bidder details

AOC description

Indian Army has published Supply And Construction Of 01 Nos Pl Idl; 2 Supply & Constr of PDs (RCC) of internal size 2.50m x 2.50m x 2.10m and 250mm RCC wall, 250mm RCC slab, 150mm PCC flooring in 2 layers & 300mm OHP. PDs consist of a fighting bay with one door and threeloop holes as per drg att. Tech specification as per Appx A and store details as per Annx-I & II. 3 Supply & Constr of MMG Bunker of size 2.40m x 2.40m x 2.10m and 300mm RCC wall, 250mm RCC slab, 150mm PCC flooring in 2 layers & 300mm OHP with one door and two loop holes as per drgs att.Tech specification as per Appx B and store details as per Annx-III & IV. 4 Supply & Constr of Amn PD of size 3.00 x 2.00 x 2.40m clear internal Height and 300mm thick RCC wall, 250mm thick RCC Slab with 25mm PCC over APP Membrane, 150mm PCC flooring in 2 layers, 300mm OHP and one door as per drgs att. Detailed tech specification are as per Appx Catt and store list as per Annx - V & VI. 5 Supply & Constr of RL Trench of size 1432mmx1242mm with trapezoidal ends, open from top and RCC wall of 200mm thick as shown in drawing. Flooring would be of 100mm thick PCC over 100mm thick hardcore, 2mm MS Shutter lid of size 1900x1700mm fabiracted out of MS Angle for cover to be provided. Tech specification as per Appx D and store details as per Annx-VII & VIII. 6 Supply & Constr of Svl Bunker, framed structure will be 300mm thick RCC wall, 250mm thick RCC roof with 50mm thick PCC over polythene bitumen membrane, 140mm PCC flooring in 2 layers, 300mm OHP and one door and three loop holes as shown in drawing.Internal dimensions of Svl Bunker will be 5.40 x 2.40 x 2.50m and entrance/exit area 1200x 1200x2500mm as per detailed technical specifications att as Appx E and store details as per Annx - IX & X. 7 Supply & Constr of Cook House PD of size 5.40 x 2.40 x 2.50m and 300mm thick RCC wall, 250mm thick RCC Slabwith 25mm PCC over APP Membarane, 140mm PCC flooring in 2 layers, 300mm OHP, Staging for water storage tank of size 1.35m x 2.40 m x 4.50m height, three doors and four loop holes/ventilators. Detailed tech specification are as per Appx Fatt and store list as per Annx - XI &XII. 8 Supply & Constr of Toilet Cum Bathroom of size 3.00 x 2.00 x 2.40mand 300mm thick RCC wall, 250mm thick RCC Slabwith 25mm PCC over APP Membarane, Non skid ceramic tiles flooring, 300mm OHP, Staging for water storage tank of size 1.35m x 2.40 m x 4.50m height and two doors . Detailed tech specification are as per Appx Gatt and store list as per Annx - XIII & XIV. 9 Supply & Installation of Gen Set 15 KVACPCB IV+ compliantGenset , efficient CRDI system 02E Series : low emission , high efficiency engine. Tech specificationsas per Appx ‘A’ and store list as per Annx-XV. The Diesel Generator Set shall be supplied with a warranty of 2 year. Genr Set should be covered with PPGI roof sheet having PCC plinth. Detailed tech specification are as per Appx HattNOTE: (i)Initial testing done by the supplier at consignee FOR and cost of the effect is deemed to be included in quoted rate of the Genr Set. Warranty:- TheSupplier will give free warranty for engine, alternator, self batteries, control panel and remaining accesories for a period of minimum 24 months from the date ofsupply, for generator which do not require commissioning or for a period of minimum one year from the date of commissioningand succesful testing , for generator which require commissioning , whichever is later. 10 Supply & Constr of Comn Trench of size 1.0 x 2.0m and 150mm thick RCC wall & 150mm thick RCC Slab. Tech Specification given in Appx J and all dimensions as per drg. Store List att as per Annx- XVI . 11 2 HP single phase Monoblock Pumps cast iron Body with Bronze Impeller Single Phase 230V,5HP , Head 38-50 m discharge of water 350 ltr/min (Make : CRI / Crompton Greaves / Kirloskar) 12 Starter for 2 HP Pump set build in MS sheet enclosure (Make of starter: Havells / L&T / Bajaj) 13 Supply & Constr of Fd Water Supply Scheme (FWSS). Detailed specification as per Appx K and store list incl constr mtrl att as per Annx - XVII. 14 (i) XLPE insulated, PVC tape inner sheathed, armoured, heavy duty underground, electric cable conforming to IS 7098 (Part-I) 1988 with standard aluminium conductor, cross sectional area 25 Sqmm, 4 core, 1100 volt grade . Make : Gloster / Plaza / Paragon / Havells / Finolex / CCI / RR Kabel. 15 (ii)Change over switch 63 Amp Tp (Make :Havells/Siemens/Indo Asian) 16 (iii) PVC indulated, heavy duty, 1100 volt grade cable with aluminium conductor, twin core, 10 sqmm served with sheathing of PVC tape and overall PVC sheathed, flat or circular. 17 (iv)Pedestal fan 400mm sweep with 3 blades as specified and approved. . Last date of submission for this tender is 2024-10-04. This is a Tanks And Cylinders tender in Likabali, Assam

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

4 issued
  • Tender Document 1html
  • Tender Document 2xlsx
  • Tender Document 3pdf
  • Tender Document 4pdf
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in