Assam University has published 24X7 Operation And Maintenance Contract For 2X2.5 Mva, 33/11 Kv Dedicated Substation, At Assam University, Silchar.; 2 AMC for 33/11 kV substation shall include operation and maintenance of VCB, CR panel, battery charger, post isolators, power transformers through trained staff including cleaning of vegetation as per requirement inside the 33 kV substation area and around the fencing complete. The works shall require the execution of all the works included in the technical specification complete and as directed by the department. 3 PART - B 4 SITC of 33KV ,10kA LA Line type (APDCL approved makes) 5 SITC 33 KV pin insulator (Porcelain)(APDCL approved makes) 6 SITC 33 KV polymeric Disc Insulator 90kN (APDCL approved makes) 7 SITC 33 KV Isolator Post insulator (Porcelain)(APDCL approved makes) 8 SITC 11 KV Isolator Post insulator (Porcelain)(APDCL approved makes) 9 Supplying, installation testing and commissioning of 11 KV outdoor CT with marshalling box andGI mounting structure with connector 200-100/5-5A(set comprising of three units)as directed by department and as per the technical specification of APDCL complete. 10 SITC of 11 KV disc insulator(70KN)porcelain 11 SITC of 11 KV post insulator porcelain 12 SITC of 11 KV pin insulator polymeric 13 SITC of 11 KV , 10KA, Station type, Class-2 14 SITC of 11 KV , 5KA LA line type, Distribution class 15 Supplying, installation testing and commissioning of control cable copper 7 core X 2.5 sqmmas directed by department and as per the technical specification of APDCL complete. 16 Supplying, installation testing and commissioning of control cable copper 4 core X 2.5 sqmmas directed by department and as per the technical specification of APDCL complete. 17 Supplying fitting and fixing of transformer bushing for 33/11 KV,1X 2.5 MVA existing power transformer. 18 Heat curing and tanking of transformer for 33/11 KV,1X 2.5 MVA existing power transformer. 19 Oil filter and filling after dehydration of transformer for 33/11 KV,1X 2.5 MVA existing power transformer. 20 Supplying fitting and fixing of transformer new gasket set complete for 33/11 KV,1X 2.5 MVA existing power transformer. 21 Cleaning, painting, varnishing of transformer tank both inside and outside for 33/11 KV,1X 2.5 MVA existing power transformer. 22 Supplying and fitting fixing of 33 KV V Cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department.(channel size 100x50x6mm) 23 Supply fitting fixing of GI strip 50x6mm for DTR neutral 24 Supply fitting fixing of HT Stay sey 25 Supply fitting fixing of GI nuts and bolts assorted 26 Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department. 27 33 KVA Breaker Overhaulingas per standards of APDCL and as directed. 28 Supply fitting & fixing of Overcurrent / Earth fault relay as per standards of APDCL and as directed. 29 Supply fitting & fixing of Master trip relayas per standards of APDCL and as directed. 30 33 KV CT Overhaulingas per standards of APDCL and as directed. 31 Transformer Filtrationas per standards of APDCL and as directed. 32 Transformer Testing and commissioning completeas per standards of APDCL and as directed. 33 Supply of Transformer Oil complete as required and directed. 34 Repairing of 2.5 MVA marshalling box (Master control panel for protection ) along with supply of newWTI, OTIcomplete with wiring done to indoor CR panel for protection indication complete as directed by department. 35 Repairing of existing bucholz relay complete with wiring done to indoor CR panel for protection indication complete as directed by department 36 SITC of silica gel breather for 2.5 MVA power transformers 37 Oil temperature gauge for 2.5 MVA power transformers 38 7 Segment 4 digit LED display CR panel single phase Ammeter. 39 7 Segment 4 digit LED display CR panel single phase Voltmeter. 40 4 pole contactor with AC/DC coil with power poles. 41 12V ,100 AH battery for CR panel DC power supply. 42 Any other SOR item based on APDCL SOR. . Last date of submission for this tender is 2025-11-17. This is a Substation tender in Silchar, Assam

Free up your BG limit

Cover your EMD without touching your bank limit.

Get a quote
Tenderbook Surety

Documents

2 issued
  • Tender Document 1pdf
  • Tender Document 2html
lock-red

Unlock the Tender details for free

Bidder Details

  • Technical: clearedFinancial: clearedAOC: cleared
    Bid value
  • Technical: clearedFinancial: clearedAOC: not cleared
    Bid value
  • Technical: clearedFinancial: not clearedAOC: not cleared
    Bid value
  • Technical: not clearedFinancial: not clearedAOC: not cleared
    Bid value
lock-red

Unlock the Tender details for free

Disclaimer: Tenderbook takes every possible care to ensure the accuracy and authenticity of the tender information published on the platform. However, users are requested to verify the details from the original Tender Notice or Tender Document issued by the respective tendering authority before making any decisions or taking action related to a tender. We are not liable for any loss or damages arising from its use. For any corrections or feedback, connect with us at contact@tenderbook.in