Department Of Defence Production
- AOC value
- ₹58.92L
- AOC date
- Refer Docs
- Completion
- Refer Docs
- L1 bid
- Refer Docs
Timeline
- -Published
- -Closes
- -Bid opens
- -AOC date
- -Published
- -Closes
- -Bid opens
- -AOC date
Important info
- Result ID
- Refer Docs
- Award of contract
- Refer Docs
- Authority
- Department Of Defence Production
- Published
- Refer Docs
- Tender closed
- Refer Docs
- Tender no
- Bidding URL
- Tender
- Bidder details
AOC description
Department Of Defence Production has published Bids Are Invited For Supply Of Ht 11Kv - Supply Of Ht 11Kv ( E ) Cable Of Size 3Core 400Sq.Mm Aluminium Conductor Xlpe Insulated Earthed Armoured Sheathed Cable. Cable Conforming To Is 7098 ( Part-2 ) – 2011 As Amended Up To Date And As Per The Given Specification ( Make : Polycab, Havells, Gloster ) , Supply Of 1.1Kv Cable - Supply Of 1.1Kv Cable Of Size 3.5 Core 50 Sq.Mm Aluminium Conductor Xlpe Insulated Earthed Armoured Sheathed Cable. Cable Conforming To Is 7098 Part-I As Amended Up To Date And As Per The Given Specification ( Make : Polycab, Havells, Gloster ) , Breaking Of Existing Concrete And Excavate The Cable Trench - Breaking Of Existing Concrete And Excavate The Cable Trench Upto 1.2Meter Depth 600Mm Width, Provide Sand Of 75Mm Thick, Lay The 1 Run Of 3Core 400Sq.Mm Ht 11Kv Cable And 1 Run Of 3.5 X 50Sq.Mm Cable, Put The Bricks Between Two Cables For Separation, Put The Precast Rcc Slabs On The Cable, Provide Red Tape, Refill The Trench With Soil And Provide The Concrete. Top Level Of This Concrete To Be Matched With The Existing Level Including Watering For Concrete , Excavate The Cable Trench On Black Top Road - Excavate The Cable Trench On Black Top Road Upto 1.2Meter Depth 600Mm Width, Provide Sand Of 75Mm Thick, Lay The 1 Run Of 3Core 400Sq.Mm Ht 11Kv Cable And 1 Run Of 3.5 X 50Sq.Mm Cable, Put The Bricks Between Two Cables For Separation, Put The Precast Rcc Slabs On The Cable, Provide Red Tape, Refill The Trench With Soil, Consolidate Thouroughly, Provide Concrete ( 100 Mm Thick ) And Provide Top Layer Bt Road ( 50 Mm Thick ) To Match The Existing Black Top Road Surface Using Power Roller Of Minimum 10T Capacity. , Clear The Site By Removal Of All Furs And Small Trees In The Cable Route, - Clear The Site By Removal Of All Furs And Small Trees In The Cable Route, Excavate The Cable Trench Upto 1.2Meter Depth 600Mm Width, Provide Sand Of 75Mm Thick, Lay The 1 Run Of 3Core 400Sq.Mm Ht 11Kv Cable And 1 Run Of 3.5 X 50Sq.Mm Cable, Put The Bricks Between Two Cables For Separation, Put The Precast Rcc Slabs On The Cable, Provide Red Tape, Refill The Trench With Soil. Top Level To Be Matched With The Existing Level. , Lay, Test And Commissioning - Lay, Test And Commissioning Of 3 Core 400Sq.Mm 11Kv Ht Cable In Existing Cable Trench / Through Gi Pipes / Culverts All As Directed And As Specified. , Lay, Test And Commissioning. - Lay, Test And Commissioning Of 3.5 Core 50Sq.Mm 1.1Kv Lt Cable In Existing Cable Trench / Through Gi Pipes / Culverts All As Directed And As Specified , Supply Of 3Core 400Sq.Mm Ht Cable 11Kv End Joint Of Heat Shrinkable With Necessary Lugs Etc. ( Make : 3M, Rpg Rechyem, Dension ) - Supply Of 3Core 400Sq.Mm Ht Cable 11Kv End Joint Of Heat Shrinkable With Necessary Lugs Etc. ( Make : 3M, Rpg Rechyem, Dension ) , Fixing Of 3Core 400Sq.Mm Ht Cable - Fixing Of 3Core 400Sq.Mm Ht Cable 11Kv End Joint Of Heat Shrinkable With Necessary Lugs Etc. And Termination Of The Cable At Both Ends , Supply Of 150Mm Dia. - Supply Of 150Mm Dia. Gi Pipes Medium ( B Class ) With Necessary Angle Supports, Suitable Size Clamps Fixed With Nut & Bolts Including Necessary Joint. , Laying Of 150Mm Dia - Laying Of 150Mm Dia. Gi Pipes Medium ( B Class ) In Existing Cable Trench Or On Culvert Crossing With Necessary Angle Supports And Suitable Size Clamps Fixed With Nut & Bolts Including Necessary Joint. , Supply Of 50Mm Dia Gi Pipes - Supply Of 50Mm Dia Gi Pipes Medium ( B Class ) With Necessary Angle Supports To Wall Fixing The Clamps With Nut & Bolts Including Necessary Joint. , Laying Of 50Mm Dia Gi Pipes - Laying Of 50Mm Dia Gi Pipes Medium ( B Class ) In Existing Cable Trench Or On Culvert Crossing With Necessary Angle Supports To Wall Fixing The Clamps With Nut & Bolts Including Necessary Joint. , Preparation Of Precast Rcc Concrete Slabs - Preparation Of Precast Rcc Concrete Slabs With 1:2:4 Concrete Of Size 500Mm X 600Mm X 50Mm For Cable Protection Including Watering, Grove Type Lettering As Hsl Ht Cable On Slabs , Providing Suitable Rcc Beam - Providing Suitable Rcc Beam Across The Am Drain To Support The Cable / Pipe Sleeve Crossing Including All Material & Labour. , Cleaning Of Drain Including Removal Of All Debris - Cleaning Of Drain Including Removal Of All Debris, Small Plants, Mud Etc. With Machinery Or Manpower. Dispose It To Outside The Town Area With Lorries. Total Quantity : 1. Last date of submission for this tender is 2022-02-16. This is a Bolts tender in Visakhapatnam, Andhra Pradesh
Free up your BG limit
Cover your EMD without touching your bank limit.
Get a quoteDocuments
1 issued- Tender Document 1htmlHTML document
Unlock the Tender details for free
Bidder Details
- Technical: clearedFinancial: clearedAOC: clearedBid value
- Technical: clearedFinancial: clearedAOC: not clearedBid value
- Technical: clearedFinancial: not clearedAOC: not clearedBid value
- Technical: not clearedFinancial: not clearedAOC: not clearedBid value
Unlock the Tender details for free